Loading...
Valley R Plaza 2B-LR030731CONCRETE COMPRESSIVE STRENGTH TEST IDC Report Number: 5 1(erraeon Service Date: Jul 3, 2003 8901 Carpenter Frwy, Ste #100 Y Dallas, Texas 75247 (214) 630 -1010 Client: Phase II BLMA Limited Report Date: July 31, 2003 Attn: Tad Weatherford Project: Valley Ranch Plaza Phase II 5950 Berkshire Ln Ste 410 817 South MacArthur Blvd Dallas TX 75225 Coppell, TX Number: 94031170 Specified Strength: 4000 psi @ 28 Days Batch Time: 12:30pm Plant: 1 Supplier: Redi -Mix Truck No: 111 Ticket No: 112045 Mix I.D. No.: 732 Water Added Onsite Before Test: 10 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,O F: Ambient Temperature, 0 F Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 2:00pm Date Cast: July 3, 2003 Technician: Wesley A. Lawson Weather Conditions: Sunny Accumulative Yards: 5 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Paving See attached sketch Result Specification 5.00 4.5 102 91 Set Specimen Diameter Area No. ID (inches) ( sq. inches 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Date Tested 07/10/2003 07/10/2003 Test Method ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 98,550 3,480 7 101.560 3,590 Average 07/31/2003 28 121,880 07/31/2003 28 123,570 Average 3,540 4,310 4,370 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Wesley A. Lawson Report Distribution: / A;rdr /gcon (1) Phase II 31-MA Limited (1) City of Coppell TX Reviewed by: (1) City of Coppell TX (1) Mycon General Contractors Senior r Cleveland, P.E. or Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 o,.uwao''F . ".v