Valley R Plaza 2B-LR030604FIELD DENSITY TESTING
Report Number: 94031170 00
Service Date: May 27, 2003
1rerr acon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630 -10
Client: Phase II BLMA Limited
Attn: Tad Weatherford
5950 Berkshire Ln Ste 410
Dallas TX 75225
Report Date: June 04, 2003
Project: Valley Ranch Plaza Phase II
817 South MacArthur Blvd
Coppell, TX
Number: 94031170
Material Information
Lab Test Data
Project Requirements
Water
Optimum
Max. Lab
Water
Mat.
Depth
Water
Dry Unit
Content
Minimum Dry
Material Laboratory
Content
Weight
Range
Unit Weight
No. Test Method Description and Classification
( %)
(pcf)
( %)
(% compaction)
1.311700001 ASTM D 698 Med to dk brown clay
20.3
101.8
-2/ +4
95
Field .Test Data
Probe
Water
Dry Unit
Dry Unit
Test Lift/
Mat.
Depth
Content
Weight
Weight
No. Test Location Elevation
No.
(inches)
( %)
(pcf)
(i compaction)
Sewer Backf ill, Entrance to Beltline
34 N bound lane Final
1
8
24.0
100.0
98
35 S bound lane Final
1
8
24.2
96.7
95
Water Line
36 Center line of drive, S of building Final
1
8
23.7
97.5
96
Comments:
Test results on this report meet project specification.
Services - Perform in -place density and moisture content tests
to determine degree of compaction and
material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Technician: Burl E. Thomas
Report Distribution: /// /racon
(1) Phase II BLMA Limited
(1) City of Coppell TX Reviewed by:
(1) City of Coppell TX AP Eric J. Cleveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 o,.soww,.r�wnx.,