ST9302-CS010709
TEXAS DEPARTIVIEN'1' OF LICF,NSING AND REGULATION
Code Review and Inspections
ARCHITECTURAL BARRIERS
P.O. Box 12157 Austin, Texas 78711 (512163-3211 (877)278-0999 FAX (512~t75-2886
Email Address: techinfo.aha(7.license.state.tx.us IntemetAddress: www.license.state.tx.us
~ `° t"`" e `~~
~~c t p{~~rn. ~ ,
. ~~",, `'
JEFF JAMES ~"'"a;?~~+ JUL-03-2001
KIMLEY HORN & ASSOC INC /~< 9
JEFF JAMES
FORTCWORTH,STXU7610211 k/M~FY.y ~~~
Re: COPPELL SANDY LAKE RD EABPRJA1008798
PAVING/DRIANAGE WATER SYSTEM-COPPELL
SANDY LAKE RD
COPPELL, TX 75019
PLANS, SIGNED AND SEALED 06/29/98; AND SPECIFICATIONS
Dear MR. JAMES
Enclosed are the results of the plan review completed on the
referenced project. Identified on the worksheet(s) are areas of
nonconformance with accessibility standards adopted by the Texas
Department of Licensing and Regulation for purposes of ensuring
compliance with Article 9102, Texas Civil Statutes.
Although nonconforming items have been noted, the referenced project
will be eligible for approval if constructed according to the
documents reviewed and as noted on the worksheet(s). Items which are
the responsibility of the owner should be referred to the appropriate
person for actipn.
This determination does not address applicability of the Americans
with Disabilities Act (ADA), (P. L. 101-336), or any other state,
local, or federal requirement. For information on the ADA, call the
ADA Hotline, (800)949-4232 or the United States Department of Justice
at (202)514-0301.
An inspection will be conducted within one year of the completion
date. The building owner will be contacted to arrange the inspection.
Please reference the EABPRJ number in all future correspondence
pertaining to this project.
:DKJ
U~
Austi Headquarters:
~ ..~1
~,~ V ~
."iN"
~y~
State Utuce ttuuamg - ylu troioraao - Ausnn, -texas
TEXAS DEPARTMENT OF LICENSING AND REGULATION
PLANS AND SPECIFICATIONS REVIEW WORKSHEET
Article 9102, T.C.S.
PROJECT: PAVING/DRAANAGE WATER SYSTEM-COPPELL
FACILITY: COPPELL SANDY LAKE RD
OWNER: CITY OF COPPELL
ARCHITECT: KIMLEY HORN & ASSOC INC
REVIEWER: JAHNS, DEBORAH K
PROJECT NO.: EABPRJA1008798
REVIEW EAB2001048169R
PAGE: 1
DATE: 07/02/01
4 ACCESSIBLE ELEMENTS AND SPACES: TECHNICAL REQUIREMENTS
**PROJECT DESCRIPTION:
CONSTRUCTION OF REINFORCED CONCRETE PAVING, CONCRETE
DRAINAGE CHANNEL, STORM DRAIN, AND WATER SYSTEM IMPROVEMENTS
THE SCOPE OF WORK ALSO INCLUDES SIDEWALKS AND CURB RAMPS.
**APPLICATION:
4.1.2 SITES AND EXTERIOR FACILITIES: NEW CONSTRUCTION
ALL "COMPLIANCE REQUIRED" ITEMS MUST BE CORRECTED PRIOR
TO INSPECTION TO BE APPROVED.
ITEMS NOTED AS "UNACCEPTABLE", WHICH PS2E BEYOND THE SCOPE
OF THE ENGINEER, SHOULD BE FORWARDED TO THE CITY OF
COPPELL FOR ACTION. CONSTRUCTION DOCUMENTS
CANNOT BE CONSIDERED APPROVED UNTIL ALL "UNACCEPTABLE"
ITEMS ARE RESOLVED.
UNACCEPTABLE 4.3 ACCESSIBLE ROUTE
4.3.7 Slope
**NOTE: To comply with 4.3.7, the slope of new sidewalks cannot
exceed 5$ in the direction of travel.
According to plans, (ie. sheet 54), the slope exceeds
5~ in some areas.
PLANS AND SPECIFICATIONS REVIEW WORKSHEET
Article 9102, T.C.S.
PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL
FACILITY: COPPELL SANDY LAKE RD
REVIEWER: JAHNS, DEBORAH K
*COMPLIANCE REQUIRED WITH 4.3.7
NOT NOTED 4.4 PROTRUDING OBJECTS
PROJECT NO.: EABPRJA1008798
REVIEW EAB2001048169R
PAGE: 2
DATE: 07/02/01
**NOTE: Ensure that trees, overhead signage, utility boxes,
fire hydrants, etc. do not protrude into the accessible
route.
4.5 GROUND AND FLOOR SURFACES
4.5.1 General
**NOTE: Unable to verify that the ground surface of the accessible
route that crosses existing streets is in compliance with
the requirements of 4.5.
*COMPLZANCE REQUIRED WITH 4.5
NOT NOTED 4.6 PARKING AND PASSENGER LOADING ZONES
UNACCEPTABLE 4.7 CURB RAMPS
4.7.2 Slope
**NOTE: Insufficient information provided to verify that the
slope of the adjoining gutters and road surface
directly adjacent to new curb ramps is no more than 2~.
*COMPLIANCE REQUIRED WITH 4.7.2
4.7.4 Surface
**NOTE: Insufficient information provided on the standard detail
sheet to verify that new curb ramps will have a texture
that does not accummulate water and is detectable under
foot, and a color that significantly contrasts with the
adjoining sidewalk and street.
*COMPLIANCE REQUIRED WITH 4.7.4
4.7.10 Diagonal Curb Ramps
**NOTE: To comply with 4.7.10, diagonal Curb ramps with flared sides
must have at least a 24" long segment of straight curb
on each side of the curb ramp.
According to the typical detail sheet, the straight segment
of curb is not provided on diagonal curb ramps.
FLANS~AND SPECIFICATIONS REVIEW WORKSHEET
Article 9102, T.C.S.
PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL
FACILITY: COPPELL SANDY LAKE RD
REVIEWER: JAHNS, DEBORAH K
PROJECT NO.: EABPRJA1008798
REVIEW EAB2001046169R
PAGE: 3
DATE: 07/02/01
*COMPLIANCE REQUIRED WITH 4.7.10
**NOTE: To comply with 4.7.10, the straight segment of curb ramp
required for diagonal curb ramps must be located within
the marked crossings.
According to plans, curb ramps at marked crossings do
not comply with this requirement.
*COMPLIANCE REQUIRED WITH 4.7.10
NOT NOTED 4. 8 RAMPS
NOT NOTED 4. 9 STAIRS
NOT NOTED 4. 10 ELEVATORS
NOT NOTED 4. 11 PLATFORM LIFTS (Wheelchair Lifts)
NOT NOTED 4. 12 WINDOWS
NOT NOTED 4. 13 DOORS
NOT NOTED 4. 14 ENTRANCES
NOT NOTED 4. 15 DRINKING FOUNTAINS AND WATER COOLERS
NOT NOTED 4. 16 WATER CLOSETS
NOT NOTED 4. 17 TOILET STALLS
NOT NOTED 4. 16 URINALS
NOT NOTED 4. 19 LAVATORIES AND MIRRORS
NOT NOTED 4. 20 BATHTUBS
NOT NOTED 4 .21 SHOWER STALLS
NOT NOTED 4. 22 TOILET ROOMS
NOT NOTED 4. 23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS
NOT NOTED 4. 24 SINKS
NOT NOTED 4. 25 STORAGE
NOT NOTED 4. 26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS
UNACCEPTABLE 4. 27 CONTROLS AND OPERATING MECHANISMS
PLANS AND SPECIFICATIONS REVIEW WORKSHEET
Article 9102, T.C.S.
PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL
FACILITY: COPPELL SANDY LAKE RD
REVIEWER: JAHNS, DEBORAH K
PROJECT NO.: EABPRJA1008798
REVIEW EAB2001048169R
PAGE: 4
DATE: 07/02/01
4.27.2 Clear Floor Space
**NOTE: To comply with 4.27.3, at least 30" x 48" of clear and
level floor space must be centered on the pedestrian
crosswalk controls.
Insufficient information is provided to verify compliance.
*COMPLIANCE REQUIRED WITH 4.27.2
4.27.3 Height
**NOTE: To comply with 4.27.3, pedestrian cro sswalk controls must
be mounted no higher than 54" AFF.
Insufficient information is provided to verify compliance
*COMPLIANCE REQUIRED WITH 4.27.3
NOT NOTED 4. 28 ALARMS
NOT NOTED 4. 29 DETECTABLE WARNINGS
NOT NOTED 4. 30 SIGNAGE
NOT NOTED 4. 31 TELEPHONES
NOT NOTED 4. 32 FIXED OR BUILT-IN SEATING AND TABLES
NOT NOTED 4. 33 ASSEMBLY AREAS
NOT NOTED 4. 34 AUTOMATED TELLER MACHINES
NOT NOTED 4. 35 DRESSING AND FITTING ROOMS
NOT NOTED 5 RESTAURANTS, CAFETERIAS, SNACK BARS, AND VENDING AREAS
5 .1 GENERAL
5 .2 COUNTERS AND BARS
5 .3 ACCESS AISLES
5 .4 DINING AREAS
5 .5 FOOD SERVICE LINES
5 .6 TABLEWARE AND CONDIMENT AREAS
P,LANS.AND SPECIFICATIONS REVIEW WORKSHEET
Article 9102, T.C.S.
PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL
FACILITY: COPPELL SANDY LAKE RD
REVIEWER: JAHNS, DEBORAH K
PROJECT NO.: EABPRJA1008798
REVIEW EAB2001046169R
PAGE: 5
DATE: 07/02/01
5.7 RAISED PLATFORMS
5.8 VENDING MACHINES AND OTHER EQUIPMENT
5.9 QUIET AREAS (Reserved)
NOT NOTED 6 MEDICAL CARE FACILITIES
6.1 GENERAL
6.2 ENTRANCES
6.3 PATIENT BEDROOMS
6.4 PATIENT TOILET ROOMS
6.5 SIZE OF AREAS OF RESCUE ASSISTANCE
6.6 INFORMATION COUNTERS AND NURSES STATIONS
NOT NOTED 7 BUSINESS AND MERCANTILE
7.1 GENERAL
7.2 SALES AND SERVICE COUNTERS, TELLER WINDOWS, INFORMATION COUNTERS
7.3 CHECK-OUT AISLES
7.4 SECURITY BOLLARDS AND TURNSTILES
NOT NOTED 8 LIBRARIES
6.1 GENERAL
8.2 READING AND STUDY AREAS
8.3 CHECK-OUT AREAS
8.4 CARD CATALOGS AND MAGAZINE DISPLAYS
8.5 STACKS
NOT NOTED 9 ACCESSIBLE TRANSIENT LODGING
9.1 HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS, ETC
9.2 REQUIREMENTS FOR ACCESSIBLE UNITS, SLEEPING ROOMS AND SUITES
9.3 VISUAL ALARMS. NOTIFICATION DEVICES AND TELEPHONES
.PL,ANS•AND SPECIFICATIONS REVIEW WORKSHEET
Article 9102, T.C.S.
PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL
FACILITY: COPPELL SANDY LAKE RD
REVIEWER: JAHNS, DEBORAH K
9.4 OTHER SLEEPING ROOMS AND SUITES
PROJECT NO.: EABPRJA1008798
REVIEW EAB2001048169R
PAGE: 6
DATE: 07/02/01
9.5 SHELTERS, HALFWAY HOUSES, GROUP HOMES, OTHER ESTABLISHMENTS.
NOT NOTED 10 TRANSPORTATION FACILITIES
**NOTE: If bus stops are provided, compliance with section 10
is required.
10.1 GENERAL
10.2 BUS STOPS AND TERMINALS
10.3 FIXED FACILITIES AND STATIONS
10.4 AIRPORTS
10.5 BOAT AND FERRY DOCKS (Reserved)