Loading...
ST9302-CS010709 TEXAS DEPARTIVIEN'1' OF LICF,NSING AND REGULATION Code Review and Inspections ARCHITECTURAL BARRIERS P.O. Box 12157 Austin, Texas 78711 (512163-3211 (877)278-0999 FAX (512~t75-2886 Email Address: techinfo.aha(7.license.state.tx.us IntemetAddress: www.license.state.tx.us ~ `° t"`" e `~~ ~~c t p{~~rn. ~ , . ~~",, `' JEFF JAMES ~"'"a;?~~+ JUL-03-2001 KIMLEY HORN & ASSOC INC /~< 9 JEFF JAMES FORTCWORTH,STXU7610211 k/M~FY.y ~~~ Re: COPPELL SANDY LAKE RD EABPRJA1008798 PAVING/DRIANAGE WATER SYSTEM-COPPELL SANDY LAKE RD COPPELL, TX 75019 PLANS, SIGNED AND SEALED 06/29/98; AND SPECIFICATIONS Dear MR. JAMES Enclosed are the results of the plan review completed on the referenced project. Identified on the worksheet(s) are areas of nonconformance with accessibility standards adopted by the Texas Department of Licensing and Regulation for purposes of ensuring compliance with Article 9102, Texas Civil Statutes. Although nonconforming items have been noted, the referenced project will be eligible for approval if constructed according to the documents reviewed and as noted on the worksheet(s). Items which are the responsibility of the owner should be referred to the appropriate person for actipn. This determination does not address applicability of the Americans with Disabilities Act (ADA), (P. L. 101-336), or any other state, local, or federal requirement. For information on the ADA, call the ADA Hotline, (800)949-4232 or the United States Department of Justice at (202)514-0301. An inspection will be conducted within one year of the completion date. The building owner will be contacted to arrange the inspection. Please reference the EABPRJ number in all future correspondence pertaining to this project. :DKJ U~ Austi Headquarters: ~ ..~1 ~,~ V ~ ."iN" ~y~ State Utuce ttuuamg - ylu troioraao - Ausnn, -texas TEXAS DEPARTMENT OF LICENSING AND REGULATION PLANS AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT: PAVING/DRAANAGE WATER SYSTEM-COPPELL FACILITY: COPPELL SANDY LAKE RD OWNER: CITY OF COPPELL ARCHITECT: KIMLEY HORN & ASSOC INC REVIEWER: JAHNS, DEBORAH K PROJECT NO.: EABPRJA1008798 REVIEW EAB2001048169R PAGE: 1 DATE: 07/02/01 4 ACCESSIBLE ELEMENTS AND SPACES: TECHNICAL REQUIREMENTS **PROJECT DESCRIPTION: CONSTRUCTION OF REINFORCED CONCRETE PAVING, CONCRETE DRAINAGE CHANNEL, STORM DRAIN, AND WATER SYSTEM IMPROVEMENTS THE SCOPE OF WORK ALSO INCLUDES SIDEWALKS AND CURB RAMPS. **APPLICATION: 4.1.2 SITES AND EXTERIOR FACILITIES: NEW CONSTRUCTION ALL "COMPLIANCE REQUIRED" ITEMS MUST BE CORRECTED PRIOR TO INSPECTION TO BE APPROVED. ITEMS NOTED AS "UNACCEPTABLE", WHICH PS2E BEYOND THE SCOPE OF THE ENGINEER, SHOULD BE FORWARDED TO THE CITY OF COPPELL FOR ACTION. CONSTRUCTION DOCUMENTS CANNOT BE CONSIDERED APPROVED UNTIL ALL "UNACCEPTABLE" ITEMS ARE RESOLVED. UNACCEPTABLE 4.3 ACCESSIBLE ROUTE 4.3.7 Slope **NOTE: To comply with 4.3.7, the slope of new sidewalks cannot exceed 5$ in the direction of travel. According to plans, (ie. sheet 54), the slope exceeds 5~ in some areas. PLANS AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL FACILITY: COPPELL SANDY LAKE RD REVIEWER: JAHNS, DEBORAH K *COMPLIANCE REQUIRED WITH 4.3.7 NOT NOTED 4.4 PROTRUDING OBJECTS PROJECT NO.: EABPRJA1008798 REVIEW EAB2001048169R PAGE: 2 DATE: 07/02/01 **NOTE: Ensure that trees, overhead signage, utility boxes, fire hydrants, etc. do not protrude into the accessible route. 4.5 GROUND AND FLOOR SURFACES 4.5.1 General **NOTE: Unable to verify that the ground surface of the accessible route that crosses existing streets is in compliance with the requirements of 4.5. *COMPLZANCE REQUIRED WITH 4.5 NOT NOTED 4.6 PARKING AND PASSENGER LOADING ZONES UNACCEPTABLE 4.7 CURB RAMPS 4.7.2 Slope **NOTE: Insufficient information provided to verify that the slope of the adjoining gutters and road surface directly adjacent to new curb ramps is no more than 2~. *COMPLIANCE REQUIRED WITH 4.7.2 4.7.4 Surface **NOTE: Insufficient information provided on the standard detail sheet to verify that new curb ramps will have a texture that does not accummulate water and is detectable under foot, and a color that significantly contrasts with the adjoining sidewalk and street. *COMPLIANCE REQUIRED WITH 4.7.4 4.7.10 Diagonal Curb Ramps **NOTE: To comply with 4.7.10, diagonal Curb ramps with flared sides must have at least a 24" long segment of straight curb on each side of the curb ramp. According to the typical detail sheet, the straight segment of curb is not provided on diagonal curb ramps. FLANS~AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL FACILITY: COPPELL SANDY LAKE RD REVIEWER: JAHNS, DEBORAH K PROJECT NO.: EABPRJA1008798 REVIEW EAB2001046169R PAGE: 3 DATE: 07/02/01 *COMPLIANCE REQUIRED WITH 4.7.10 **NOTE: To comply with 4.7.10, the straight segment of curb ramp required for diagonal curb ramps must be located within the marked crossings. According to plans, curb ramps at marked crossings do not comply with this requirement. *COMPLIANCE REQUIRED WITH 4.7.10 NOT NOTED 4. 8 RAMPS NOT NOTED 4. 9 STAIRS NOT NOTED 4. 10 ELEVATORS NOT NOTED 4. 11 PLATFORM LIFTS (Wheelchair Lifts) NOT NOTED 4. 12 WINDOWS NOT NOTED 4. 13 DOORS NOT NOTED 4. 14 ENTRANCES NOT NOTED 4. 15 DRINKING FOUNTAINS AND WATER COOLERS NOT NOTED 4. 16 WATER CLOSETS NOT NOTED 4. 17 TOILET STALLS NOT NOTED 4. 16 URINALS NOT NOTED 4. 19 LAVATORIES AND MIRRORS NOT NOTED 4. 20 BATHTUBS NOT NOTED 4 .21 SHOWER STALLS NOT NOTED 4. 22 TOILET ROOMS NOT NOTED 4. 23 BATHROOMS, BATHING FACILITIES, AND SHOWER ROOMS NOT NOTED 4. 24 SINKS NOT NOTED 4. 25 STORAGE NOT NOTED 4. 26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS UNACCEPTABLE 4. 27 CONTROLS AND OPERATING MECHANISMS PLANS AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL FACILITY: COPPELL SANDY LAKE RD REVIEWER: JAHNS, DEBORAH K PROJECT NO.: EABPRJA1008798 REVIEW EAB2001048169R PAGE: 4 DATE: 07/02/01 4.27.2 Clear Floor Space **NOTE: To comply with 4.27.3, at least 30" x 48" of clear and level floor space must be centered on the pedestrian crosswalk controls. Insufficient information is provided to verify compliance. *COMPLIANCE REQUIRED WITH 4.27.2 4.27.3 Height **NOTE: To comply with 4.27.3, pedestrian cro sswalk controls must be mounted no higher than 54" AFF. Insufficient information is provided to verify compliance *COMPLIANCE REQUIRED WITH 4.27.3 NOT NOTED 4. 28 ALARMS NOT NOTED 4. 29 DETECTABLE WARNINGS NOT NOTED 4. 30 SIGNAGE NOT NOTED 4. 31 TELEPHONES NOT NOTED 4. 32 FIXED OR BUILT-IN SEATING AND TABLES NOT NOTED 4. 33 ASSEMBLY AREAS NOT NOTED 4. 34 AUTOMATED TELLER MACHINES NOT NOTED 4. 35 DRESSING AND FITTING ROOMS NOT NOTED 5 RESTAURANTS, CAFETERIAS, SNACK BARS, AND VENDING AREAS 5 .1 GENERAL 5 .2 COUNTERS AND BARS 5 .3 ACCESS AISLES 5 .4 DINING AREAS 5 .5 FOOD SERVICE LINES 5 .6 TABLEWARE AND CONDIMENT AREAS P,LANS.AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL FACILITY: COPPELL SANDY LAKE RD REVIEWER: JAHNS, DEBORAH K PROJECT NO.: EABPRJA1008798 REVIEW EAB2001046169R PAGE: 5 DATE: 07/02/01 5.7 RAISED PLATFORMS 5.8 VENDING MACHINES AND OTHER EQUIPMENT 5.9 QUIET AREAS (Reserved) NOT NOTED 6 MEDICAL CARE FACILITIES 6.1 GENERAL 6.2 ENTRANCES 6.3 PATIENT BEDROOMS 6.4 PATIENT TOILET ROOMS 6.5 SIZE OF AREAS OF RESCUE ASSISTANCE 6.6 INFORMATION COUNTERS AND NURSES STATIONS NOT NOTED 7 BUSINESS AND MERCANTILE 7.1 GENERAL 7.2 SALES AND SERVICE COUNTERS, TELLER WINDOWS, INFORMATION COUNTERS 7.3 CHECK-OUT AISLES 7.4 SECURITY BOLLARDS AND TURNSTILES NOT NOTED 8 LIBRARIES 6.1 GENERAL 8.2 READING AND STUDY AREAS 8.3 CHECK-OUT AREAS 8.4 CARD CATALOGS AND MAGAZINE DISPLAYS 8.5 STACKS NOT NOTED 9 ACCESSIBLE TRANSIENT LODGING 9.1 HOTELS, MOTELS, INNS, BOARDING HOUSES, DORMITORIES, RESORTS, ETC 9.2 REQUIREMENTS FOR ACCESSIBLE UNITS, SLEEPING ROOMS AND SUITES 9.3 VISUAL ALARMS. NOTIFICATION DEVICES AND TELEPHONES .PL,ANS•AND SPECIFICATIONS REVIEW WORKSHEET Article 9102, T.C.S. PROJECT: PAVING/DRIANAGE WATER SYSTEM-COPPELL FACILITY: COPPELL SANDY LAKE RD REVIEWER: JAHNS, DEBORAH K 9.4 OTHER SLEEPING ROOMS AND SUITES PROJECT NO.: EABPRJA1008798 REVIEW EAB2001048169R PAGE: 6 DATE: 07/02/01 9.5 SHELTERS, HALFWAY HOUSES, GROUP HOMES, OTHER ESTABLISHMENTS. NOT NOTED 10 TRANSPORTATION FACILITIES **NOTE: If bus stops are provided, compliance with section 10 is required. 10.1 GENERAL 10.2 BUS STOPS AND TERMINALS 10.3 FIXED FACILITIES AND STATIONS 10.4 AIRPORTS 10.5 BOAT AND FERRY DOCKS (Reserved)