Freeport NIP(7.0)-LR031007RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site 4000 psi 28 Days 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 5.25 5.25 5.25 5.25 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS SAMPLE LOCATION: Northwest entrance, 50' south, 10' west Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 10/06/2003 10/27/2003 10/27/2003 11/24/2003 AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 121885 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 195426 037333 09/29/2003 10/07/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/29/2003 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 5:2Oam BATCH TIME: 5:O l am TEMPERATURE (F) AIR 57 F CONCRETE: 74 F TRUCK NO: 108 TICKET NO: 500 AIR CONTENT 4.6 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest entrance, 210' east, 180' south and 270' west COMPRESSIVE STRENGTH (Psi) FRACTURE TYPE 4310 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 3 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 2 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. SPECIFICATION REQUIREMENTS Duke Realty Services, LP Potter On site 4000 psi 28 Days 3 -5" 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) Concrete Compressive Cylinder 6" x 12" (area 28.27 sq DATE TESTED 5.5 10/06/2003 5.5 10/27/2003 5.5 10/27/2003 5.5 11/24/2003 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS MIX DESIGN LD.: 7752 PLACEMENT DATE: 09/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED 7 BATCH TIME: 6:44am TEMPERATURE (F) AIR 59 F CONCRETE: 82 F TRUCK NO: 101 TICKET NO: 510 AIR CONTENT 5.5 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest entrance, 210' east, 180' south and 270' west SAMPLE LOCATION: Northwest entrance, 60' east, 15' south AGE (days) 7 28 28 56 in.) MAXIMUM LOAD (lbs. force) 117775 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 195426 037333 09/29/2003 10/07/2003 FRACTURE TYPE 4160 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 3 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 3" 5" AIR 3% 6% TEST METHOD: CYLINDER MARKED SET NO. 3 1 3 2 3 3 3 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 5.5 5.5 5.5 5.5 Technician: Shawn Deal Report Distribution: (I) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (I) Potter Concrete Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 10/06/2003 10/27/2003 10/27/2003 11/24/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Started: 4:30am MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/29/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 9:30am BATCH TIME: 8:58am TEMPERATURE (F) MR 70 F CONCRETE: 78 F TRUCK NO: 101 TICKET NO: 520 AIR CONTENT 5.4 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest entrance, 210' east, 180' south and 270' west SAMPLE LOCATION: Northwest entrance, 50' south, 150' east AGE (days) 7 28 28 56 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Finished: 10:30am MAXIMUM LOAD (Ibs. force) 105520 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 195426 037333 09/29/2003 10/07/2003 FRACTURE TYPE 3730 Unbonded Cap Unbonded Cap Unbonded Cap ‚33 Unbonded Cap fAirr atilites K. Scott Watson, 1 T CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 3 of 3