Freeport NIP(7.0)-LR031002RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER. Potter PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. On site 4000 psi 28 Days 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MEASURED SLUMP DATE (inches) TESTED 5.5 10/01/2003 5.5 10/22/2003 5.5 10/22/2003 5.5 11/19/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 195099 037333 09/24/2003 10/02/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/24/2003 WEATHER CONDITIONS: Cloudy, dark TIME SAMPLED: 5: loam BATCH TIME: 4:51am TEMPERATURE (F) AIR 73 F CONCRETE: 86 F TRUCK NO: 104 TICKET NO: 397 AIR CONTENT 4.9 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest corner of building, 200' north, 180' south, 280' west SAMPLE LOCATION: Northwest corner of building, 220' west, 130' south AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 107798 COMPRESSIVE STRENGTH (Psi) 3810 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS 2 1 5.5 2 2 5.5 2 3 5.5 2 4 5.5 4000 psi 28 Days 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 10/01/2003 10/22/2003 10/22/2003 11/19/2003 PROJECT DATA REPORT OF TESTS SAMPLE LOCATION: Northwest corner of building, 45' south, 180' west AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 112760 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/24/2003 WEATHER CONDITIONS: Cloudy, dark TIME SAMPLED: 6:30am BATCH TIME: 6:08am TEMPERATURE (F) AIR 75 F CONCRETE: 85 F TRUCK NO: 110 TICKET NO: 408 AIR CONTENT 4.4 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest comer of building, 200' north, 180' south, 280' west COMPRESSIVE STRENGTH (Psi) 195099 037333 09/24/2003 10/02/2003 FRACTURE TYPE 3990 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality .(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS 4000 psi 28 Days 3" 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 3 1 5.25 10/01/2003 3 2 5.25 10/22/2003 3 3 5.25 10/22/2003 3 4 5.25 11/19/2003 Water added at site: 10 gallons 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 104645 Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/24/2003 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 7.45am BATCH TIME: 7:21am TEMPERATURE (F) AIR 76 F CONCRETE: 85 F TRUCK NO: 102 TICKET NO: 417 AIR CONTENT 5.3 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest comer of building, 200' north, 180' south, 280' west SAMPLE LOCATION: Northwest corner of building, 60' north, 120' west COMPRESSIVE STRENGTH (Psi) 195099 037333 09/24/2003 10/02/2003 FRACTURE TYPE 3700 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 3 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -I43 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. MEASURED SLUMP DATE (inches) TESTED 4 1 6.0 10/01/2003 4 2 6.0 10/22/2003 4 3 6.0 10/22/2003 4 4 6.0 11/19/2003 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/24/2003 WEATHER CONDITIONS: Cloudy TIME SAMPLED 8-55am BATCH TIME: 8:37am TEMPERATURE (F) AIR 80 F CONCRETE: 86 F TRUCK NO: 1 TICKET NO: 428 AIR CONTENT 5.5 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest comer of building, 200' north, 180' south, 280' west SAMPLE LOCATION: Northwest comer of building, 60' north, 85' west Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 77320 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 195099 037333 09/24/2003 10/02/2003 FRACTURE TYPE 2730 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 4 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. SPECIFICATION REQUIREMENTS MEASURED SLUMP (inches) 5 1 4.0 10/01/2003 5 2 4.0 5 3 4.0 5 4 4.0 Technician: Shawn Deal Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete Duke Realty Services, LP Potter On site 4000 psi 28 Days 3" 5" 3 %a -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 10/22/2003 10/22/2003 11/19/2003 PROJECT DATA REPORT OF TESTS Started: 4:30am AGE (days) 7 28 28 56 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections SAMPLE LOCATION: Northwest corner of building, 100' north, 110' west curb Finished: 11:15am MAXIMUM LOAD (Ibs. force) 119515 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/24/2003 WEATHER CONDITIONS: Cloudy TIME SAMPLED 10:20am BATCH TIME 9 TEMPERATURE (F) AIR 83 F CONCRETE• 87 F TRUCK NO: 112 TICKET NO: 438 AIR CONTENT 4.6 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Northwest parking from northwest comer of building, 200' north, 180' south, 280' west COMPRESSIVE STRENGTH (Psi) 195099 037333 09/24/2003 10/02/2003 FRACTURE TYPE 4230 Unbonded Cap K. Scott Watson, AET CMT Operations Manager Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 5 of 5