Freeport NIP(7.0)-LR030930RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. 1 1 Duke Realty Services, LP Potter On site MEASURED SLUMP DATE (inches) TESTED 1 1 4.0 09/29/2003 2 4.0 10/20/2003 3 4.0 10/20/2003 1 4 4.0 11/17/2003 Water added at site: 10 gallons 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) Report No.: Project No.: Date of Service: Report Date: 194925 037333 09/22/2003 09/30/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 5:20am BATCH TIME: 4:45am TEMPERATURE (F) AIR 70 F CONCRETE: 80 F TRUCK NO: 1 TICKET NO: 348 AIR CONTENT 4.5 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Parking lot, southwest corner of building SAMPLE LOCATION: 10' north, 10' west of southwest corner of building AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 123575 COMPRESSIVE STRENGTH (Psi) FRACTURE TYPE 4370 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 1 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5„ maximum AIR Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 2 1 4.5 09/29/2003 2 2 4.5 2 3 4.5 2 4 4.5 Duke Realty Services, LP 3% 6% AIR CONTENT 4.0 UNIT WEIGHT (pcf): NA Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 10/20/2003 10/20/2003 11/17/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 6:00am BATCH TIME: 5:41 am TEMPERATURE (F) AIR 70 F CONCRETE: 81 F TRUCK NO: 1 TICKET NO: 356 OVERALL PLACEMENT LOCATION: Parking lot, southwest comer of building SAMPLE LOCATION: 50' west, 30' north of southwest corner of building AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 125510 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 COMPRESSIVE STRENGTH (Psi) 194925 037333 09/22/2003 09/30/2003 FRACTURE TYPE 4440 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 3 1 3 2 3 3 3 4 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 5.0 09/29/2003 5.0 10/20/2003 5.0 10/20/2003 5.0 11/17/2003 PROJECT DATA REPORT OF TESTS OVERALL PLACEMENT LOCATION: Parking lot, southwest comer of building SAMPLE LOCATION: 100' north, 50' west of southwest corner of building AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 107085 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: 194925 037333 09/22/2003 09/30/2003 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:OOam BATCH TIME: 6:4Oam TEMPERATURE (F) AIR 68 F CONCRETE: 82 F TRUCK NO: 101 TICKET NO: 366 AIR CONTENT 4.7 UNIT WEIGHT (pct): NA COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3790 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. O1DD Page 3 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: CONCRETE SUPPLIER: PLANT: CYLINDER MARKED SET NO. 4 1 4 3 4 4 Duke Realty Services, LP Potter On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 4.5 09/29/2003 4 2 4.5 10/20/2003 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 4.5 10/20/2003 4.5 11/17/2003 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:50am BATCH TIME: 7:32am TEMPERATURE (F) AIR 70 F CONCRETE: 80 F TRUCK NO: 115 TICKET NO: 376 AIR CONTENT 5.1 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Parking lot, southwest corner of building SAMPLE LOCATION: 125' west, 10' north of southwest corner of building AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 108145 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 194925 037333 09/22/2003 09/30/2003 FRACTURE TYPE 3820 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 4 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR TEST METHOD: CYLINDER MARKED SET NO. 5 1 5.0 5 2 5.0 5 3 5.0 5 4 5.0 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) Concrete Compressive Cylinder 6" x 12" (area 28 27 sq in DATE TESTED 09/29/2003 10/20/2003 10/20/2003 11/17/2003 CONCRETE COMPRESSIVE STRENGTH TEST REPORT OF TESTS Started: 5:30am PROJECT DATA AGE (days) 7 28 28 56 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections SAMPLE LOCATION: 150' west, 75' north of southwest corner of building Finished: 10:30am MAXIMUM LOAD (lbs. force) 103300 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 194925 037333 09/22/2003 09/30/2003 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 9:OSam BATCH TIME: 8:24am TEMPERATURE (F) AIR 72 F CONCRETE: 82 F TRUCK NO: 101 TICKET NO: 386 AIR CONTENT 4.7 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Parking lot, southwest comer of building 3650 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap K. cott Watson, AET CMT Operations Manager FRACTURE TYPE LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 5 of 5