Loading...
Freeport NIP(7.0)-LR030929RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 1 2 3 Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -23I ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 4.00 08/08/2003 4.00 08/29/2003 4.00 08/29/2003 1 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS SAMPLE LOCATION: 10' south, 10' west of northeast corner Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 114520 113235 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 91830 3250 4050 4000 4030 192011 037333 08/01/2003 09/29/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:20am BATCH TIME: 7:O6am TEMPERATURE (F) AIR 80 F CONCRETE: 86 F TRUCK NO: 108 TICKET NO: 117778 AIR CONTENT 3.6 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to GG FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01 Pagel of RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 4000 psi 28 Days 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 4.50 4.50 4.50 DATE TESTED 08/08/2003 08/29/2003 08/29/2003 2 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 8:20am BATCH TIME: 8:03am TEMPERATURE (F) AIR 81 F CONCRETE: 86 F TRUCK NO: 113 TICKET NO: 117786 AIR CONTENT 4.0 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to OG SAMPLE LOCATION: 40' west, 15' north of southeast corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 92250 118540 114570 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 COMPRESSIVE STRENGTH (psi) 3260 4190 4050 4120 192011 037333 08/01/2003 09/29/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01 Page 2 of 7 RoneEngineers .A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 3 1 4.50 Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 08/08/2003 3 2 4.50 08/29/2003 3 3 4.50 08/29/2003 3 4 4.50 09/26/2003 56 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 93200 114305 109060 Average Does not comply with specified strength. Report No.: Project No.: Date of Service: Report Date: Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED 9 BATCH TIME: 9:12am TEMPERATURE (F) AIR 85 F CONCRETE: 87 F TRUCK NO: 1 TICKET NO: 117796 AIR CONTENT 3.9 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to GG SAMPLE LOCATION: 75' west, 15' north of southeast corner COMPRESSIVE STRENGTH (psi) 3300 4040 3860 3950 124135 4390 192011 037333 08/01/2003 09/29/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01 Page 3 of 7 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MEASURED SLUMP (inches) 4 1 5.00 Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 DATE TESTED 08/08/2003 4 2 5.00 08/29/2003 4 3 5.00 08/29/2003 4 4 Hold Water added at site: 5 gallons AGE (days) 7 28 28 SAMPLE LOCATION: 125' west, 10' south of northeast comer REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MAXIMUM LOAD (lbs. force) 94120 115365 117855 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: PROJECT DATA MIX DESIGN LD.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:20am BATCH TIME: 10:07arn TEMPERATURE (F) AIR 86 F CONCRETE: 88 F TRUCK NO: 113 TICKET NO: 117806 AIR CONTENT 4.5 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to GG COMPRESSIVE STRENGTH (psi) 3330 4080 4170 4130 192011 037333 08/01/2003 09/29/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01 Page 4 of 7 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 5 1 5 2 5 3 5 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 5.00 08/08/2003 5.00 08/29/2003 5.00 08/29/2003 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF' TESTS Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 11:20am BATCH TIME: 11:OOam TEMPERATURE (F) AIR 88 F CONCRETE: 90 F TRUCK NO: 1 12 TICKET NO: 1 17817 AIR CONTENT 4.2 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to OG SAMPLE LOCATION: 100' east, 10' south of northwest corner AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 90450 118400 113355 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 COMPRESSIVE STRENGTH (psi) 3200 4190 4010 4100 192011 037333 08/01/2003 09/29/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 11 Page of RoneEngineers .A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 6 1 5.00 DATE TESTED 08/08/2003 6 2 5.00 08/29/2003 6 3 5.00 08/29/2003 6 4 Hold Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS MIX DESIGN 1.D.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 12:l Opm BATCH TIME: 11:55arn TEMPERATURE (F) AIR 92 F CONCRETE: 90 F TRUCK NO: 108 TICKET NO: 117826 AIR CONTENT 4.7 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to GG SAMPLE LOCATION: 75' east, 10' north of southwest corner Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 89815 113850 113695 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 3180 4030 4020 4030 192011 037333 08/01/2003 09/29/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 1t Page 6 of 7 RoneEngineers A LEIGH COMPANY Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MEASURED MARKED SLUMP SET NO. (inches) 7 1 5.00 7 2 5.00 7 3 5.00 7 4 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete 4000 psi 28 Days 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 DATE TESTED 08/08/2003 08/29/2003 08/29/2003 Hold 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) Started: 6:30am AGE (days) 7 28 28 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Finished: 2:30pm MAXIMUM LOAD (Ibs. force) 88210 113275 113480 Average Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/01/2003 WEATHER CONDITIONS: Clear TIME SAMPLED P1 Opm BATCH TIME: 12:46pm TEMPERATURE (F) AIR 94 F CONCRETE: 92 F TRUCK NO: 103 TICKET NO: 117836 AIR CONTENT 4.3 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of north parking lot, building column line Z to GG SAMPLE LOCATION: 25' east, 10' north of southwest comer COMPRESSIVE STRENGTH (psi) 3120 4010 4010 4010 192011 037333 08/01/2003 09/29/2003 K. Scott Watson, AET CMT Operations Manager FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 71 Page 7 of 7