Freeport NIP(7.0)-LR030925RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUI
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
1 1
2
3
1 4
CONCRETE COMPRESSIVE STRENGTH TEST
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
Duke Realty Services, LP
Potter
On site
REMENTS
4000 psi 28 Days
5" maximum
3% 6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
MEASURED
SLUMP DATE
(inches) TESTED
5.00 08/06/2003
5.00 08/27/2003
5.00 08/27/2003
5.00
09/24/2003 56
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 07/30/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED: 7:OSam BATCH TIME: 6:49am
TEMPERATURE (F) AIR 83 F CONCRETE: 88 F
TRUCK NO: 105 TICKET NO: 117703
AIR CONTENT 4.3 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot at northeast entrance.
SAMPLE LOCATION: 10' west, 10' north of southeast
corner
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
77500
102425
100365
Average
Does not comply with specified strength.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214)630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(psi)
2740
3620
3550
3590
120355 4260
191630
037333
07/30/2003
09/25/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 1 of 6
RoneEngineers
A LEIG H COMPANY
Client: Duke Realty Services, LP
Attn. Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
2 1
4000 psi 28 Days
5" maximum
3% 6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP
(inches)
5.00 08/06/2003
DATE
TESTED
2 2 5.00 08/27/2003
2 3 5.00 08/27/2003
2 4 5.00 09/24/2003
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Report No.:
Project No::
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 07/30/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED: 8:1 Oam BATCH TIME: 7:5Oam
TEMPERATURE (F) AIR 85 F CONCRETE: 88 F
TRUCK NO: 105 TICKET NO: 117715
AIR CONTENT 3.4 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
North half of north parking lot at northeast entrance
SAMPLE LOCATION: 10' east, 5' north of southwest
corner
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
MAXIMUM
LOAD
(lbs. force)
84950
104715
108245
Average
Does not comply with specified strength.
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
COMPRESSIVE
STRENGTH
(psi)
3000
3700
3830
3770
56 121270 4290
191630
037333
07/30/2003
09/25/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rene Engineers, Ltd.
01 Page 2 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Lan •ston
5495 Belt o.. Suite 360
Dalla
Project:
Services:
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
3 1
3% 6%
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
5.00 08/06/2003
3 2 5.00 08/27/2003
3 3 5.00 08/27/2003
3 4 5.00 09/24/2003
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
Report No.:
Project No.:
Date of Service:
Report Date:
191630
037333
07/30/2003
09/25/2003
1, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 07/30/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED: 8:55am BATCH TIME: 8:43am
TEMPERATURE (F) AIR 85 F CONCRETE: 89 F
TRUCK NO: 110 TICKET NO: 117725
AIR CONTENT 4.3 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
South half of north parking lot, building column lines R to U
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
SAMPLE LOCATION: 15' north, 10' west of southeast
comer
AGE
(days)
7
MAXIMUM
LOAD
(Ibs. force)
88575
114445
110160
Average
56 123200
Does not comply with specified strength.
COMPRESSIVE
STRENGTH
(psi)
Nct
FRACTURE
TYPE
3130 Unbonded Cap
Unbonded Cap
Unbonded Cap
4360 Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 3 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn• Mr Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT: On site
SPECIFICATION REQUIREMENTS
STRENGTH: 4000 psi 28 Days
SLUMP (in): 5" maximum
AIR 3% 6%
TEST METHOD: ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
CYLINDER
MARKED
SET NO.
4 1
MEASURED
SLUMP DATE
(inches) TESTED
4 2 5.00 08/27/2003
4 3 5.00 08/27/2003
4 4 5.00 09/24/2003
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
SAMPLE LOCATION: 10' east, 10' north of southwest
corner
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
5.00 08/06/2003
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 07/30/2003
WEATHER CONDITIONS: Partly cloudly
TIME SAMPLED: 9:50am BATCH TIME: 9:32am
TEMPERATURE (F) AIR 87 F CONCRETE: 89 F
TRUCK NO: 1 15 TICKET NO: 117725
AIR CONTENT 4.6 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
South half of north parking lot, building column lines R to U
AGE
(days)
7
28
28
56
MAXIMUM
LOAD
(lbs. force)
90905
109280
114520
Average
Does not comply with specified strength.
Water added at site: 10 gallons
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
COMPRESSIVE
STRENGTH
(psi)
3210
3860
4050
3960
125805 4450
191630
037333
07/30/2003
09/25/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 4 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project:
Services:
CONTRACTOR:
CONCRETE SUPPLIER:
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
5 1
5 2
5 3
5 4
Duke Realty Services, LP
Potter
On site
4000 psi 28 Days
5" maximum
3% 6%
ASTM C -172
ASTM C -31
ASTM C -I43
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
MEASURED
SLUMP DATE
(inches) TESTED
4.50 08/06/2003
4.50 08/27/2003
4.50 08/27/2003
4.50 09/24/2003
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
AGE
(days)
7
28
28
MAXIMUM
LOAD
(Ibs. force)
109570
109950
Average
Does not comply with specified strength.
Report No.:
Project No.:
Date of Service:
Report Date:
Freeport 10
500 Freeport Parkway
Coppell, TX
Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
MIX DESIGN LD.: 7752
PLACEMENT DATE: 07/30/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED: 10:55am BATCH TIME: 10:37am
TEMPERATURE (F) AIR 86 F CONCRETE: 90 F
TRUCK NO: 103 TICKET NO: 1 17746
AIR CONTENT 3.5 UNIT WEIGHT (pct): NA
OVERALL PLACEMENT LOCATION:
North half of south parking lot, building column line E to J
SAMPLE LOCATION: 20' south, 20' west of northeast
comer
COMPRESSIVE
STRENGTH
(ps
86865 3070
3870
3890
3880
56 130070 4600
191630
037333
07/30/2003
09/25/2003
FRACTURE
TYPE
Unbonded Cap
Unbonded Cap
Unbonded Cap
Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 5 of 6
Rone Engineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, rform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in acto r.. ce with applicable standards.
CONTRACTOR: Duke Realty Services, LP
CONCRETE SUPPLIER: Potter
PLANT:
SPECIFICATION REQUIREMENTS
STRENGTH:
SLUMP (in):
AIR
TEST METHOD:
CYLINDER
MARKED
SET NO.
On site
MEASURED
SLUMP
(inches)
6 1 5.00
6 2 5.00
6 3 5.00
6 4 5.00
Technician: Lanny Gist
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Potter Concrete
4000 psi 28 Days
5" maximum
ASTM C -172
ASTM C -31
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138
ASTM C -39
DATE
TESTED
08/06/2003
08/27/2003
08/27/2003
09/24/2003
CONCRETE COMPRESSIVE STRENGTH TEST
PROJECT DATA
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
(1) Pacheco Koch Consulting Engineers
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
Report No.:
Project No.:
Date of Service:
Report Date:
MIX DESIGN I.D.: 7752
PLACEMENT DATE: 07/30/2003
WEATHER CONDITIONS: Partly cloudy
TIME SAMPLED- 11:40am BATCH TIME: 11:1 lam
TEMPERATURE (F) AIR 90 P CONCRETE: 91 F
TRUCK NO: 1 TICKET NO: 117754
3% 6% AIR CONTENT 5.1 UNIT WEIGHT (pcf): NA
OVERALL PLACEMENT LOCATION:
North half of south parking lot, building colu y.Mfie/to
AGE
(days)
7
28
28
MAXIMUM
LOAD
(ibs. force)
79505
104235
98245
Average
56 117995
Does not comply with specified strength.
Started: 7:OOam Finished: 2:30pm
I.
te._
SAMPLE LOCATION: 10' so€th, 10' west of northeast
corner
COMPRESSIVE
STRENGTH
(psi)
191630
037333
07/30/2003
09/25/2003
FRACTURE
TYPE
2810 Unbonded Cap
Unbonded Cap
Unbonded Cap
4170 Unbonded Cap
K. Scott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
01 Page 6 of 6
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Reinforcing Steel Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform Reinforcing Steel Inspection. The results are attached.
Technician Time: 4 :30 AM 5 :30 AM
Page 1 of 2
Technician: Lanny Gist
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Pacheco Koch Consulting Engineers
Report of Inspection
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
REPORT OF REINFORCING STEEL INSPECTION
Report No.:
Project No.:
Date of Service:
Report Date:
194926
037333
09/22/2003
09/25/2003
K. Scott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
"ports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
F
Items inspected:
Conforming
Non
Conforming
Items Inspected:
Conforming
Non
Conforming
Items Inspected:
Conforming
Non
Conforming
Placing Drawings
Approved
Bar Length
and Shape
Column Ties Properly
Tied and Spaced
Bar Size
L/
Proper Bar Placement
L--
Stirrup Spacing and Type
Bar Grade
Properly Tied
Lapped Splices
Bars Clean
[i
Dowel Bars in Place
L/
Welded Splices
Fonn Clean
V
Proper Bar Supports
f---
Mechanical Splices
Number Bars
Proper Cover
L�
Rone Engineers
Client: Do KC
Project: Freeftrd /o
Locations and Items Inspected:
Discrepancies Comments: cA4,r5 gelded d
A a tr e/5 Id ed -4 /°La tee o cifs,
Inspector's Signature: 2 6
6300 Rothway, Suite 150
Houston, Texas 77040
(713) 996-9979
8908 Ambassador Row
Dallas, Texas 75247
(214) 630 -9745
Report of
Reinforcing Steel Inspection
Report No.: l nd 6
Project No.: 03 7333
q
Date of Service: Z? —0 3
Page of Z
S. co rner of (off
2696 Gravel Drive
Fort Worth, Texas 76118
(817) 284 -1318
doncr-e{e'la eeuo e
Time: 5 oo,3n to 5 304
Client/Contractor Signature: Client/Contractor Copied with Results: Yes No
LIMITATIONS: The test results presented herein were prepared hurt upon the specific samples provided for testing. We uNSrvn r., ,spoodbility for vanaion in quality (composition
2014(7/03) appearance. performance. etc.) or any other feature of similar subject matter provided by persons or conditions over whmh we have nu cunlml. Our letters and reports are for the [Willi
use of the clients to whom they are addressed and shall not be reproduced except n full without the written approval of Rone Engineers, Ltd.
RoneEngineers
A LEIGH COMPANY
Client: Duke Realty Services, LP
Attn: Mr. Jeff Langston
5495 Belt Line Road, Suite 360
Dallas TX 75254
Project: Freeport 10
500 Freeport Parkway
Coppell, TX
Services: Reinforcing Steel Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform Reinforcing Steel Inspection. The results are attached.
Technician Time: 6:30am 7:45am
Page 1 of 2
Technician- Lanny Gist
Report Distribution:
(1) Duke Realty Services, LP
(1) Duke Realty Services, LP
(1) City of Coppell Engineering Dept.
(1) Pacheco Koch Consulting Engineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630 -9745
REPORT OF REINFORCING STEEL INSPECTION
Report of Inspection
(1) Engineering Analyst
(1) City of Coppell Bldg. Inspections
Report No.:
Project No.:
Date of Service:
Report Date:
194343
037333
09/09/2003
09/11/2003
K. Scott Watson, AET
CMT Operations Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be renroduced except in full without the written approval of Rone Engineers, Ltd.
99DD
Rorie Engineers
Client: 0 u kN
Project: Free fca(a-
Discrepancies Comments: l3a i
p lot fin PAt
Inspector's Signature: L `4
6300 Rothway, Suite 150
Houston, Texas 77040
(713) 996-9979
Report of
Reinforcing Steel Inspection
is1f
Report No.:
Project No.:
Date of Service:
Page
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
1
3 93 33
4 9 -0 3
2 of ?i
Locations and Items Inspected: )9Q2 ^9 /o f P'" y lea Pe oaf t r r-e
u -tv LL
Items Inspected:
Placing Drawings
A .roved
Conforming
Non
Conforming
Bar Size
Bar Grade
Bars Clean
Form Clean
Number Bars
t�
Items Inspected:
Bar Length
and Shape
Proper Bar Placement
Properly Tied
Dowel Bars in Place
Proper Bar Supports
Proper Cover
Conforming
Ei
Non
Conforming
Items Inspected:
Column Ties Properly
Tied and Spaced
Stirrup Spacing and Type
Lapped Splices
Welded Splices
Mechanical Splices
Conforming
Non
Conforming
LIMITATIONS: M lest results Im¢ni d herein were Prepared bn¢d upon the specific samples provided for resting. We aswm w. •..pnnsibilily for variation in quality (rompasiden
2014 (7/03) appeanknce.perfomrnnce.em.) or my other feature of similar subject matter provided by persons or conditions over which we have nu control. Orourlee and report are for the ...mews
UK of Me clients to whom they are addressed and shall not be reproduced eereln in full without Chi Will. approval of Rene Engioms, Ltd.
2696 Gravel Drive
Fort Worth, Texas 76118
(817) 284-1318
Time: 7:oo,1fr, to 1; 303n
Client/Contractor Signature: Client/Contractor Copied with Results: Yes No