Loading...
Freeport NIP(7.0)-LR031009Ro Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (I) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 5.0 10/08/2003 5.0 10/29/2003 5.0 10/29/2003 5.0 11/26/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA Started: 6:30am (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 196035 037333 10/01/2003 10/09/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/01/2003 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 7:40am BATCH TIME: 7:OOam TEMPERATURE (F) AIR 68 F CONCRETE: 80 F TRUCK NO: 1 18 TICKET NO: 549 AIR CONTENT 5.1 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North sidewalk SAMPLE LOCATION: 30' east of northwest driveway approach REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 28 56 Finished: 9:30am MAXIMUM LOAD (Ibs. force) 106220 COMPRESSIVE STRENG FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson, CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Pagel of