Loading...
Freeport NIP(7.0)-LR031008RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 2 1 3 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter Concrete On site 3% 5% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 4.25 09/16/2003 4.25 10/07/2003 4.25 10/07/2003 1 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/09/2003 WEATHER CONDITIONS: Clear TIME SAMPLED. 8 TEMPERATURE (F) AIR TRUCK NO: 103 AIR CONTENT 3.1 SAMPLE LOCATION: Column line JJ REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 97985 120385 126735 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: BATCH TIME: 7:33am 78 F CONCRETE: 91 F TICKET NO: 251 UNIT WEIGHT (pcf): OVERALL PLACEMENT LOCATION: North parking lot, paving leave out, column lines U thru LL COMPRESSIVE STRENGTH (Psi) 3470 4260 4480 4370 194344 037333 09/09/2003 10/08/2003 NA FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 2 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 2 4 Duke Realty Services, LP Potter Concrete On site 4000 psi 28 Days 3 -5" ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 5.0 5.0 5.0 Water added at site: 5 gallons Technician: Ryan Armstrong Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (I) City of Coppell Engineering Dept. (1) Potter Concrete DATE TESTED 09/16/2003 10/07/2003 10/07/2003 Hold 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA Report No.: Project No.: Date of Service: Report Date: 194344 037333 09/09/2003 10/08/2003 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/09/2003 WEATHER CONDITIONS: Clear TIME SAMPLED. 9 BATCH TIME: 9:03am TEMPERATURE (F) AIR 81 F CONCRETE: 95 F TRUCK NO: 103 TICKET NO: 259 3% 5% AIR CONTENT %n): 2.9 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: North parking lot, paving leave out, column lines U thru LL SAMPLE LOCATION: Column line EE REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) Started: 7:OOam AGE (days) 7 28 28 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections Finished: 11:15am MAXIMUM LOAD (lbs. force) 101565 124190 126500 Average COMPRESSIVE STRENGTH (psi) 3590 4390 4470 4430 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 2