Freeport NIP(7.0)-LR031015Rorie Engineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. MEASURED SLUMP (inches) 1 1 6.0 1 2 1 3 4000 psi 28 Days 3 -5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 DATE TESTED 10/14/2003 6.0 11/04/2003 6.0 11/04/2003 1 4 6.0 12/02/2003 56 Water added at site: 10 gallons 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: 196405 037333 10/07/2003 10/15/2003 PROJECT DATA MIX DESIGN LD.: 7752 PLACEMENT DATE: 10/07/2003 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 5:1 Sam BATCH TIME: 4:5Oam TEMPERATURE (F) AIR 68 F CONCRETE: 76 F TRUCK NO: 101 TICKET NO: 617 AIR CONTENT 4.4 UNIT WEIGHT (pcfj: NA OVERALL PLACEMENT LOCATION: North side parking starting at northwest comer of building. 150' east, 100' north, east 80' then north 30' then east 120' then north 60' then west 200' SAMPLE LOCATION: 180' east, 110' north of northwest corner of building REPORT OF TESTS Concrete Compressive Cylinder 6" x l2" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 108485 COMPRESSIVE STRENGTH (Psi) FRACTURE TYPE 3840 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 3 RoneEngineers ire Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. Duke Realty Services, LP Potter On site 4000 psi 28 Days 3" 5" 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 2 1 6.0 10/14/2003 2 2 6.0 11/04/2003 2 3 6.0 11/04/2003 2 4 6.0 12/02/2003 Water added at site: 10 gallons SAMPLE LOCATION: 230' east, 165' north of northwest comer of building REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 113450 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/07/2003 WEATHER coNDmONS: Cloudy TIME SAMPLED: 6:SOam BATCH TIME: 6:37am TEMPERATURE (F) AIR 70 F CONCRETE' 83 F TRUCK NO: 105 TICKET NO: 627 AIR CONTENT 5.2 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: North side parking starting at northwest comer of building, 150' east, 100' north, east 80' then north 30' then east 120' then north 60' then west 200' COMPRESSIVE STRENGTH (psi) 196405 037333 10/07/2003 10/15/2003 FRACTURE TYPE 4010 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 2 of 3 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 3" 5" AIR 3% 6% TEST METHOD: CYLINDER MARKED SET NO. 3 1 3 2 3 3 3 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 6.0 10/14/2003 6.0 6.0 6.0 Standby: slow pour Technician: Shawn Deal Report Distribution: (1) Duke Realty Services, LP (I) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 11/04/2003 11/04/2003 12/02/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN LD.: 7752 PLACEMENT DATE: 10/07/2003 WEATHER CONDITIONS: Partly cloudy TIME SAMPLED: 9:OOam BATCH TIME: 8:28arn TEMPERATURE (F) AIR 73 F CONCRETE: 81 F TRUCK NO: 108 TICKET NO: 637 MR CONTENT 5.5 UNIT WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: North side parking starting at northwest corner of building, 150' east, 100' north, east 80' then north 30' then east 120' then north 60' then west 200' Started: 4:30am AGE (days) 7 28 28 56 (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections SAMPLE LOCATION: 170' east, 180' north of northwest corner of building MAXIMUM LOAD (Ibs. force) 114795 Finished: 10:00arn 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rotbway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 196405 037333 10/07/2003 10/15/2003 FRACTURE TYPE 4060 Unbonded Cap K. Scott Watson, AET CMT Operations Manager Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 3 of 3