Loading...
Freeport NIP(7.0)-LR031017RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: CYLINDER MARKED SET NO. 1 1 1 2 1 3 1 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 5.0 5.0 5.0 5.0 Concrete Compressive Cylinder 6" x 12" (area 28 27 sq in DATE TESTED 08/28/2003 09/18/2003 09/18/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/21/2003 WEATHER CONDFFIONS: Clear TIME SAMPLED: 7:3 5 am BATCH TIME: 7:158M TEMPERATURE (F) AIR 81 F CONCRETE 86 F TRUCK NO: 107 TICKET NO: 11 AIR CONTENT 4.7 UNIT WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: South half of east fire lane and parking area, southeast comer of building REPORT OF TESTS AGE (days) 7 28 28 10/16/2003 56 SAMPLE LOCATION: Southeast parking area, 20' east, 20' south of northwest corner Does not comply with specified strength. MAXIMUM LOAD (Ibs. force) 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 192917 037333 08/21/2003 10/17/2003 74650 96350 99525 Average 109555 3870 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 1 of 5 Ro gin to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 2 1 4.5 Duke Realty Services, LP Potter On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 08/28/2003 2 2 4.5 09/18/2003 2 3 4.5 09/18/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MIX DESIGN LD.: 7752 PLACEMENT DATE: 08/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 9:OOam BATCH TIME: 8:34am TEMPERATURE (F) AIR 82 F CONCRETE: 88 F TRUCK NO: 107 TICKET NO: 19 AIR CONTENT 5.2 UNIT WEIGHT (pci): NA OVERALL PLACEMENT LOCATION: South half of east fire lane and parking area, southeast comer of building SAMPLE LOCATION: East fire lane, 20' south of north header AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 93170 111225 116585 Average 2 4 Hold Does not comply with specified strength. 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 3290 192917 037333 08/21/2003 10/17/2003 3930 4120 4030 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the spccific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 011)13 Page 2 of 5 Ro gin is Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. Duke Realty Services, LP Potter On site MEASURED SLUMP (inches) DATE TESTED 3 1 4.0 08/28/2003 3 2 4.0 3 3 4.0 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 09/18/2003 09/18/2003 3 4 Hold Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:50am REPORT OF TESTS AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 98490 130800 123185 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. BATCH TIME: 10:25am TEMPERATURE (F) AIR 85 F CONCRETE 89 F TRUCK NO: 1 13 TICKET NO: 30 AIR CONTENT 4.9 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: South half of east fire lane and parking area, southeast corner of building SAMPLE LOCATION: East fire lane, 200' south of north header COMPRESSIVE STRENGTH (Psi) 3480 4630 4360 4500 192917 037333 08/21/2003 10/17/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 0 IDD Page 3 of 5 RoneEngineers to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: ASTM C-172 ASTM C -31 CYLINDER MARKED SET NO. ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 4 1 4.5 08/28/2003 4 2 4.5 09/18/2003 4 3 4.5 09/18/2003 4 4 Hold Water added at site: 10 gallons 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 12:OOpm BATCH TIME: 11:26am TEMPERATURE (F) AIR 90 F CONCRETE: 90 F TRUCK NO: 1 14 TICKET NO: 38 AIR CONTENT 5.1 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: South half of east fire lane and parking area, southeast comer of building REPORT OF TESTS SAMPLE LOCATION: East fire lane, 300' south of north header Concrete Compressive Cylinder 6" x 12" (area 28 27 sq in.) AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 94370 122520 128265 Average COMPRESSIVE STRENGTH (Psi) 192917 037333 08/21/2003 10/17/2003 FRACTURE TYPE 3340 Unbonded Cap 4330 Unbonded Cap 4540 Unbonded Cap 4440 LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 4 of 5 Ro gin is Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: Freeport 10 500 Freeport Parlcway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR 3% 6% TEST METHOD: CYLINDER MARKED SET NO. 5 1 4.25 5 2 4.25 5 3 4.25 5 4 Technician: Lanny Gist Report Distribution: (I) Duke Realty Services, LP (I) Duke Realty Services, LP (I) City of Coppell Engineering Dept. (1) Potter Concrete Duke Realty Services, LP Potter On site ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 08/28/2003 09/18/2003 09/18/2003 Hold 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) Started: 6:30am (I) Pacheco Koch Consulting Engineers (I) Engineering Analyst (1) City of Coppell Bldg. Inspections Report No.: Project No.: Date of Service: Report Date: 192917 037333 08/21/2003 10/17/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/21/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 2:3Opm BATCH TIME: NA TEMPERATURE (F) AJR 99 F CONCRETE: 101 F TRUCK NO: NA TICKET NO: NA AIR CONTENT 4.2 OVERALL PLACEMENT LOCATION: East fire lane SAMPLE LOCATION: 25' north of north header REPORT OF TESTS AGE (days) 7 28 28 Finished: 4:OOpm MAXIMUM LOAD (Ibs. force) 129525 149865 151415 Average UNIT WEIGHT (pct): NA COMPRESSIVE STRENGTH (Psi) 4580 5300 5350 5330 Scott Watson, AET CMT Operations Manager FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 5 of 5