Freeport NIP(7.0)-LR031020RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. 1 1 1 AIR Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Duke Realty Services, LP Potter On site 3% 6% AIR CONTENT 3.5 UNIT WEIGHT (pct): NA MEASURED SLUMP (inches) DATE TESTED 1 4.0 08/29/2003 2 4.0 09/19/2003 3 4.0 09/19/2003 1 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (His. force) 120535 133700 132270 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.:. 7752 PLACEMENT DATE: 08/22/2003 WEATHER CONDITIONS: clear TIME SAMPLED: 7:3Oam BATCH TIME: NA TEMPERATURE (F) AIR 80 F CONCRETE: 88 F TRUCK NO: NA TICKET NO: 114 OVERALL PLACEMENT LOCATION: East fire lane and parking area at NE corner of building SAMPLE LOCATION: NE parking area, 20' east and 10' north of the SW corner COMPRESSIVE STRENGTH (Psi) 4260 4730 4680 4710 192975 037333 08/22/2003 10/20/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMTFATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 6 RoneEngineers to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MEASURED SLUMP DATE (inches) TESTED 3.5 08/29/2003 3.5 09/19/2003 3.5 09/19/2003 2 4 Hold Water added at site: 10 gallons PROJECT DATA REPORT OF TF,STS 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: 192975 037333 08/22/2003 10/20/2003 MIX DESIGN LD 7752 PLACEMENT DATE: 08/22/2003 WEATHER CONDITIONS: clear TIME SAMPLED: 9:05am BATCH TIME: 8:28am TEMPERATURE (F) AIR 84 F CONCRETE: 89 F TRUCK NO: 104 TICKET NO: 75 AIR CONTENT 3.2 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: East fire lane and parking area at NE comer of building SAMPLE LOCATION: East fire lane, 125' S of the NE corner of the building AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 115480 134200 143275 Average COMPRESSIVE STRENGTH (Psi) 4750 5070 4910 FRACTURE TYPE 4080 Unbonded Cap Unbonded Cap Unbonded Cap LA9TATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 6 RoneEngineers to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 3 1 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 5.0 Concrete Compressive Cylinder 6" x 12" (area 28 27 sq in.) DATE TESTED 08/29/2003 3 2 5.0 09/19/2003 3 3 5.0 09/19/2003 3 4 Hold Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 192975 037333 08/22/2003 10/20/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/22/2003 WEATHER CONDITIONS: clear TIME SAMPLED: 10:4Oam BATCH TIME: 10:1 82E1 TEMPERATURE (F) AIR 86 F CONCRETE: 90 F TRUCK NO: 104 TICKET NO: 78 AIR CONTENT ("G): 4.2 UNIT WEIGHT (pci): NA OVERALL PLACEMENT LOCATION: East fire lane and parking area at NE corner of building SAMPLE LOCATION: East fire lane, 30' N of NE corner of the building AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 93515 113475 113985 Average COMPRESSIVE STRENGTH (Psi) 3310 4010 4030 4020 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 3 of 6 RoneEngineers Client: Duke Realty Services, LP Attn. Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 4 1 4 2 4 3 CONCRETE COMPRESSIVE STRENGTH TEST Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compre samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS MEASURED SLUMP (inches) 4 4 4.5 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 PROJECT DATA SAMPLE LOCATION: 15' E and 10' S of the NW corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 4.5 08/29/2003 4.5 09/19/2003 4.5 09/19/2003 10/17/2003 MIX DESIGN LD.: 7752 PLACEMENT DATE: 08/22 WEATHER CONDITIONS: Clear TIME SAMPLED- 12:1 Opm BATCH TIME: 1 1:47am TEMPERATURE (F) AIR 88 F CONCRETE: 90 F TRUCK NO: 114 TICKET NO: 86 AIR CONTENT 4.7 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of south parking lot, Building column line MM to NN AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 87065 109105 109570 Average 116840 Does not comply with specified strength. 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 192975 037333 08/22/2003 10/20/2003 les and bring FRACTURE TYPE Unbonded Cap nbonded Cap nbonded Cap 4130 Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 4 of 6 RoneEngineers to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 5 1 5 5 2 3 Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 5.0 08/29/2003 5.0 09/19/2003 5.0 09/19/2003 5 4 Hold PROJECT DATA SAMPLE LOCATION: 10' N and 10' W of the SE corner REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 81250 110445 116395 Average Does not comply with specified strength. Technician Time: 6:30am 11:30am and 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform requ field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 08/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 1:3 Spm BATCH TIME: 1:O9pm TEMPERATURE (F) AIR 92 F CONCRETE: 91 F TRUCK NO: 104 TICKET NO: 97 AIR CONTENT 4.2 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: North half of south parking lot, Building column line MM to NN COMPRESSIVE STRENGTH (psi) 2870 3910 4120 4020 192975 037333 08/22/2003 10/20/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 5 of 6 Report No.: 192975 Project No.: 037333 Client: Duke Realty Services, LP 12:OOpm 2:45pm Water added at site: 10 gallons Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept (1) Potter Concrete Started: Finished: (I) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections RoneEngineers El eiliPSAIA K. Scott t atson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. I1DD Page 6 or6