Loading...
Freeport NIP(7.0)-LR031021Ro gin vs Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQU STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 2 1 3 Duke Realty Services, Potter On site IRE MENTS 4000 psi 28 Days 5" maximum 3% -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 Water added at site: 10 gallons LP MEASURED SLUMP DATE (inches) TESTED 4.0 09/29/2003 4.0 10/20/2003 4.0 10/20/2003 1 4 Hold 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 5:2Oam BATCH TIME: 4:45am TEMPERATURE (F) AIR 70 F CONCRETE: 80 F TRUCK NO: 114 TICKET NO: 348 AIR CONTENT (90): 4.5 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: Parking lot, southwest comer of building REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) SAMPLE LOCATION: 10' north, 10' west of southwest corner of building AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 123575 145580 146610 Average COMPRESSIVE STRENGTH (psi) 4370 194925 037333 09/22/2003 10/21/2003 5150 5180 5170 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 5 Ro i n Client: Duke Realty Services, LP Attn: Mr Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 CONCRETE COMPRESSIVE STRENGTH TEST Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum 3% -6% ASTM C -172 ASTM 031 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 2 4 Hold PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 6:OOam BATCH TIME: 5:41am TEMPERATURE (F) AIR 70 F CONCRETE: 81 F TRUCK NO: 113 TICKET NO: 356 AIR CONTENT 4.0 UNIT WEIG OVERALL PLACEMENT LOCATION: Parking lot, southwest corner of building REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MEASURED SLUMP DATE (inches) TESTED 4.5 09/29/2003 4.5 10/20/2003 4.5 10/20/2003 SAMPLE LOCATION: 50' west, 30' no thwest corner of building AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 125510 151560 155370 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (Psi) 4440 194925 037333 09/22/2003 10/21/2003 5360 5490 5430 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 2 of 5 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services- CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): 5" maximum AIR( 3% 6 TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. 3 1 3 2 3 3 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MEASURED SLUMP (inches) 5.0 5.0 5.0 3 4 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN LD.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:OOam BATCH TIME: 6:4Oam TEMPERATURE (F) AIR 68 F CONCRETE: 82 F TRUCK NO: 101 TICKET NO: 366 AIR CONTENT 4.7 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Parking lot, southwest corner of building REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28 27 sq in.) DATE TESTED 09/29/2003 10/20/2003 28 10/20/2003 28 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: Project No.: Date of Service: Report Date: 194925 037333 09/22/2003 10/21/2003 SAMPLE LOCATION: 100' north, 50' west of southwest comer of building AGE (days) 7 MAXIMUM LOAD (lbs. force) 107085 132810 131830 Average COMPRESSIVE STRENGTH (psi) 3790 4700 4660 4680 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 3 of 5 Ro =Min Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR (%n): TEST METHOD: CYLINDER MARKED SET NO. 4 1 4 2 4 3 Duke Realty Services, LP Potter On site 4000 psi 28 Days 5" maximum 3% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 4.5 4.5 4.5 DATE TESTED 09/29/2003 10/20/2003 10/20/2003 4 4 Hold Water added at site: 10 gallons REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 136160 135380 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: MAXIMUM COMPRESSIVE LOAD STRENGTH (lbs. force) (PW) 108145 3820 194925 037333 09/22/2003 10/21/2003 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7'50a111 BATCH TIME: 7:32am TEMPERATURE (F) AIR 70 F CONCRETE: 80 F TRUCK NO: 1 TICKET NO: 376 AIR CONTENT 5.1 UNIT WEIGHT (pet): NA OVERALL PLACEMENT LOCATION: Parking lot, southwest corner of building SAMPLE LOCATION: 125' west, 10' north of southwest corner of building 4820 4790 4810 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rolle Engineers, Ltd. 01DD Page 4 of 5 Ro sin Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONCRETE COMPRESSIVE STRENGTH TEST Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 5 4 MEASURED SLUMP (Inches) 5 1 5.0 5 2 5.0 5 3 5.0 Technician: Lanny Gist Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete 4000 psi 28 Days 5" maximum 3 -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 09/29/2003 10/20/2003 10/20/2003 Hold PROJECT DATA MIX DESIGN 1A.: 7752 PLACEMENT DATE: 09/22/2003 WEATHER CONDITIONS Clear TIME SAMPLED: 9:OSam BATCH TIME: 8:24am TEMPERATURE (F) AIR 72 F CONCRETE: 82 F TRUCK NO: 101 TICKET NO: 386 AIR CONTENT (9o): 4.7 Started: 5:30am (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections OVERALL PLACEMENT LOCATION: Parking lot, southwest corner of building 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rollaway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 194925 037333 09/22/2003 10/21/2003 UNIT WEIGHT (pcf): NA SAMPLE LOCATION: 150' west, 75' north of southwest corner of building AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 103300 125835 128440 Average Finished: 10:30am COMPRESSIVE STRENGTH (Psi) 3650 4450 4540 4500 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 5 of 5