Loading...
Assured Self-LR030805ALPHA TESTING, INC. 2209 Wisconsin St., sulte,~ Concrete Compression Test ~~~~~ Dallas, Texas 75229 Report (972) 620-8911 Tested For: ASSURED SELF STORAGE ATTN: RON VALK 1001 W. PLEASANT RUN ROAD DESOTO.TX 75115 Fax Number: (972) 223-2606 Project Dese: ASSURED SELF STORAGE FACILITY 1751 EAST BELTLINE ROAD Our Report No.: 03373-13 Issue Date: OSI05/2003 FIELD DATA Placement Location: SLAB, BUILDING L Dale Placed: Time Placed: Slump (ASTM C-143): Air Content: Air Temperature: Specimen Temperature: Data ReceNed: Delivery Method: Field Data Submitted By: Mlx Data Submitted By: 7I3I03 NIA NIA NIA NIA N/A 7/BI03 PICKED UP BY ALPHA NIA Plant Number: N/A Delivery Ticket No.: N/A Made ey: Cured 3peciflcatlon: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depthl Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 12 LAB C-1231 7/31/03 28 12 N/A 6 28.27 109926 3880 Saeclflcatlona: 28 3000 Notes: CLIENT MADE CYLINDERS. CC: ASSURED SELF STORAGE, CITY OF COPPELL Respecdully Submitted of Alpha Testing, Inc. Our ust resulo and reDerts are for she excluske use of the Client (and their designated receplenu on flte In our office) and shall not be reproduced and/or dlsvibuud except with expreu approval of ALPHA. The use of our name and [es[ resulo must receive our written approval. Tes[ resulo and reports apply only to the samples tested and/or oburved, and are not Indlutlve of the qualltles of apparently Identlcal or similar specimens. Geotechnlcal Engineering' Construction Materials Testing' Environmental Engineering' Consulting 25537 ALPHA TESTING, iNC. Concrete Compression Test 2209 Wisconsin St., Suite 10 ~~~/r Dallas, Texas 75229 Report / (972)620-8911 Tested For: ASSURED SELF STORAGE ATTN: RON VALK 1001 W. PLEASANT RUN ROAD DESOTO, TX 75115 Fax Number: (972) 223-2606 Project Desc: ASSURED SELF STORAGE FACILITY 1751 EAST BELTLINE ROAD Our Repoli No.: 03373-14 Issue Date: OBI05/2003 FIELD DATA Plawment Loeatlon: SLAB, BUILDING K Date Placed: Time Placed: Slump (ASTM C-143): Air Content: Atr Temperature: Specimen Temperature: Date Received: Delivery Method: Field Data Submitted By: Mix Data Submitted By: 713/03 NIA NIA NIA NIA NIA 7/8/03 PICKED UP BY ALPHA NIA Plant Number: N/A Delivery Ticket No.: N/A Made By: Cured Speciflcatlon: ASTM C-31 CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Dlamater Sq. In. Load: PSI: 13 LAB C-1231 7/31/03 28 12 N/A 6 28.27 74121 2620 ~ - Speciflcatlona: 28 3000 Results to Date: FAIL BY 13% I Notes: CLIENT MADE CYLINDERS. CC: ASSURED SELF STORAGE, CITY OF COPPELL Respectfully Submitted of Alpha Testing, Inc. Our test resulu and reporo are for the exclusive use of dte Cllfn[ (and their designated receplents on Flle in our office) and shall not be reproduced and/or dlsWbuted except with express approval of ALPHA. The use of our name and test resulu must receive our written approval. Test resulu and reports apply only to the samples tested and/or observed, and are no[ IndlcaWe of the qualities of apparently Idendcal or similar specimens. Geotechnical Engineering' Construction Materials Testing' Environmental Engineering • Consulting 25538