Coppell CC 1B1-LR010907ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CONCRETE INSPECTION AND COMPRESSION TEST REPORT CLIENT: Koll Development Company REPORT DISTRIBUTION: PROJECT: Kolf Center -Coppell Koll Development Company -James Williams REPORT DATE: 9/7/01 Hill & Wilkerson, Inc. -Kirk Woltman AGG REPORT #: C01-0206-247 Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS PROJECT DATA Strength (psi): 4000 Placement Date: 8/27/01 Slump (in.): 3 to 5 Sampled By: Joe Espinosa Air Content (%): 3.5 to 6.5 Weather: Partly Cloudy -Fair Concrete Temp (°F): 95 max Supplier/Mix: Hanson - 7752 FIELD DATA SET #1 Ticket #: 808820 Time Batched: 4:25 a.m. Time Sampled: 4:50 a.m. Slump (in.): 4.50 Air Content: 4.8 Unit Weight (pcf): na Conc. Temp. (°F): 75 Ambient Temp. (°F): 73 Yardage (c.y.): 50 of 100 Placement Location: 70' Northeast of the Northeast Corner of Building #2 Remarks: FIELD DATA SET #2 Ticket #: 808837 Time Batched: 6:12 a.m. Time Sampled: 6:45 a.m. Slump (in.): 5.00 Air Content: 5.0 Unit Weight (pcf): na Conc. Temp. (°F): 78 Ambient Temp. (°F): 76 Yardage (c.y.): 10 of 200 Placement Location: 70' Northeast of Center of Building #2 Remarks: CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39 Set # C tinder # Test Date A e Da s Max. Load Ibs Area sq. in. Stren th si FC Notes A 9/3/01 7 98920 28.27 3500 C 1 B 9/3/01 7 99200 28.27 3510 D C 9/24/01 28 28.27 D 9/24/01 28 2827 E Hold A 913/01 7 92530 28.27 3270 C 2 B 9/3/01 7 94190 28.27 3330 C C 9/24/01 28 28.27 D 9/24/01 28 28.27 E Hold (1) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, B=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231 Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without LLIANCE GEOTECHNICAL GROUP the written consent of AGG. Results apply only to above tests. ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Sfreef, Suife 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CONCRETE INSPECTION AND COMPRESSION TEST REPORT CLIENT: Koll Development Company REPORT DISTRIBUTION: PROJECT: Koll Center -Coppell Koll Development Company -James Williams REPORT DATE: 9/7/01 Hill & Wilkerson, Inc. -Kirk Woltman AGG REPORT #: C01-0206-247 Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS PROJECT DATA Strength (psi): 4000 Placement Date: Slump (in.): 3 to 5 Sampled By: Air Content (%): 3.5 to 6.5 Weather: Concrete Temp (°F): 95 max Supplier/Mix: 8/27/01 Joe Espinosa Partly Cloudy -Fair Hanson - 7752 FIELD DATA SET #3 Ticket #: 808849 Time Batched: 7:20 a.m. Time Sampled: 8:25 a.m. Slump (in.): 5.50* Air Content: 5.0 Unit Weight (pcf): na Conc. Temp. (°F): 80 Ambient Temp. (°F): 79 Yardage (c.y.): 10 of 310 Placement Location: 70' Northeast of East Side of Building #2 Remarks: `Contractor was notified of slump being out of project specifications. FIELD DATA SET #4 Ticket #: Slump (in.): Conc. Temp. (°F): Placement Location: Remarks: 808863 5.75* Time Batched: 8:05 a.m Air Content: 5.3 85 Ambient Temp. (°F): 83 70' Northeast of the Southeast Corner Building #2 out of Time Sampled: 9:50 a.m. Unit Weight (pcf): na Yardage (c.y.): 10 of 380 CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39 Set # C tinder # Test Date A e Da s Max. Load Ibs Areas . in. Stren th si FC Notes A 9/3/01 7 96120 28.27 3400 D 3 B 9/3/01 7 92290 28.27 3260 D C 9/24/01 28 28.27 D 9/24/01 28 28.27 E Hold A 9/3/01 7 112390 28.27 3980 B 4 B 9/3/01 7 111050 28.27 3930 C C 9/24/01 28 28.27 D 9/24/01 28 28.27 E Hold (1) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, B=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C138, Ct43, C172, C231 Note: This report is for the exclusive use of the Client addressed. ~/i~ This report may not be reproduced except in its entirety, without LIANCE GEOTECHNICAL GROUP the written consent of AGG. Results apply only to above tests.