Coppell CC 1B1-LR010905ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CONCRETE INSPECTION AND COMPRESSION TEST REPORT CLIENT: Koll Development Company REPORT DISTRIBUTION: PROJECT: Koll Center -Coppell Koll Development Company -James Williams REPORT DATE: 9/5/01 Hill & Wilkerson, Inc. -Kirk Woltman AGG REPORT #: C01-0206-221 Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS PROJECT DATA Strength (psi): 4000 Placement Date: 8/7/01 Slump (in.): 5 max Sampled By: D. Vandergriff Air Content (%): 3.5 to 6.5 Weather: Partly Cloudy Concrete Temp (°F): 95 max Supplier/Mix: Potter - 7752 FIELD DATA SET #1 Ticket #: 613678 Time Batched: 8:22 a.m. Time Sampled: 9:00 a.m. Slump (in.): 4.25 Air Content: 6.0 Unit Weight (pcf): na Conc. Temp. (°F): 90 Ambient Temp. (°F): 87 Yardage (c.y.): 50 Placement Location: Paving area 30' E. and 20' S. of SW corner of building #2 Remarks: FIELD DATA SET #2 Ticket #: Slump (in.): Conc. Temp. (°F): Placement Location: Remarks: 613687 Time Batched: 9:14 a.m 5.25* Air Content: 6.0 91 Ambient Temp. (°F): 88 Paving area 90' W. and 30' S. of SE corner of bu' *SlumD exceeds #2 Time Sampled: Unit Weight (pcf): Yardage (c.y.): 10:00 a.m. na 140 CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C37, TESTED PER ASTM C39 Set # C tinder # Test Date A e (Da s Max. Load Ibs Area (s . in. Stren th si FC Notes A 8/14/01 7 118300 28.27 4180 B 1 B 8/14/01 7 107860 28.27 3820 C C 9/4/01 28 140330 28.27 4960 C D 9/4/01 28 147310 28.27 5210 C E Discard A 8/14/01 7 110080 28.27 3890 C 2 B 8/14/01 7 108410 28.27 3830 C C 9/4/01 28 136220 28.27 4820 D D 9/4/01 28 133090 28.27 4710 C E Discard (1) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, 6=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231 Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without the written consent of AGG. Results apply only to above tests. /'-'~ ANCE GEOTECHNICAL GROUP ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CONCRETE INSPECTION AND COMPRESSION TEST REPORT CLIENT: Koll Development Company REPORT DISTRIBUTION: PROJECT: Koll Center -Coppell Koll Development Company -James Williams REPORT DATE: 9/5/01 Hill & Wilkerson, Inc. -Kirk Woltman AGG REPORT #: C01-0206-221 Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS PROJECT DATA Strength (psi): 4000 Placement Date: 8/7/01 Slump (in.): 5 max Sampled By: D. Vandergriff Air Content (%): 3.5 to 6.5 Weather: Partly Cloudy Concrete Temp (°F): 95 max Supplier/Mix: Potter - 7752 FIELD DATA S ET #3 Ticket #: 613698 Time Batched: 10:38 a.m. Time Sampled: 11:15 a.m. Slump (in.): 5.00 Air Content: 6.5 Unit Weight (pcf): na Conc. Temp. (°F): 91 Ambient Temp. (°F): 90 Yardage (c.y.): 250 Placement Location: Pavinq Area 30' E and 40' S. of SE corner of building #2 Remarks: FIELD DATA SET #4 Ticket #: 613706 Time Batched: 11:23 a.m. Time Sampled: 12:15 p.m. Slump (in.): 5.00 Air Content: 6.2 Unit Weight (pcf): na Conc. Temp. (°F): 91 Ambient Temp. (°F): 94 Yardage (c.y.): 350 Placement Location: Paving Area 75' W and 30' S. of SW corner of buildin g #1 Remarks: CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39 Set # C tinder # Test Date A e Da s) Max. Load Ibs Areas . in. Stren th si FC Notes A 8/14/01 7 102690 28.27 3630 D 3 B 8/14/01 7 101410 28.27 3590 D C 9/4/01 28 142030 28.27 5020 D D 9/4/01 28 139230 28.27 4930 C E Discard A 8/14/01 7 103640 28.27 3670 D 4 B 8/14/01 7 102490 28.27 3630 C C 9/4/01 28 131050 28.27 4640 D D 9/4/01 28 127330 28.27 4500 C E Discard (1) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, B=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231 Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without LL ANCE GEOTECHNICAL GROUP the written consent of AGG. Results apply only to above tests.