Coppell CC 1B1-LR010815ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CLIENT: PROJECT: REPORT DATE: AGG REPORT #: CONCRETE INSPECTION AND COMPRESSION TEST REPORT Koll Development Company Koll Center -Coppell 08/15/01 C01-0206-187 REPORT DISTRIBUTION: Koll Development Company -James Williams Hill & Wilkerson, Inc. -Kirk Woltman Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS PROJECT DATA Strength (psi): Slump (in.): Air Content (%): 4000 5 max 3.5 - 6.5 Concrete Temp (°F): 95 max Placement Date: Sampled By: Weather: Supplier/Mix: 07/16/01 D. Vandergriff Sunny Potter-7752 FIELD DATA SET #1 Ticket #: 612964 Time Batched: 7:05 a.m. Time Sampled: 7:45 a.m. Slump (in.): 5.00 Air Content: 6.2 Unit Weight (pct): na Conc. Temp. (°F): 85 Ambient Temp. (°F): 82 Yardage (c.y.): 40 Placement Location: Paving area on south side of building #1, 50' E. & 50' S. of SE corner Remarks: FIELD DATA SET #2 Ticket #: 612973 Time Batched: 8:10 a.m. Time Sampled: 9:00 a.m. Slump (in.): 5.5' Air Content: 6.0 Unit Weight (pcf): na Conc. Temp. (°F): 90 Ambient Temp. (°F): 87 Yardage (c.y.): 130 Placement Location: Paving area 25' S. & 50' E. of SW of building #1 Remarks: 'Slump exceeds s pecifications CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C37, TESTED PER ASTM C39 Set # C tinder # Test Date A e Da s Max. Load Ibs Areas . in. Stren th si FC Notes A 07/23/01 7 89120 28.27 3150 D 1 B 07/23/01 7 88350 28.27 3130 B C 08/13/01 28 115580 28.27 4090 C D 08/13/01 28 116480 28.27 4120 D E Hold A 07/23/01 7 79810 28.27 2820 D 2 B 07/23/01 7 79100 28.27 2800 B C 08/13/01 28 101930 28.27 3610 D D 08/13/01 28 103640 28.27 3670 C `Does nat meet specs. E 09/10/01 56 (1) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, B=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C136, C143, C172, C231 Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without the written consent of AGG. Results apply only to above tests. ~~ LIANCE GEOTECHNICAL GROUP ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CLIENT: PROJECT: REPORT DATE: AGG REPORT #: CONCRETE INSPECTION AND COMPRESSION TEST REPORT Koll Development Company Koll Center -Coppell 08/15/01 C01-0206-187 REPORT DISTRIBUTION: Koll Development Company -James Williams Hill & Wilkerson, Inc. -Kirk Woltman Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS PROJECT DATA Strength (psi): 4000 Slump (in.): 5 max Air Content (%): 3.5 - 6.5 Concrete Temp (°F): 95 max Placement Date: 07/16/01 Sampled By: D. Vandergriff Weather: Sunny Supplier/Mix: Potter - 7752 FIELD DATA SET #3 Ticket #: Slump (in.): Conc. Temp. (°F): Placement Location: Remarks: 612983 Time Batched: 9:30 a.m. Time Sampled: 10:15 a.m. 5.00 Air Content: 5.7 Unit Weight (pcf): na 92 Ambient Temp. (°F): 90 Yardage (c.y.): 230 Pavino area 65' S. & 20' E. of SW of building #1 FIELD DATA SET #4 Ticket #: 612992 Time Batched: 10:27 a.m. Time Sampled: 11:45 a.m. Slump (in.): 6.0' Air Content: 4.1 Unit Weight (pcf): na Conc. Temp. (°F): 91 Ambient Temp. (°F): 95 Yardage (c.y.): 320 Placement Location: Paving area 10' E. & 35' N. of NW of building #3 Remarks: 'Slump exceeds s pecifications CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39 Set # C tinder # Test Date A e Da s Max. Load Ibs Areas . in. Stren th si FC Notes A 07/23/01 7 82620 28.27 2920 D 3 B 07/23/01 7 86880 28.27 3070 D C 08/13/01 28 114620 28.27 4050 C D 08/13/01 28 117090 28.27 4140 D E Hold A 07/23/01 7 85880 28.27 3040 D 4 B 07/23/01 7 83300 28.27 2950 D C 08/13/01 28 109410 28.27 3870 C D 08/13/01 28 106970 28.27 3780 D * Does not meet specs. E 09/10/01 56 (1) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, B=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C138, C143, C172, C231 ~1 Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without the written consent of AGG. Results apply only to above tests. ALLIANCE GEOTECHNICAL GROUP GEOTECHNICAL AND CONSTRUCTION MATERIALS ENGINEERING AND TESTING 10610 Newkirk Street, Suite 202, Dallas, Texas 75220 Phone: 972-444-8889 Fax: 972-444-8893 CONCRETE INSPECTION AND COMPRESSION TEST REPORT CLIENT: PROJECT: REPORT DATE: AGG REPORT #: Koll Development Company Koll Center -Coppell 08/15/01 C01-0206-187 SPECIFICA REPORT DISTRIBUTION: Koll Development Company -James Williams Hill & Wilkerson, Inc. -Kirk Woltman Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige BDD, Inc. -Russell Williams City of Coppell -Lee Stone of Strength (psi): 4000 Placement Date: Slump (in.): 5 max Sampled By: Air Content (%): 3.5 - 6.5 Weather: Concrete Temp (°F): 95 max Supplier/Mix: FIELD DATA SET #6 Time Batched: _ Air Content: _ Ambient Temp. (°F): FIELD DATA SET #5 Ticket #: 613005 Time Batched: 1:55 p.m. Time Sampled: 2:45 p.m. Slump (in.): 4.50 Air Content: 5.1 Unit Weight (pc0: na Conc. Temp. (°F): 92 Ambient Temp. (°F): 97 Yardage (c.y.): 430 Placement Location: Approach on west side of building #3 from Freeport Parkway Remarks: Ticket #: Slump (in.): Conc. Temp. (°F): Placement Location: Remarks: Davis PROJECT DATA Time Sampled: Unit Weight (pcf): Yardage (c.y.): 07/16/01 D. Vandergriff Sunny Potter - 7752 CONCRETE COMPRESSION TEST RESULTS CYLINDERS MOLDED AND CURED PER ASTM C31, TESTED PER ASTM C39 Set # C tinder # Test Date A e Da s Max. Load Ibs Areas . in. Stren th si FC Notes A 07/23/01 7 71460 28.27 2530 D 5 B 07/23/01 7 73040 28.27 2580 D C 08/13/01 28 93770 28.27 3320 D D 08/13/01 28 94650 28.27 3350 C 'Does not meet specs. E 09/10/01 56 6 (t) NORMAL CYLINDER SIZE 6" X 12", AREA 28.27 sq. in., UNLESS NOTED ABOVE. (2) FAILURE TYPE A=CONE, 6=CONE AND SPLIT, C=CONE AND SHEAR, D=SHEAR, E=COLUMNAR (3) TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS UNLESS INDICATED IN NOTES. (4) FIELD TESTS ARE PER APPLICABLE ASTM STANDARDS: C136, C143, C172, C231 Note: This report is for the exclusive use of the Client addressed. This report may not be reproduced except in its entirety, without the written consent of AGG. Results apply only to above tests.