Loading...
Coppell CC 1B1-LR010518ALLIANCE GEOTECHNICAL GROUP, INC. GEOTECHNICAL AND CONSTRUCTION MATERIALS TESTING & ENGINEERING 10610 Newkirk Street Suite #202 Dallas, Texas 75220 Phone 972-444-8889 Fax 972-444-8893 SOIL MOISTURE -DENSITY TEST REPORT IN-PLACE TESTS BY NUCLEAR METHODS (ASTM D 2922) CLIENT: Koll Development Company DISTRIBUTION: PROJECT: Koll Center -Coppell Koll Development Company -James Williams REPORT DATE: 5/18/01 Hill & Wilkerson, Inc. -Kirk Woltman AGG REPORT #: C01-0206-082 Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS TEST DATA Compaction: 95% Date Tested: 5/15/01 Moisture: -2 t0 +2 Technician: D. Vandergflff MATERIAL REFERENCE CURVE DATA CURVE NO. TEST METHOD MATERIAL DESCRIPTION OPTIMUM MOISTURE MAX. DRY DENSITY (pcf) 488 ASTM D 698 Reddish Brown Cla a Sand -Select Fitl 13.0 117.6 636 ASTM D 698 Yellowish Sand w/traces of Cla Balls & S.S. Fra ments -Select Fill 15.1 111.4 IN-PLACE TEST RESULTS TEST NO. ELEVATION OR LIFT LOCATION REF. CURVE % MOISTURE DRY DENSITY MOISTURE DEVIATION DENSITY 1 1st Waterline in Building #2 E to W Line, 75' from E Ed a 636 16.9 106.2 + 1.8 95.3 2 2nd Waterline in Building #2 E to W Line, 45' from E Ed a 488 14.7 114.6 + 1.7 97.4 3 3rd Waterline in Building #2 E to W Line, 35' from E Ed a 636 15.1 109.8 + 0.0 98.6 DOES NOT COMPLY WITH PROJECT SPECIFICATIONS Notes: ALLIANCE GEOTECHNICAL GROUP, INC. ALLIANCE GEOTECHNICAL GROUP, INC. GEOTECHNICAL AND CONSTRUCTION MATERIALS TESTING & ENGINEERING 10610 Newkirk Street Suite #202 Dallas, Texas 75220 Phone 972-444-8889 Fax 972-444-8893 SOIL MOISTURE -DENSITY TEST REPORT IN-PLACE TESTS BY NUCLEAR METHODS (ASTM D 2922) CLIENT: Koll Development Company DISTRIBUTION: PROJECT: KOII Center -Coppell Koll Development Company -James Williams REPORT DATE: 5/18/01 Hill & Wilkerson, Inc. -Kirk Woltman AGG REPORT #: C01-0206-085 Alliance Architects -Tom Maxwell AECC, Inc. -Andy Brundige City of Coppell -Lee Stone City of Coppell -Larry Davis SPECIFICATIONS TEST DATA Compaction: 95% Moisture: -2 to +2 Date Tested: Technician: MATERIAL REFERENCE CURVE DATA CURVE NO. TEST METHOD MATERIAL DESCRIPTION OPTIMUM MOISTURE MAX. DRY DENSITY (pcf) 488 ASTM D 698 Reddish Brown Cla a Sand -Select Fill 13.0 117.6 636 ASTM D 698 Yellowish Sand w/traces of Cla Balls & S.S. Fra ments -Select Fill 15.1 111.4 IN-PLACE TEST RESULTS TEST NO. ELEVATION OR LIFT LOCATION REF. CURVE % MOISTURE DRY DENSITY MOISTURE DEVIATION DENSITY 1 4th Waterline in Building #2 E to W Line, W from E Ed a 488 14.9 111.9 + 1.9 95.2 2 5th Waterline in Building #2 E to W Line, W from E Ed a 636 15.5 106.1 + 0.4 95.2 3 1st Waterline in Building #2 N to S Line, 100' of "T" 636 15.3 106.5 + 0.2 95.6 4 2nd Waterline in Building #2 N to S Line, 50' of "T" 636 15.2 106.7 + 0.1 95.8 5 1st Waterline in Building #2 N to S Line, 100' S of "T" 488 14.5 112.4 + 1.5 95.6 6 2nd Waterline in Building #2 N to S Line, 50' S of "T" 636 15.7 106.0 + 0.6 95.2 'DOES NOT COMPLY WITH PROJECT SPECIFICATIONS Notes: ALLIANCE GEOTECHNICAL GROUP, INC.