Freeport NIP(7.0)-LR031104RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Hanson PLANT: 27 SPECIFICATION REQUIREMENTS STRENGTH: 3500 psi 28 Days SLUMP (in): 5" maximum AIR 4% 6% TEST METHOD: ASTM C-172 ASTM C -31 CYLINDER MARKED SET NO. 1 1 4 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 1 4.25 11/03/2003 7 2 4.25 11/24/2003 28 3 4.25 11/24/2003 28 4.25 12/22/2003 56 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN LD.: 7752 PLACEMENT DATE: 10/27/2003 WEATHER CONDFFIONS: Clear TIME SAMPLED: 5:2Oam BATCH TIME: 4:41 am TEMPERATURE (F) AIR 49 F CONCRETE: 78 F TRUCK NO: 1015 TICKET NO: 76485 AIR CONTENT 5.1 UNIT WEIGHT (Pct): NA OVERALL PLACEMENT LOCATION: Paving 350' west, 350' north from southwest comer of building REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE AGE TESTED (days) SAMPLE LOCATION: 120' north, 40' east from southwest corner of paving MAXIMUM LOAD (lbs. force) 113465 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENGTH (psi) 197643 037333 10/27/2003 11/04/2003 FRACTURE TYPE 4010 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 1 of 4 RoneEngineers or Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 2 1 4.75 Duke Realty Services, LP Hanson 27 SPECIFICATION REQUIREMENTS STRENGTH: 3500 psi 28 Days SLUMP (in): 5" maximum AIR 4% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 2 2 4.75 11/24/2003 2 3 4.75 11/24/2003 2 4 4.75 12/22/2003 56 Water added at site: 5 gallons 11/03/2003 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28 27 sq. in.) DATE TESTED 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 197643 037333 10/27/2003 11/04/2003 MIX DESIGN LD.: 7752 PLACEMENT DATE: 10/27/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:1 Oam BATCH TIME: 6:4 I am TEMPERATURE (F) AIR 51 F CONCRETE: 81 F TRUCK NO: 1 883 TICKET NO: 76498 AIR CONTENT 5.4 UNIT WEIGHT (pci: NA OVERALL PLACEMENT LOCATION: Paving 350' west, 350' north from southwest corner of building SAMPLE LOCATION: 115' north, 50' west from southeast comer of paving AGE (days) 7 28 28 MAXIMUM LOAD (Ibs. force) 108840 COMPRESSIVE STRENGTH (Psl) FRACTURE TYPE 3850 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 2 of 4 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: Duke Realty Services, LP Hanson 27 SPECIFICATION REQUIREMENTS STRENGTH: 3500 psi 28 Days SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 5" maximum 4% 6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED 3 1 4.5 11/03/2003 3 2 4.5 11/24/2003 3 3 4.5 11/24/2003 3 4 4.5 12/22/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rotbway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA SAMPLE LOCATION: REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MIX DESIGN LD.: 7752 PLACEMENT DATE: 10/27/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 8:O5am BATCH TIME: 7:35am TEMPERATURE (F) AIR 61 F CONCRETE: 81 F TRUCK NO: 30 AIR CONTENT 5.4 OVERALL PLACEMENT LOCATION: Paving 350' west, 350' north from southwest comer of building AGE (days) 7 28 28 56 MAXIMUM LOAD (Ibs. force) 97125 Report No.: Project No.: Date of Service: Report Date: 197643 037333 10/27/2003 11/04/2003 TICKET NO: 76505 UNIT WEIGHT (pep: NA 40' west, 10' south from northeast comer of paving COMPRESSIVE STRENGTH (Psi) FRACTURE TYPE 3430 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 3 of 4 RoneEngineers is Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Hanson PLANT: 27 SPECIFICATION REQUIREMENTS STRENGTH: 3500 psi 28 Days SLUMP (in): 5" maximum AIR TEST METHOD: CYLINDER MARKED SET NO. Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 4% 6% AIR CONTENT 5.8 UNJT WEIGHT (pcf): NA ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 4 1 5.0 4 2 5.0 4 3 5.0 4 4 5.0 Technician: Jeremy Watts Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (I) City of Coppell Engineering Dept. (I) Potter Concrete Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 11/03/2003 11/24/2003 11/24/2003 12/22/2003 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Started: 4:30am AGE (da 28 56 (I) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections OVERALL PLACEMENT LOCATION: Paving 350' west, 350' north from southwest comer of building Finished: 12:30pm MAXIMUM LOAD (Ibs. force) 96210 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/27/2003 WEATHER CONDIFIONS: Clear TIME SAMPLED: 10:25 am BATCH TIME: 9:3 5 am TEMPERATURE (F) AIR 73 F CONCRETE: 86 F TRUCK NO: 1850 TICKET NO: 76522 SAMPLE LOCATION: 80' west, 40' north from southeast corner of paving COMPRESSIVE STRENGTH (ps 197643 037333 10/27/2003 11/04/2003 K. colt Watson, CMT Operations Manager FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 4 of 4