Loading...
Freeport NIP(7.0)-LR031103RoneEngineers v Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas T 4 Project Services: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: 196233 037333 10/03/2003 11/03/2003 Freeport f I -11t, +t t0 TX Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days MEASURED SLUMP DATE (inches) TESTED 4 %a -6% ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 1 1 6.0 10/10/2003 1 2 6.0 10/31/2003 1 3 6.0 10/31/2003 PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/03/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 5:45 am BATCH TIME: 5:21a TEMPERATURE (F) AIR 59 F CONCRETE: 78 TRUCK NO: 101 TICKET NO: 560 AIR CONTENT 53 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Employee parking lot on west side of building REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) SAMPLE LOCATION: 140' north, 60' west from southwest comer of office building area MAXIMUM LOAD dim. force) 108220 141280 141050 Average COMPRESSIVE STRENGTH (Psi) 3830 1 4 Hold Set 1 and 2 were damaged in the field by the contractor. Specimen 2 -1, 2 -2, and 2 -3 were the only cylinders testable from set 2. All cylinders in set 2 were FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have 110 control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 1 of 6 Report No.: 196233 Project No.: 037333 heavily damaged. Water added at site: 5 gallons Client: Duke Realty Services, LP RoneEngineers LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineers, Ltd. o1DD Page 2 of 6 RoneEngineers to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: Duke Realty Services, LP Potter Concrete On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. MEASURED SLUMP (inches) DATE TESTED 2 1 5.0 10/10/2003 2 2 5.0 10/31/2003 2 3 5.0 10/31/2003 2 4 Hold Does not comply with specified strength. Water added at site: 5 gallons 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS OVERALL PLACEMENT LOCATION: Employee parking lot on west side of building Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 MAXIMUM LOAD (113s. force) 41470 119565 28985 Average Report No.: Project No.: Date of Service: Report Date: Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/03/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 6:SOam BATCH TIME: 6:3lam TEMPERATURE (F) AIR 60 F CONCRETE: 76 F TRUCK NO: 1 15 TICKET NO: 568 4% 6% AIR CONTENT 4.9 UN1T WEIGHT (pct): NA SAMPLE LOCATION: 50' north, 60' west from southwest corner of office area COMPRESSIVE STRENGTH (Psi) 1470 4230 1020 2630 196233 037333 10/03/2003 11/03/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 3 of 6 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CYLINDER MARKED SET NO. 3 1 3 2 3 3 3 4 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 4% 6% AIR CONTENT 5.0 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Employee parking lot on west side of building Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MEASURED SLUMP DATE (inches) TESTED 6.0 10/10/2003 6.0 10/31/2003 6.0 10/31/2003 Hold REPORT OF TESTS SAMPLE LOCATION: 105' west from southwest corner of office building area AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 92950 113620 117890 Average 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 CONCRETE COMPRESSIVE STRENGTH TEST Report No.: Project No.: Date of Service: Report Date: PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/03/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:4Oarn BATCH TIME: 7:22am TEMPERATURE (F) AIR 60 F CONCRETE: 79 F TRUCK NO: 1 TICKET NO: 577 COMPRESSIVE STRENGTH (psi) 196233 037333 10/03/2003 11/03/2003 FRACTURE TYPE 3290 Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. O1DD Page 4 of 6 RoneEngineers or Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compres samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR 4% 6% TEST METHOD: ASTM C -172 ASTM C -31 CYLINDER MARKED SET NO. 4 1 6.0 4 2 6.0 4 3 6.0 4 4 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) DATE TESTED 10/10/2003 10/31/2003 10/31/2003 Hold CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: Project No.: Date of Service: Report Date: 196233 037333 10/03/2003 11/03/2003 ngth samples and bring MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/03/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:OSam BATCH TDVIE: 9:54am TEMPERATURE (F) AIR 63 F CONCRETE: 80 F TRUCK NO: 106 TICKET NO: 591 AIR CONTENT 5.2 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Employee parking lot on west side of building SAMPLE LOCATION: AGE (days) 7 28 28 MAXIMUM LOAD (lbs. force) 102250 116445 120235 Average 75' south from southwest corner of office area of building COMPRESSIVE STRENGTH (Psi) FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 5 of 6 RoneEngineers to Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Potter Concrete PLANT: On site SPECIFICATION REQUIREMENTS STRENGTH: 4000 psi 28 Days SLUMP (in): AIR 4% 6% TEST METHOD: ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 CYLINDER MARKED SET NO. 5 1 5 2 5 3 5 4 CONCRETE COMPRESSIVE STRENGTH TEST Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Technician: Ryan Armstrong Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) MEASURED SLUMP DATE (inches) TESTED 4.75 10/10/2003 4.75 10/31/2003 4.75 10/31/2003 Hold (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 Report No.: Project No.: Date of Service: Report Date: 196233 037333 '10/03/2003 11/03/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/03/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 1 1:OOam BATCH TIME: 10:49am TEMPERATURE (F) AIR 66 F CONCRETE: 83 F TRUCK NO: 101 TICKET NO: 600 AIR CONTENT 4.4 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Employee parking lot on west side of building SAMPLE LOCATION: 140' south from southwest corner of office area of building AGE (days) 7 28 28 Started: 4:30am Finished: 1:30pm MAXIMUM LOAD (lbs. force) 120515 139855 131035 Average COMPRESSIVE STRENGTH (Psi) 4260 4950 4630 4790 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap K. Scott Watson, AET CMT Operations Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01DD Page 6 of 6 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Services: CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 1 1 1 2 1 Freeport 10 500 Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. 3 1 4 Duke Realty Services, LP Hanson 27 3500 psi 28 Days 5" maximum 4% 6% ASTM C -172 ASTM C -3I ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP DATE (inches) TESTED Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) 5.5 10/31/2003 5.5 11/21/2003 5.5 11/21/2003 5.5 12/19/2003 Water added at site: 10 gallons Notified Lupe of slump results. CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 7:35am BATCH TIME: 7:1 Sam TEMPERATURE (F) -AIR 60 F CONCRETE: 71 F TRUCK NO: 104 TICKET NO: 76431 AIR CONTENT 5.5 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Paving 300' west, 150' north from southwest comer of building SAMPLE LOCATION: 15' north, 20' east from southwest REPORT OF TESTS comer of paving AGE (d 28 28 MAXIMUM LOAD (Ibs. force) 95450 8908 Ambassador Row, Dallas, PC 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: COMPRESSIVE STRENG (Ps 197529 037333 10/24/2003 11/03/2003 FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. OIDD Page 1 of 3 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. CONTRACTOR: CONCRETE SUPPLIER: PLANT: SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 2 1 2 2 2 3 Duke Realty Services, LP Hanson 27 3500 psi 28 Days 5" maximum ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) DATE TESTED 5.0 10/31/2003 5.0 11/21/2003 5.0 11/21/2003 2 4 5.0 12/19/2003 Water added at site: 10 gallons CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA 4% 6% AIR CONTENT 5.3 UNIT WEIGHT (pct): NA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 56 MAXIMUM LOAD (lbs. force) 92310 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 Report No.: Project No.: Date of Service: Report Date: OVERALL PLACEMENT LOCATION: Paving 300' west, 150' north from southwest comer of building 197529 037333 10/24/2003 11/03/2003 MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/24/2003 WEATHER CONDFFIONS: Clear TIME SAMPLED: 9:05am BATCH TIME: 8:35am TEMPERATURE (F) -Am 65 F CONCRETE: 78 F TRUCK NO: 1015 TICKET NO: 76443 SAMPLE LOCATION: 80' north, 40' east from southwest comer of paving COMPRESSIVE STRENGTH (psi) FRACTURE TYPE 3260 Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 0 IDD Page 2 of 3 RoneEngineers Client: Duke Realty Services, LP Attn: Mr. Jeff Langston 5495 Belt Line Road, Suite 360 Dallas TX 75254 CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Hanson PLANT: 27 SPECIFICATION REQUIREMENTS STRENGTH: SLUMP (in): AIR TEST METHOD: CYLINDER MARKED SET NO. 3500 psi 28 Days 5" maximum ASTM C -172 ASTM C -31 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 ASTM C -39 MEASURED SLUMP (inches) 3 1 4.75 10/31/2003 3 2 4.75 3 3 4.75 3 4 4.75 Water added at site: 5 gallons Technician: Jeremy Watts Report Distribution: (1) Duke Realty Services, LP (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete DATE TESTED 11/21/2003 11/21/2003 12/19/2003 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630 -9745 CONCRETE COMPRESSIVE STRENGTH TEST PROJECT DATA REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) AGE (days) 7 28 28 56 Started: 6:45am Finished: 12:30pm (1) Pacheco Koch Consulting Engineers (1) Engineering Analyst (1) City of Coppell Bldg. Inspections MAXIMUM LOAD (Ibs. force) 99805 Report No.: Project No.: Date of Service: Report Date: Project: Freeport 10 500 Freeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. MIX DESIGN I.D.: 7752 PLACEMENT DATE: 10/24/2003 WEATHER CONDITIONS: Clear TIME SAMPLED: 10:25am BATCH TIME: 1 O:OOam TEMPERATURE (F) AIR 73 F CONCRETE: 84 F TRUCK NO: 32 TICKET NO: 76454 4% 6% AIR CONTENT 5.1 UNIT WEIGHT (pct): NA OVERALL PLACEMENT LOCATION: Paving 300' west, 150' north from southwest comer of building SAMPLE LOCATION: 80' north, 50' west from southeast corner of paving COMPRESSIVE STRENGTH (Psi) 197529 037333 10/24/2003 11/03/2003 FRACTURE TYPE 3530 Unbonded Cap K. Scott Watson, AET CMT Operations Manager Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01 DD Page 3 of 3