Loading...
Freeport NIP(7.0)-LR031209 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Duke Realty Services, LP Report No.: 199397 Attn: Mr. Jeff Langston ....Project No.: 037333 5495 Belt Line Road, Suite 360 ~ ~Date of Service: ! 1/10/2003 ~ ~ ?eport Date: 12/09/2003 project/'Fr port / Se~~es of ~esh concrete at the placement locations, pedorm requ~testmg, cast compressive strength s~ples ~d b~ng s~ples back to the laborato~ for curing ~d testing in accord~ce with applicable stand.ds. STRENGTH: SLUMP(iq: AIR(%): TEST METHOD: CONTRACTOR: Duke Realty Services, LP CONCRETE SUPPLIER: Hanson PLANT: 27 SPECIFICATION REQUIREMENTS 3500 psi @ 28 Days 5" maximum 4% -6% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 PROJECT DATA MIX DESIGN I.D.: 7752 PLACEMENTDATE: 11/10/2003 WEATHER CONDITIONS: Cloudy TIME SAMPLED: 8:50am BATCH TIME: 8; 15am TEMPERATURE (F) - AIR 49 F CONCRETE: 80 F TRUCK NO: 848 TICKET NO: 76853 AIR CONTENT (%): 5.2 UNIT WEIGHT (pcf): NA OVERALL PLACEMENT LOCATION: Sidewalk at northwest comer of project, sidewalk east and west of 2nd entry to parking lot north of building and sidewalk east and west of 3rd entry to parking lot north of building SAMPLE LOCATION: Sidewalk west of 2nd entry to parking lot north of building ASTM C-39 REPORT OF TE,qT,q Concrete Compressive Cylinder 6 12" (area 28.27 sq. in.) CYLINDER MEASURED IVIA XJUvIUIVI COMPRESSIVE MARKED SLU1VIP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (lbs. force) (psi) TYPE 1 1 5.0 11/17/2003 1 2 5.0 12/08/2003 1 3 5.0 12/08/2003 7 116055 4100 Unbonded Cap 28 139740 ~ Unbonded Cap 28 143800 ~ Unbonded Cap Average 5020 1 4 Technician: Jeremy Watts Report Distribution: (1) Duke Realty Services, LP (1) City of Coppell Engineering Dept. (1) Potter Concrete Hold Started: 7:30am Finished: 9:45am (1) Engineering Analyst (1) City of Coppell Bldg. Inspections K. Scott Watson, AET CMT Operations Manager (1) Pacbeco Koch Consulting Engineers / LIMITATIONS: The test results presented her~t~ere pt~ared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Roue Engineers, Ltd. 01DD Page 1 of 1