Loading...
Woodridge-LR 810619SOUTIIWESTEI N LABOR ,I'ORILS, INC. Dallas, Trx a,~ 6-19-81 File No. 27126-01 Report of tests on To Received from Soil Compaction L & N Land Corp. Attn: Mr. Stephen Crim Southwestern Contracting Co. Identification Marks Woodridge Additions III FIELD DENSITY TESTS: Subgrade-Natural Ground Date Rec'd. 6-17-81 - Field Moistu re Lo, at(on ( % ) 1. 9 + 00 South-5 + 50 west 29.9 2. 8 + 00 South-5 + 50 west 30.6 3. 7 + 00 South-5 + 50 west 19.0 4. 6 + 00 South-5 + 50. west 33.3 5. 5 + 00 South-5 + 50 west 15.1 Field Optimum Proctor Density Moisture Density Percent (Lbs./Cu. Ft.) (%) (Lbs./Cu. l:'t.) Density 90.8 21.3 95.8 94.8 * 89.7 21.3 95.8 93.6 * 107.4 16.1 108.0 99.4 84.7 21.3 95.8 88.4 * 120.1 9.2 123.0 97.6 Dark Brown Silty Clay Reddish Brown & Gray Sandy Clay Lt. Brown Silty Clay 95-.8#/cu. ft. at 21.3% optimum moisture 108.0#/cu. ft.. at 16.1% optimum moisture 123.0#/cu. ft. at 9.2% optimum moisture *Failed to meet required 95.0% compaction Technician: C. Mooney (2.0 hrs.) cc: 2-L & N Land Corp., Mr. Crim SOII'I'IIX~I.;Sl'EllN I,AII()IIAll)HI~;S, IN¢;. 1-Southwestern Contracting Co. ~~ 1-Lichliter Co. ~~ , Lah. No. D2412 / Page 3 of 3 SOUTH ff $TERN LABORATOry,,sS, INC. Dallas, Texas__ File No. Report of tests on To Received from Identification Marks Woodridge Addition, Phase III' · FIELD DENSITY TESTS: Date Rec'd. 6/19/81 Field Field .Optimum Proctor Moisture Density Moisture Density Percent (%) (Lbs./Cu. Ft.) (%) (Lbs./Cu. Ft.) Density '12. West Sta. 7+80, South Sta. 2+00, natural ground elev. 25 '13. West Sta. 7+50, South Sta. 3+00, natural ground elev. 17 14. West Sta. 6+50, South Sta. 4+80, 2nd lift 22 15. West Sta. 6+40, South Sta. 6+00, 2nd lift 22 16. West Sta. 6+10, South Sta. 7+00, 2nd lift 21 97 21.3 95.8 101 109 16.1 108 101 100 20.3 103.8 96 102 20.3 103.8 99 106 20.3 103.8 103 *Natural vegitation removed and compacted per job requirements. ~Ot II ~ · .... ,' "' 'k'll'.llN L.\IR)IJATORI 'S, IN(:. Lab. No. D3234 my Om }citers and reports are for the exclusive use of the chenl to whom they are addressed. The u~ of our name must receive out prior written appr,~al. Our let tc~s and reportx apply lo the ~mple tested and/or inspected, and ate not necessarily indicative of Ihe quali6es of appatently idenlical or simil~ p~oducts