Loading...
Kiddin' Around-LR000407Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 00.1014 CLIENT: Kiddin' Around, LLC DATE: 7 April 2000 PROJECT: Kiddin' Around Pla,/Care, Coppell, TX SUPPLIER: Nelson Bros. LOCATION OF POUR SET 1: Slab on grade, approx. 40'-50' west of east bldg. line, full width of slab LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 5 sks. Truck No. 223 Cement Ticket No. 83658 Flyash Time Batched 1:05pm Sand Time Sampled 1:30pm in. Concrete Temp. IASTM C1064) 76°F 1.0 in. Air Content [ASTM C231) Water Unit Weight IASTM C138l Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day (ASTM Cl 43~ psi Strength 17 6.50* 7 04/14~00 18 6.50 7 04/14~00 19 6.50 28 05~05~00 20 6.50 28 05/05/00 78,600 2780 80,000 2830 116,100 4110 119,500 4230 28-Day Average 4170 3OOO *Sampled before pumping, per superintendent. TECHNICIAN: DISTRIBUTION: MFM (1:00pm-2:30pm) (1) Kiddin' Around, LLC, Jeff Jones (1) Jerald W. Kunkel, Consulting Engineers (1) Mike Jones Masonry (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 00.1014 CLIENT: Kiddin' Around, LLC DATE: 7 April 2000 PROJECT: Kiddin' Around Pla,/ Care, Coppell, TX SUPPLIER: Nelson Bros. LOCATION OF POUR SET 1: Slab on grade, approx. 40'-50' west of east bldg. line, full width of slab LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. 5 sks. Truck No. 223 Cement Ticket No. 8365S F[yash Time Batched 1:05pm Sand Time Sampled 1:30pm in, Concrete Temp. (ASTM C1064) 76°F 1.0 in. Air Content IASTM C231) Water Unit Weight IASTM C13S) Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS IASTM C391 (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day {ASTM C1431 psi Strength 17 6.50' 7 04/14/00 18 6.50 7 04/14~00 19 6.50 28 05~05~00 20 6.50 28 05/05/00 78,600 2780 80,000 2830 28-Day Average 3000 *Sampled before pumping, per superintendent. TECHNICIAN: DISTRIBUTION: MFM (1:00pm-2:30pm) (1) Kiddin' Around, LLC, Jeff Jones (1) Jerald W. Kunkel, Consulting Engineers (1) Mike Jones Masonry (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148