Loading...
Kiddin' Around-LR000315Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN-PLACE DENSITY TESTS CLIENT: Kiddin' Around, LLC DATE: 15 March 2000 PROJECT: Kiddin' Around Play Care, Coppell, TX JOB NO.: 00.1014 MATERIAL DESCRIPTION: 1) On-Site Fill -Dark Grey Clay ASTM D 698 STANDARD PROCTOR: 11 96.0 pcf @ 22.0% Moisture MOISTURE DRY PERCENT REQUIRED LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION % PCF % °~ Building Pad 191 approx. 20' south of north bldg. line 1 4 25.2 96.3 100.3' 92-98 approx. 20' east of west bldg. line Min. +3% Over Optimum 201 approx. 10' north of south bldg. line 1 4 23.5' 98.3 102.4` approx. 30' east of west bldg. line 211 approx. 15' south of north bldg. line 1 4 23.1' 98.3 102.4` approx. 10' west of east bldg. line `Test results indicate fill is not compacted to required density/moisture. Contractor notified. TECHNICIAN: CDJ DISTRIBUTION: (11 Kiddin' Around, LLC, Jeff Jones 111 Jerald W. Kunkel, Consulting Engineers 111 Mike Jones Masonry 111 City of Coppell ~. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (2l4) 351-5148