Kiddin' Around-LR000315Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF IN-PLACE DENSITY TESTS
CLIENT: Kiddin' Around, LLC DATE: 15 March 2000
PROJECT: Kiddin' Around Play Care, Coppell, TX JOB NO.: 00.1014
MATERIAL DESCRIPTION: 1) On-Site Fill -Dark Grey Clay
ASTM D 698 STANDARD PROCTOR: 11 96.0 pcf @ 22.0% Moisture
MOISTURE DRY PERCENT REQUIRED
LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION
% PCF % °~
Building Pad
191 approx. 20' south of north bldg. line 1 4 25.2 96.3 100.3' 92-98
approx. 20' east of west bldg. line Min. +3%
Over Optimum
201 approx. 10' north of south bldg. line 1 4 23.5' 98.3 102.4`
approx. 30' east of west bldg. line
211 approx. 15' south of north bldg. line 1 4 23.1' 98.3 102.4`
approx. 10' west of east bldg. line
`Test results indicate fill is not compacted to required density/moisture. Contractor notified.
TECHNICIAN: CDJ
DISTRIBUTION: (11 Kiddin' Around, LLC, Jeff Jones
111 Jerald W. Kunkel, Consulting Engineers
111 Mike Jones Masonry
111 City of Coppell
~.
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (2l4) 351-5148