REPORT OF
IN -PLACE DENSITY
PROJECT: SMART START SCHOOL
NATCHES TRACE & DENTON TAP RD.
COPPELL
PAGE 1 OF 1
Maxim Technologies Inc.
2575 Lone Star Drive
Dallas, Texas 75212
Telephone: (214) 631 -2700
FAX: (214) 920 -1891
PROJECT NO.: 9908651
REPORT NO.: 149034
DATE OF SERVICE: 7/02/99
AUTHORIZATION: Mike
REPORT DATE: 7/10/99
SERVICES: Perform in -place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: WEBB CONSTRUCTION
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION:
DENSITY: 95 +%
MOISTURE: NA
PROJECT DATA
GAUGE: 3411B
GAUGE SERIAL NO.: 8927
STANDARD COUNTS
MOISTURE - CURRENT: 0560 PREVIOUS: 0564
DENSITY - CURRENT: 2240 PREVIOUS: 2242
TEST MODE: Direct Transmission
PROBE DEPTH (in.): 6
MOI TUREIDENSITY RELATIONS
ur MAXIMUM REFERENCE
TEST OF MATERIALS MOISTURE % DENSITY pc f REPORT NO
UTILITY FILL ERN &LIGHT BRN CLAY 18.5 106.5 148520
Dark Brown Clay 24.5 94.0 148251
TEST
NO LOCATION
1. WATERLINE 6" STATION 1 +20
6" BELOW SURFACE
2. WATERLINE 4 SIAMESE
CORRECTION SURFACE
3. WATERLINE AT HYDRANT 1'
BELOW SURFACE
REPORT OF TESTS
FIELD OPTIMUM FIELD DENSITY MAXIMUM
MOISTURE MOISTURE (Pef) DENSITY DENSITY
( %) (%) WET DRY (Pef) % max
19.0
16.8
18.1 18.5 124.4 105.3 106.5
41
Test results on this report meet project
specifications as noted above.
Technician: Burl Thomas Started: 01:OOPM Stopped: 02:30PM
ID
95
WI
Report Distribution:
1 Wry W ity W C ONS
MAXI EBB CONSTRUCTION T HNOLOGIES INC.
�1 C
1 Ci Coppell �5�
CME Divftion
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
full without the approval of the testin laboatory. The use of our name must receive our written appreval. Our letters and tts
1007 R, apply only to the sample tested and or manacled, antl are not indicative of the quantities of apparently identical or similar probum.
18.5 121.3 101.9 106.5
18.5 118.6 101.5 106.5
MA)aM
TECHNOLOGIES INC
CLIENT: WEBB CONSTRUCTION
5952 ROYAL LANE #110
ATTN: GARY WEBB
DALLAS, TX 75230
REPORT OF
IN -PLACE DENSITY
PROJECT: SMART START SCHOOL
NATCHES TRACE & DENTON TAP RD.
COPPELL
PAGE 1 OF 1
Maxim Technologies Inc.
2575 Lone Star Drive
Dallas, Texas 75212
Telephone: (214) 631 -2700
FAX: (214) 920 -1891
PROJECT NO.: 9902651
REPORT NO.: 14904
DATE OF SERVICE: 7/02/99
AUTHORIZATION: Mike
REPORT DATE: 7/:0/99
SERVICES: Perform in -place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: WEBB CONSTRUCTION
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION:
DENSITY: 95 +%
MOISTURE: NA
PROJECT DATA
GAUGE: 3411E
GAUGE SERIAL NO.: 8927
STANDARD COUNTS
MOISTURE - CURRENT: 0560 PREVIOUS: 0564
DENSITY - CURRENT: 2240 PREVIOUS: 2242
TEST MODE: Direct Transmission
PROBE DEPTH (fn.): 6
M I URE/DENSTTY RELATIONS
REFERENCE
TEST OF MATERIALS MOISTURE % DENSITY pc f REPORT NO
UTILITY FILL BRN &LIGHT BRN CLAY 18.5 106.5 148520
Dark Brown Clay 24.5 94.0 148251
TEST
NO LOCATION
1. WATERLINE 6" STATION 1 +20
6" BELOW SURFACE
2. WATERLINE 4" SIAMESE
CORRECTION SURFACE
REPORT OF TESTS
FIELD OPTIMUM
FIELD DENSITY
MAXIMUM
MOISTURE MOISTURE
(pcf)
DENSITY
DENSITY
( %) %
WET DRY
Pc
% max
19.0 18.5
121.3 101.9
106.5
96
16.8 18.5
118.6 101.5
106.5
95
3. WATERLINE AT HYDRANT 1'
BELOW SURFACE 18.1 18.5 124.4 105.3 106.5
Test results on this report meet project
specifications as noted above.
Technician: Burl Thomas Started: 01:OOPM Stopped: 02:30PM
M
Report Distribution:
� , ) WEBB C MAXIM TECHNOLOGIES INC.
1 city of coppau
, Ciy of Coppell
CME Division
Our afters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
full without the approval of the testin laboratory The use of our name must receive our written approyal. Our letters and repoM1s
1007 R. apply only to the sample tested and or inspected, and am not indicative of the quantities of apparentlyIdentical or similar products.
MAX&M
TECHNOLOGIES INC
CLIENT: WEBB CONSTRUCTION
5952 ROYAL LANE #110
ATTN: GARY WEBB
DALLAS, TX 75230
REPORT OF
IN -PLACE DENSITY
PROJECT: SMART START SCHOOL
NATCHES TRACE & DENTON TAP RD.
COPPELL
PAGE 1 OF 1
Maxim Technologies Inc.
2575 Lone Star Drive
Dallas, Texas 75212
Telephone: (214) 631 -2700
FAX: (214) 920 -1891
PROJECT NO.: 9908651
REPORT NO.: 149127
DATE OF SERVICE: 7/07/99
AUTHORIZATION:
REPORT DATE: 7/10/99
SERVICES: Perform in -place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: WEBB CONSTRUCTION
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION:
DENSITY: 95%
MOISTURE: NA
PROJECT DATA
GAUGE:TROXLER 3430
GAUGE SERIAL NO.: 27660
STANDARD COUNTS
MOISTURE - CURRENT: 642 PREVIOUS: 639
DENSITY - CURRENT: 2860 PREVIOUS: 2869
TEST MODE: Direct Transmission
PROBE DEPTH (In.l: 8
M I TURE/DENSnY RELATONS REFERENCE
TEST OF MATERIALS MOISTURE % DENSnY oaf REPORT NO
PAVING SUBGRADE BRN &LIGHT BRN CLAY 18.5 106.5 148520
REPORT OF TESTS
2. EAST FIRELANE CENTER,60'
NORTH OF SOUTH END 16.1 18.5 119.1 102.6 106.5 96
3. EAST FIRELANE CENTER,25'
NORTH OF SOUTH END 16.9 18.5 118.4 101.3 106.5 95
Test results on this report meet project
specifications as noted above.
Technician: Jay Canafax, CET Started: 02:30PM Stopped: 05:00PM
Report Distribution:
(1
City of CONS RUCTION
I 11 MAXIM XECHNOLOGIES INC.
city of Cop
1 pal
CME Di ision
Our letters and reports are for the exclusive use of the client to wTom they are addressed and shall not Ee reproduced except in
lull without the approval of the testipi laboratory , The use of our name must receive our written approval. Our letters and reports
1007 R. apply only to the sample tested an d�or inspected, and are not indicative of the quantities of apparently Identical or similar products.
FIELD
OPTIMUM
FIELD DENSITY
MAXIMUM
TEST
MOISTURE
MOISTURE
(Pcf)
DENSITY
DENSITY
NO LOCATION
I %)
( %)
WET DRY
(Pcf)
% max
1. EAST FIRELANE CENTER, 100'
NORTH OF SOUTH END
16.4
18.5
121.5 104.4
106.5
98
2. EAST FIRELANE CENTER,60'
NORTH OF SOUTH END 16.1 18.5 119.1 102.6 106.5 96
3. EAST FIRELANE CENTER,25'
NORTH OF SOUTH END 16.9 18.5 118.4 101.3 106.5 95
Test results on this report meet project
specifications as noted above.
Technician: Jay Canafax, CET Started: 02:30PM Stopped: 05:00PM
Report Distribution:
(1
City of CONS RUCTION
I 11 MAXIM XECHNOLOGIES INC.
city of Cop
1 pal
CME Di ision
Our letters and reports are for the exclusive use of the client to wTom they are addressed and shall not Ee reproduced except in
lull without the approval of the testipi laboratory , The use of our name must receive our written approval. Our letters and reports
1007 R. apply only to the sample tested an d�or inspected, and are not indicative of the quantities of apparently Identical or similar products.
MA)CkM
TECHNOLOGIES INC
CLIENT: WEBB CONSTRUCTION
5952 ROYAL LANE #110
ATTN: GARY WEBB
DALLAS, TX 75230
PROJECT: SMART START SCHOOL
NATCHES TRACE & DENTON TAP RD.
COPPELL
REPORT OF
IN -PLACE DENSITY
23.5
SERVICES: Perform in -place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR:
METHOD OF TE
DENSITY:
MOISTURE:
SPECIFICATION
DENSITY:
MOISTURE:
WEBB CONSTRUCTION
3T:
ASTM D2922
ASTM D3017
95&
+3%
PROJECT DATA
GAUGE: TROXLER 3411 -B
GAUGE SERIAL NO.: 12834
STANDARD COUNTS
MOISTURE - CURRENT: 565 PREVIOUS: 545
DENSITY - CURRENT: 2740 PREVIOUS: 2715
TEST MODE: Direct Transmission
PROBE DEPTH (in.): 6
MOISTURE /DENSITY. RELATIONS
REFERENCE MAAiMUM TEST OF MATERIALS MOISTURE % DENSITY ccf REPORT NO
ON -SITE Dark Brown Clay 24.5 94.0 148251
ON -SITE ERN &LIGHT BRN CLAY 18.5 106.5 148520
TEST
NO LOCATION
1. SOUTH END OF BUILDING PAD
FINAL GRADE
2. NORTH END OF BUILDING PAD
FINAL GRADE
3. FIRE LANE AT 30' WEST OF AND 4
0' NORTH, OF NORTHWEST -
13UILDING CORNER FINAL GRADE
4. FIRE LANE AT 20' NORTH OF
NORTHWEST BUILDING CORNER
FINAL GRADE
18.6
PAGE 1 OF 2
Maxim Technologies Inc.
2575 Lone Star Drive
Dallas, Texas 75222
Telephone: (214) 631 -2700
FAX: (214) 920 -1891
PROJECT NO.: 9908651
REPORT NO.: 148516
DATE OF SERVICE: 6/17/99
AUTHORIZATION: David Ortiz
REPORT DATE: 7/10/99
24.5 114.5 92.5 94.0 98
24.5 117.6 95.2 94.0
18.5 126.1 106.3 106.5
14.8 * 18.5 119.7 104.3 106.5
Report Of Tests Continued On Page 2
REPORT OF TESTS
FIELD OPTIMUM FIELD DENSITY MAXIMUM
MOISTURE MOISTURE (Pcfl DENSITY DENSITY
( %) I %) WET DRY (Pcf) I% max)
23.8
101
100
98
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
full without the approval of the testing laboratory. The use of Our name must receive our written approval. Our ratters aM reports
1007 R. apply only to the sample tested and /or Inspected, and are not Indicative of the quantities of apparently Identical or similar products.
WEBB CONSTRUCTION
PROJECT N0. 9908651
DATE OF SERVICE: 6/17/99
REPORT OF TESTS (continued)
REPORT NO. 148516
PAGE 2 OF 2
An asterisk ( *) appears next to test results which
do NOT meet the project specifications as noted on page 1
4
Technician: Randy Wentzler, C.E.T. Started: 01:OOPM Stopped: 04:OOPM
Report Distribution:
11) WE6OC CT10N
City of MAXIM TECHNOLOGIES INC.
It 1
Itl City of COppell \ ^\
\ 1
ME Division
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
full without the approval of the testing laboratory. The use of our name must receive our written ap rpval. Our letters anE reports
100] R. apply only to the sample tested and /or inspected, and are not indicative of the quantities 0 f all arentPy identical or similar prpducts.
FIELD
OPTIMUM
FIELD DENSITY
MAXIMUM
TEST
MOISTURE
MOISTURE
(pcf)
DENSITY
DENSITY
NO
LOCATION
I%)
(95)
WET DRY
(Pcf)
I% max)
5.
FIRE LANE AT 40' NORTH OF AND
40' EAST OF NORTHEAST
BUILDING CORNER FINAL GRADE
16.5
18.5
118.9 102.1
106.5
96
6.
18' RCP STORM DRAIN AT STATION
0 +20 FINAL GRADE
24.5
24.5
114.2 91.7
94.0
98
An asterisk ( *) appears next to test results which
do NOT meet the project specifications as noted on page 1
4
Technician: Randy Wentzler, C.E.T. Started: 01:OOPM Stopped: 04:OOPM
Report Distribution:
11) WE6OC CT10N
City of MAXIM TECHNOLOGIES INC.
It 1
Itl City of COppell \ ^\
\ 1
ME Division
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
full without the approval of the testing laboratory. The use of our name must receive our written ap rpval. Our letters anE reports
100] R. apply only to the sample tested and /or inspected, and are not indicative of the quantities 0 f all arentPy identical or similar prpducts.