Smart Start-LR 990629MAX&M
TECHNOLOGIES INC
CLIENT: WEBB CONSTRUCTION
5952 ROYAL LANE #110
ATTN: GARY WEBB
DALLAS, TX 75230
REPORT OF
IN -PLACE DENSITY
PROJECT: SMART START SCHOOL
NATCHES TRACE & DENTON TAP RD.
COPPELL
PAGE 1 OF 1
Maxim Technologies Inc.
2575 Lone Star Drive
Dallas, Texas 75222
Telephone: 1214) 631 -2700
FAX: 1214)920 -1891
PROJECT NO.: 9908651
REPORT NO.: 148733
DATE OF SERVICE: 6/24/99
AUTHORIZATION: Mike w /Battson
REPORT DATE: 6/29/99
SERVICES: Perform in -place density and moisture content tests to determine the degree
of field compaction.
TEST
NO LOCATION
1. 6" Sanitary Sewer, Sta. 1 +70
1' below surface
2. 8" Sanitary Sewer, Sta. 0 +80
2.5' below surface
REPORT OF TESTS
PROJECT DATA
CONTRACTOR: WEBB CONSTRUCTION
GAUGE: Troxler 3411 -B
OPTIMUM
FIELD DENSITY
METHOD OF TEST:
GAUGE SERIAL NO.:
MOISTURE
MOISTURE
DENSITY: ASTM D2922
STANDARD COUNTS
DENSITY
(%)
MOISTURE: ASTM D3017
MOISTURE - CURRENT: 561
PREVIOUS:
563
SPECIFICATION:
DENSITY -CURRENT; 2252
PREVIOUS:
2245
18.5
TEST MODE: Direct Transmission
106.5
96
DENSITY: Dry density 95%
PROBE DEPTH (in.): 6
119.5 102.5
106.5
MOISTURE: N/A
MOISTURE /DENSITY
RELATIONS
TEST OF
MATERIALS MOISTURE %
lVAAiMUM
DENSITY Dcf
REFERENCE
REPORT NO
Utility Fill BRN &LIGHT BRN CLAY 18.5
Utility
106.5
148520
Fill Dark
Brown Clay 24.5
94.0
148251
TEST
NO LOCATION
1. 6" Sanitary Sewer, Sta. 1 +70
1' below surface
2. 8" Sanitary Sewer, Sta. 0 +80
2.5' below surface
REPORT OF TESTS
FIELD
OPTIMUM
FIELD DENSITY
MAXIMUM
MOISTURE
MOISTURE
Ipcf)
DENSITY
DENSITY
(%)
( %)
WET DRY
(Pcf)
(% max)
18.7
18.5
121.1 102.0
106.5
96
16.6
18.5
119.5 102.5
106.5
96
3. 8" Sanitary Sewer, Sta. 1 +40
2.5' below surface 17.9 18.5 123.1 104.4 106.5
Test results on this report meet project
specifications as noted above.
Technician: Burl Thomas Started: 06:OOAM Stopped: 09:30AM
98
Report Distribution:
Ill WE9aC 1CTlON MAXIM TECHNOLOGIES INC.
111 City of Copped
111 City of Cpppell
L C Division
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced except in
100] TC full without the approval of the testing laboratory. The use of our name must receive our written app,oval. Our letters antl reports
apply only to the sample tested and /or inspected, and are not indicative of the quantities of apparently identical or similar products.