Loading...
Riverchase (6.2)-LR 971125CONCRETE COMPRESSIVE STRENGTH TEST ]~ ENGQdF.F.RING, WC. 4747 Irving Blvd., Suite 8206 Dallas, Texas 75247 Date of Service: 1 1 /14/1997 Report No.: 9724689 Report Date 11/25/1997 Client No.: 17192300 Project No.: 43-1803-97 Client: Dallas Car Wash, Ltd. Attn: Grey Stogner 6780 Abrams Road, Suite 207 Dallas TX 75231 Project: Grand Car Wash Riverchase and MacArthur Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required field test and cast compressive strength samples.** PROJECT DATA CONTRACTOR: Spitng Valley CDn9trBCtID17 CONCRETE SUPPLIER: PlOneer CODCrete PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 2500 psl @ 28 Days SLUMP: 4° AIR: N/A TEST n4ETHOD: ASTM C-143 ASTM C-172 ASTM C-39 SAMPLE LOCATION: Same CONCRETE CLASS: 9114 PLACEMENT DATE: 11/14/1997 BATCH TIME: 9:53 am TIME SAMPLED: 10:30 am BY: Roy Montgomery WEATHER CONDITIONS: CIOUdy TEMPERATURE (F)-AIR 46 F CONCRETE: 74 F TRUCK NO: 4O2 TICKET NO: S 74093 AIR CONTENT (%): N/A UNIT WEIGHT (pct): NIA PLACEMENT LOCATION: Paving, northeast comer [o Building B at paves[one area REPORT OF TESTS ACCUMULATIVE YARDS: 14 CYLINDER MEASURED MAXIMUM COMPRESSIVE MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE SET NO. (inches) TESTED (days) (Ibs. force) (psi) TYPE I 1 4.00 11/21/1997 7 91830 3250 I 2 4.00 11/21/1997 7 89730 3170 Average 3210 I 3 4.00 12/12/1997 28 I 4 4.00 12/12/1997 28 Technician: Roy Montgomery Started: 9:30 am Finished: 11:30 ~ Engi ring, Inc. Report Distribution: (1) Dallas Car Wash, Ltd. (I) City ofCoppcll (I) Winkelmann & Associates, Ina Eugene Harbour (I) ROP/DW Architects Vice President (I) Spring Valley Construction "this report is exclusively for the use of the client indicated above and shall not be reproduced except in full without [he written approval of HBC Engineering, Inc. O LxK Page 1 of I