Loading...
Riverchase (6.2)-LR 971001IN-PLACE DENSITY TESTING ENCINEERWG, INC. 4747Irving Blvd., Suite #206 Dallas, Tezas 75247 Date of Service: 09/26/1997 Report No.: 9720900 Report Date 10/01/1997 Client No.: 17192300 Project No.: 43-1803-97 Client: Dallas Car Wash, Ltd. Project: (}rand Car Wash Attn: Grey Stogner Riverchase and MacArthur 6780 Abrams Road, Suite 207 Dallas TX 75231 Coppell, Texas Services: In-place density testing. PROJECT DATA coNTRa,croR: Spring Valley Construction Laboratory Tat Method: ASTM D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: M/D No. Description 1 TEST NO 69 70 71 72 73 Med brn sandy clay (]t) Maximum Project Requirements Moisture% Density pcf Moisture Density 23.5 96.5 -1/+3% 95% FIELD DENSITY TESTS TEST LOCATION South Drive Subgrade, SE comer of main bldg, 25'S + 30'E Subgrade, SE comer of main bldg, 25'S + 110'E Su'ngrade, SEC of main bldg, 200'E of W end, CL East Drive Subgrade, 20'N of S end, right of centerline Subgrade, 80'N of S end, left of centerline M/D MOISTURE DRY DENSITY DENSITY No. (%) (pct) (% max) 1 23.7 96.1 100 I 23.8 95.9 99 1 23.9 96.0 100 1 24.0 96.3 100 1 23.7 96.0 100 Test results on this report meet project specificatioD. Technician: Tex King Report Distribution: ([) Dallas Car Wash, Ltd. (I) City of Coppell (I) Winkelmann & Associates, Inc. (l) ROF/DW Architects (1) Spring Valley Construction En ' ing, Inc. Paul D. Smith, P.E. Senior Project Engineer This report is exclusively for [he use of the client indicated above and shall not be reproduced except in (ull without the written approval of HBC Engineering, Inc. U7MP Page 1 of 1 IN-PLACE DENSITY TESTING ]~ ENCINEQ2A]G, INC. 4747 Irving Blvd., Suite #206 Dallas, Texas 75247 Date of Service: 09/23/1997 Report No.: 9720556 Report Date 10/01/1997 Client No.: 17192300 Project No.: 43-1803-97 Client: Dallas Car Wash, Ltd. Project: Grand Car Wash Attn: Grey Stogner Riverchase and MacArthur 6780 Abrams Road, Suite 207 Dallas TX 75231 Coppell, Texas Services: In-place density testing. PROJECT DATA CONTRACTOR: Spring Valley CDnstructlon Laboratory Test Method: ASTM D-698 Field Test Method: ASTM D-2922 ASTM D-3017 MOISTURE DENSITY RELATIONS: Maximum Project Requirements M/D No. Description Moisture % Density pcf Moisture Density 1 Med brown sandy clay (lt) 23.5 96.5 -1/+3°/a 95% FIELD DENSITY TESTS TEST M/D MOISTURE DRY DENSITY DENSITY NO TEST LOCATION No. (%) (pcQ (% max) 65 Subgrade, firelane on W side, 50'S of N end, CL 1 24.1 94.3 98 66 Subgrade, N drive, 60'E of W end, R of centerline 1 23.9 94.5 98 67 Subgrade, N drive, 170'E of PJ end, L of centerline 1 23.8 94.2 98 68 Subgrade, W drive, 55'S of N end, centerline 1 24.0 94.2 98 Test results on this report meet project specification. Technician: Tex King ~ Engiy e i ,Inc. Report Distribution: (I) Dallaz Car Wash, Ltd. (I) City of Coppell (I) Winkelmann &Associates, Inc. PaUI D. Smith, P.E. (I) ROF/DW ArchitecU Senior Project Engineer (1) Spring Valley Construction This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of HBC Engineering, Inc. 07MP Page 1 of 1