Loading...
ST9302-LR020107ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 Tested For: CITY OF COPPELL ATTN: KEN GRIFFIN 255 pARKVVAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Oesc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS Concrete Compression Test Report Our Report No.: 98881-229 Issue Date: 01107/2002 RELD DA TA Placement Location: SEE NOTES Date Placed: 12/21101 Time Placed: 9:40 AM Slump (ASTM C-143): 5.0 Air Content: 4.8 (ASTM C-173) Air Temperature: 44 Specimen Temperature: 68 Date Received: 12/22/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORSYTHE, GREG Mix Data Submitted By: LMC Plant Number: 7-3000 Delivery Ticket No.: 7112040 Made By: ALPHA Cured Specification: ASTM C-31 CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg F.~;.~' Area: Max No.: l~'Jpe: $~r~.~ Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 338 LAB C-1231 12/28/01 7 12 N/A 6 28.27 83150 2940 339 LAB 1/18/02 28 12 N/A 6 28.27 0 340 LAB 1118/02 28 12 N/A 8 28.27 0 341 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 N/A Results to Date: Notes: SIDEWALK, 10'N & 5'E FROM THE LIGHT POLE AT THE NW CORNER OF SANDY LAKE RD. & MOORE CC: CITY OF COPPELL, ED SELL CONSTRUCTION Respectfully Submitted By: · //~/ of Alpha Testing, Inc.