Old Townhomes-CS031120 (2)eresa Turners- Old Coppell_ _~T°wnh°mes_ _ Page 1;
From:
To:
Date:
Subject:
Teresa Turner
ipool@c-pengineering.com
11/20/03 4:06:12 PM
Old Coppell Townhomes
Jason:
Here's is what I've found out so far .......
If you want to tie into the S.S. manhole in the Hunterwood Park as we discussed, you would have to
upsize the next section of 6" line to an 8" line. The 6" line was not designed to accommodate any
additional flow.
It would be preferable to rebuild the S.S. line in Coppell Road. The City would consider discussing the
possibility of entering into a Developer's Agreement to offset at least part of the cost.
As far as drainage is concerned - we would require you to extend a pipe from your property to at least the
limits of the floodplain. The Coppell Road Business Park plans were approved in 1987 which was prior to
our current Subdivision Ordinance. We do not allow open drainageways along property lines.
It is possible that you could coordinate with the property owner to the south to provide an access structure
to the stormwater system for future development. He may be willing to share in a part of the expense to
build the line. I can provide you with contact information if this is something you wish to pursue.
I was unable to obtain a legal description of the Var. Utility Easement. It would still be helpful if you could
provide that.
Please let me know if I can provide and additional information.
Teresa Turner
City of Coppell
Engineering Depadment
972-304-3681