Loading...
ST9302-SP 981008 (2)FAX (214) 352-3201 TELEPHONE (214) 358-6581 ED BELL CONSTRUCTION COMPANY POST OFFICE BOX 540757 10605 HARRY HINES DALLAS. TEXAS 7S354-6757 DALLAS, TEZA,, ,S 75220 TO: Kimley-Hom and Associates, Inc. 801 Cherry Street, Sui.t¢ 1100 Fort Worth, Texas 76102 LETTER OF TRANSMITTAL Date: October 8, 1998 I Job#: 939 Attn: Michael G. DeMotte Re: Sandy Lake Road Reconst~mction City of Coppell, Texas THE FOLLOWING ITEMS ARE ATTACHED: Copies Spec Section Submittal No. Description 6 NCTCOG 7 4" through 12" PVC Water Pipe Item 2.12.20 THESE ARE BEING TRANSMITTED: Information for Record O&M Data 'r- Ir~formation for Engineer's Approval '~ Remm 2 Copies CERTIFICATION: Tkis information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders, and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS/REMARKS: Robert D. Weber Project Engineer .AN EQUAL OPPORTUNITM EMPLOYER For use in municipal water systems, firelines and other critical services. Strength Class 100, 150 and 200 Blue Brute water pipes have long-term hydrostatic strength that meet the commonly accepted high safety requirements of municipal water systems. Blue Brute conforms to cast iron O.D.'s and is available in 4", 6", 8", 10" and 12" sizes in Class 100, 150, and 200. Meets AWWA C900 Underwriters Laboratories and NSF 61 Listed, Factory Mutual Approved. J-M Manufacturing's Blue Brute Class 150 and 200 PVC water pipes are listed for critical use in firelines and water mains and are F/M approved. Blue Brute Class 100 is intended for water mains. Light weight A 20 foot length of Class 150, 8" Blue Brute water pipe weighs approximately 181 pounds. That makes it easy to load, easy to transport and easy to handle. Installers prefer it because it goes into the ground quickly -- thus saving on installation costs. Long laying lengths A standard laying length of Blue Brute PVC water pipe is 20 feet. That means you can cover a lot of ground during installation. At the same time, you eliminate the cost of unnecessary joints. Corrosion resistance Blue Brute is unaffected by electrolytic or galvanic corrosion, or any known soil or water condition. You don't have to worry about tuberculation, or the need for costly lining, wrapping, coating or cathodic protection. Quality control Without exception, each length of pipe is hydrostatically tested and subject to inspection by our quality control inspectors throughout every step of the manufacturing process. Flow capacity This PVC water pipe has a smooth interior that stays smooth over long years of service with no loss in carrying capacity. Its coefficient of flow is C = 150 (H&W) -- the best available in common use in water systems. This capacity often allows savings in pumping costs as well as savings on the size of pipe required. Field cutting You can cut Blue Brute with a powersaw or an ordinary handsaw. It eliminates the need to invest in costly cutting equipment. Service life Because it is nonmetallic, the pipe does not lose strength due to either potable water corrosion or external galvanic or soil corrosion. And its design includes a surge allowance for a 2 ft./sec, stoppage of flow. Ring-Tite joints with factory installed rings Blue Brute's Ring-Tite joint can be assembled quickly. Seated in a deep groove, the flexible elastomeric ring provides a tight seal that protects the line from shock, vibration, earth move- ment and compensates for expansion and contraction of pipe lengths. And there's no field mixing or application of cement, it's a simple push-together joint that remains tight under normal operating conditions. Ring-Tite joint with factor~ installed rin~l factory installed Spigot pipe rubber sealing ends are ring provides supplied tight, flexible from factory seal with bevels. ~ bell is an integral part of the pipe length with the same strength. Installation Product should be installed in accordance with J-M Publication TR-704B, "Blue Brute® PVC Class Water Pipe, Installation Guide." Short form specification Accessories Blue Brute is backed up by all the items it takes for smooth installation of water pipe. Direct taps can be made with proper tapping tools. (See detailed instructions on tapping in the "Blue Brute Installation Guide", TR-704B.) Pipe stiffness The pipe stiffness using F/Ay for PVC class water pipe is contained in the table Scope This specification designates general requirements for unplasticized polyvinyl chloride (PVC) plastic class water pipe below: with integral bell and spigot joints for Class DR F/Ay (psi) the conveyance of water and other fluids. 100 ~ 129 d150 16 364 Materials 200 -- '14 815 Pipe shall meet the requirements of AWWA C900, "Polyvinyl Chloride (PVC) Quick burst test Water Distribution". All Class 100 pipe shall Randomly selected samples tested in meet the requirements of DR 25, Class 150 pipe shall meet the requirements of DR 18 and Class 200 the requirements of DR 14. Pipe All pipe shall be suitable for use as pressure conduit. Provisions must be made for expansion and contraction at each joint with an elastomeric ring. The bell shall consist of an integral wall section with a factory installed, solid cross section elastomeric ring which meets the requirements of ASTM F-477. The bell section shall be designed to be at least as hydrostatically strong as the pipe wall and meet the requirements of AWWA C900. Sizes and dimensions shall be as shown in this specification. Joint design meets qualification requirements of ASTM F3139. Hydro Testing Each pipe shall be tested to four times the pressure class of the pipe for a minimum of 5 seconds. The integral bell shall be tested with the pipe. Standard Laying Lengths Standard laying lengths shall be 20 feet (----_ 1 ") for all sizes. accordance with ASTM D 1599 shall withstand, withoutfailure, pressures listed below when applied in 60-70 seconds. Minimum burst Class pressure at 73°F (psi) 100 555 ~- 200 985 Drop impact test Pipe shall withstand, without failure at 73"F, an impact of a falling missile, Tup C, at the following levels. (Per ASTM D 2444). Pipe Impact size(in.} (ft./lbs.) 4 100 6 100 8 100 10 120 12 120 There shall be no visible evidence of shattering or splitting when the energy is imposed. Cast iron O.D. Available in 4", 6", 8", 10" and 12" sizes, this pipe can be connected directly into cast and ductile iron fittings without adaptors or complicated procedures. 5 Flow characteristics and dimensions Flow chad Class 1OO (DR 25) Velocity Head loss Velocity Head loss Velocity Head loss Velocity Head loss Velocity Head Ios~ ft./sec, psi/lO0' ft./sec, psi/100' ft./sec, psi/lO0' ffJsec, psi/100' ft./sec, psi/lOO' Gals./ Pipe size (in.) min. 4 4.39 I.D. 6 6,30 I.D. 8 8.28 I.D. 10 10.16 I.D. 12 12.08 I.D. 100 2.12 0.16 200 4.24 0.57 2.05 0.10 300 6.35 1.21 3.O7 0.21 400 8.47 2.07 4.10 0.35 2.38 0.09 500 5.12 0.53 2.98 0.14 600 6.15 0.75 3.57 0.20 700 7.17 0.99 4.17 0.27 800 8.20 1.27 4.76 0.34 900 9.22 1.58 5.36 O.42 1,000 5.96 0.51 1,500 8.93 1.09 2,000 2,500 3,000 3,500 2.38 0.07 2.77 0.10 3.17 0.13 2.24 0.05 3.56 O.16 2.52 0.07 3.96 0.19 2.80 0.08 5.94 0.40 4.20 0.17 7.92 0.69 5.60 0.29 9.90 1.04 7.00 0.45 8.40 0.62 9.80 0.83 Class 150 (DR 18) Gals./ Pipe size (in.) min. 4 4.23 I.D. 6 6.09 I.D. 8 7.98 I.D. 10 9.79 I.D. 12 11.65 I.D. 100 2.28 0.19 200 4.57 0.69 2.20 0.12 300 6.85 1.46 3.30 0.25 400 9.13 2.48 4.41 0.42 2.57 O.11 500 5.51 0.64 3.21 0.17 2.13 0.06 600 6.61 0.69 3.85 0.24 2.56 0.09 700 7.71 1.18 4.49 0.32 2.98 0.12 2.11 0.05 800 8.81 1.52 5.13 0.41 3.41 0.15 2.41 0.06 900 9.91 1.89 5.77 0.51 3.84 0.19 2.71 0.08 1,000 6.41 0.61 4.26 0.23 3.O1 0.10 1,500 9.62 1.30 6.39 0.48 4.51 0.21 2,000 8.52 0.82 6.02 0.35 7.52 0.53 2,500 9.03 0.74 3,000 Class 200 (DR 14) Gals./ Pipe Size (in.) Min. 4 4.07 LD. 6 5.86 I.D. 8 7.68 I.D. 10 9.42 I.D. 12 11.20 I.D. 100 2.47 0.23 200 4.93 0.83 2.38 O.14 300 7.40 1.76 3.57 0.30 2.08 0.08 400 9.66 2.99 4.76 0.51 2.77 0.14 500 5.95 0.77 3.46 0.21 2.30 0.08 600 7.14 1.O7 4.16 0.29 2.76 0.11 700 8.33 1.43 4.85 0.38 3.22 0.14 2.28 0.06 800 9.52 1.83 5.54 0.49 3.68 0.18 2.60 0.08 1,000 6.93 0.74 4.60 0.28 3.26 0.12 1,2OO 5.53 0.39 3.91 0.17 1,400 6.45 0.52 4.56 0.22 1,600 7.37 0.67 5.21 0.29 2,000 9.21 1.01 6.51 0.43 2,500 8.14 0.66 3,000 9.77 0.92 Coefficient of flow is C = 150 (Hazen and Williams) 3 Velocity and head loss data are based on nominal inside diameter which sou s de d ama er minus twice Imckness · nora ) Dimensions (average) Class 100 (DR 25)* Pipe Outside Nom. inside T (min.) E Approx· Wt. size (in.) dia. (in.) dia. (in.)** thick. (in.) dim. (in.) De Ibs·/ft. 4 4.80 4.39 .192 4.75 6.4 1.9 6 6.90 6.30 .276 5.50 8.8 3.9 8 9.05 8.28 .362 6.25 11.4 6.7 10 11.10 10.16 .444 7.00 13.8 10.1 12 13.20 12.08 .528 7.80 15.9 14.4 Class 150 (DR 18)* 4 4.80 4.23 .267 4.75 6.5 2.6 6 6.90 6.09 .383 5.50 9.0 5.3 8 9.05 7.98 .503 6.25 11.6 9.2 10 11.10 9.79 .617 7.00 14.1 13.9 12 13.20 11.65 .733 7.80 16.7 19.7 Class 200 (DR 14)* 4 4.80 4.07 .343 4.75 6.8 3.2 6 6.90 5.86 .493 5.50 9.4 6.7 8 9.05 7.68 .646 6.25 12.1 11.6 10 11.10 9.42 .793 7,00 14.3 17.6 12 13.20 I 1.20 .943 7.80 16.9 25.1 · DR (D~mension Ratlol ~s the outside diameter divided by the minimum wall thickness T ( min. I **Nominal inside diameter equals the outside disn~eter minus twice thickness T (nom.) 89 4 The physical (or chemical) properties of J-M products described herein represent typical average values ob- tained in accordance with accepted test methods and are subject to normal manu- facturing variations. They are supplied as a technical service and are subject to change without notice. WARRANTY J-M warrants that its standard products are manufactured in accordance with its applicable material specifications and are free from defects in workmanship and materials, using J-M's specifications as a standard. Every claim under this warranty shall be deemed waived unless in writing and received by J-M within thirty (30) days of the date the defect was discovered, and within one (1) year of the date of the shipment. Claims for product appearance defects, such as sunbleached pipe etc., however, must be made within thirty (30) days of the date of the shipment. J-M must first be given an opportunity to inspect the product alleged to be defective in order to determine if it meets J-M specifications and if the handling, installation, and operating conditions have been satisfactory and in accor- dance with J-M recommended practices. Products sold by J-M which are manufactured by others are warranted only to the extent and limits of the warranty of the manufac- turer. The limited and exclusive remedy for breach of the above warranty by J-M shall be the resupply of a like quart- tity of non-defective product. J-M shall not be liable for any INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES OF ANY KIND, INCLUDING, WITHOUT LIMITATION, ANY EXPENSES FOR REMOVAL OR REINSTALLATION RESULTING FROM ANY DEFECT. J-M MAKES NO OTHER REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR iMPLiED, IN FACT OR IN LAW, INCLUDING, WITHOUT LIMITATION, THE WARRANTY OF MERCHAN- TABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, OTHER THAN THE LIMITED WARRANTY SET FORTH HEREIN. Visit our website at www.jmpipe.com J-M SALES & MARKETING / J-M PIPE CUSTOMER SERVICE CENTER 201/535-1633 OR 800/621-4404 J-M PIPE J-M Manufacturing Company, Inc. ~ P~ch Tree Hill TRX-27 REV 3/97 B O nc Made ,n USA