ST9302-SP 990823TO: Kimley-Hom and Associates, Inc. 801 Cherry Street~ Suite 1 t00 Fort Worth, Texas 76102 LETTER OF TRANSMITTAL Date: August 23, 1999 I Job #: 939 Attn: Michael G. DeMotte Re: Sandy Lake Road Reconstruction City of Coppell, Texas THE FOLLOWING ITEMS ARE ATTACHED: Copies Spec Section Submittal No. Description 6 NCTCOG 16 Concrete batch designs for 3000 psi (5 sack) Standard and 3600 psi (6 sack) concrete. EBCC will Specification produce this concrete with our batch plant. Item 7.4 Intended for utilization on sidewalk, paver base, driveways, and street paving (slip & i hand work). THESE ARE BEING TRANSMITTED: Infom~ation for Record __ O&M Data '~ Information for Engineer's Approval Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders, and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS/REMARKS: 1999 Signcd: Robert D. Weber Project Engineer T~CHMOLOGIE5 IN¢ Maxim Technologies Inc. 2.~75 L~ne ~ Dr.' D~I~, Texas 7~.~22 Te~eDhone:. (214) 631-2700 F~C~: (214) g20-~1 Client: Project: Portland Cement Concrete Mix Design Report Ed Bell Construction 10605 Harry Hines Blvd. Dallas, Texas 75220 Arm: Jay Simms Concrete Mix Design Sandy Lake Road Project No.: 9863997 Report No.: 149416 Service Date: 7/17/99 Page 1 of I Identification: 5 sack slip form mix Requirements Design Specification Compressive Strength (psi ,/days) 3000 psi NA Cement Content (sack) 5.0 N/A Slump (inches) 3.0 max NA Water Cementitious Ratio (lbs/lbs) 0.5 l NA Entrained Air Content (%) 5.0% NA I Materials ', Source iCement Fly Ash Coarse Aggregate Fine Aggregate Admixture #I WR Grace I[Admixture #2 WR Grace Holman Cement Co. N/A 1 I/2" Lattimore Marock Water Reducer Air Entrainment Size or Type Type 1/II N/A Crushed Stone Natural Sand ASTM C494 ASTM C260 Specific Gravity, 3.15 N/A 2.67 2.62 NA NA Proportions Weight Absolute Volume One Cubic Yard SSD Basis (lbs) (cubic Feet} Cement Fly Ash Coarse Aggregate Fine Aggregate Water Admixture #1 Water Reducer ASTM C494 Admixture #2 Entrained Air ASTM C260 Totals 47O N/A 1925 1285 24O 14.1 oz 3.0 oz 3920 2.39 N/A 11.55 7.86 3.85 NA 1.35 27.00 Unit Weight of Fresh Concrete(lb/cubic foot): 145.2 Adjust water to maintain 3" slump. Adjust air entraining agent to maintain 5.0% air content. Weights are S.S.D.- Moisture Correction Required. MAXI5 Jay ~ Constru~ ,CHNOLOGI~S, INC. x/,, C.E.T~,., LabOratory Manager Materials Engineering Division ancVor inspected, and are not indicative or'the quantities of apparemly identical or similar products. TECHNOLOGIES INC Maxim Technologies Inc, 2575 Lone Star Drive Dallas, Texas 75222 Telephone: (214) 631-2700 FAX; (214) 920-1891 CLIENT: PROJECT: SERVICES: REPORT OF CONCRETE CONIPRESSIVE STRENGTH ED BELL CONSTRUCTION 10605 HA~RY HINES BLVD ATTN: ROBERT WEBBER DALLAS, TX 75220 MIX DESIGNS SANDY LAKE ROAD PAGE 1 OF 1 PROJECT NO.: 9863997 REPORT NO.: 149415 DATE OF SERVICE: 7/17/99 AUTHORIZATION: REPORT DATE: 7/24/99 Tesz compressive strength specimens prepared to confirm strength properties of the mix design. CONTRACTOR: ED BELL CONSTRUCTION CONCRETE SUPPLIER: SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 3 U Maximum AIR: 5 . 0% METHOD OF TEST SAMPLING: MOLDING & CURING: SLUMP: TEMPERATURE: AIR CONTENT: UNIT WEIGHT: CAPPING/PADS: TESTING: ASTM C-172 ASTM C192 ASTM C143 ASTM C1064 ASTM C231 ASTM C138 ASTM C1231 ASTM C39 PROJECT DATA CLASS OF CONCRETE: 5 sac]< slip for mix DATE OE PLACEMENT: 7/17/99 TIME SAMPLED: 8:15~M BY: Gary Kamra~h TEMPERATURE(DegF)-AtR: 76 CONCRETE: 79 TRUCK NO: N/A TICKET NO: N/A MEASURED SLUMP (in.): 3.00 AIR CONTENT(%): 5.0% UNITWEIGHT(pcf): 149.2 LOCATION OF PLACEMENT: In!ab Mix Design. 3000 PSI slip form mix. Sandy Lake Road. REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS CYLINDER MAXIMUM COMPRESSIVE MARKED DATE AGE DIAMETER AREA LOAD STRENGTH SET NO TESTED (days) (in,) Isq.Jn.i {lbs. force) (psi) 1 1 7/24/99 7 6.00 28.27 127030 4490 1 2 7/24/99 7 6.00 28.27 118420 4190 1 3 7/24/99 7 6.00 28.27 121300 4290 1 4 8/14/99 28 1 5 8/14/99 28 FRACTURETYRE REMARKS UNBCNIDED CAP UNBCNDED CAP UNBCNUDED CAP 1 6 8/14/99 28 Technician: Gary Kamrath Star5ed: 7: 00~M Stopped: !!: 30.~M Report Distribution: {II E9 BELL CONSTRUCT"ON M~AX,-H~EC~NC. /~ME DiVisiOn Client: Project: Portland Cement Concrete Mix Design Report Ed Bell Construction I0605 Harry Hines Blvd. Dallas, Texas 75220 Arm: Jay Simms Concrete Mix Design Sandy Lake Road Ma:dm Technologies Inc. 2E7E Lone Star Dr.' Telephone: ¢14) ~1~ F~ (214) Project No.: 9863997 Report No.: 149417 Service Date: 071799 Page 1 of 1 Identification: 6 sack band work mix Requirements Design Specification i Compressive Strength (psi / days) 3600 psi NA Cement Content (sack) Equivalent N/A N/A i Slump (inches) 4.0 max NA Water Cementitious Ratio (lbs/lbs) 0.44 NA /Entrained Air Content (%) 5.0% NA Materials Source Size or Type Fly Ash ~oarse Aggregate Fine Aggregate ~,dmixmre #1 WR Grace Admixture #2 WR Grace Holman Cement Co. N/A 1 [/2 Lattimore Marock Water Reducer Air Entrainment Type IAI N/A Crushed Stone NaturaI Sand ASTM C494 ASTM C260 Specific Gravity 3.15 N/A 2.67 2.62 NA NA Proportions One Cubic Yard SSD Basis Cement Fly Ash Coarse Aggregate Fine Aggregate Water Admixture #I Water Reducer ASTM C494 Admixture #2 Entrained Air ASTM C260 Totals Weight (lbs) 564 N/A 1925 1180 250 16.9 oz 3.0 oz 3919 Absolute Volume (cubic Feet) 2.87 N/A 11.55 7.22 4.01 NA 1.35 27.00 Unit Weight of Fresh Concrete(lb/cubic foot): 145.2 Adjust water to maintain 4" slump. Adjnst air entraining agent to maintain 5.0% air content. Weights are S.S.D.- Moisture Correction Required. Jay/Gffn/aff~/ff~, C.F~., L~boratory Manager Cor~/tru~n Materials Engineering Division TECHNOLOGIES INC Maxim Technologies Inc, 2575 Lone Star Drive Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-]891 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: ED BELL CONSTRUCTION 10605 HA~RY HINES BLVID ATTN: ROBERT WEBBER DALLAS, TX 75220 PROJECT: MIX DESIGNS SANDY LAKE ROAD PAGE 1 OF 2 PROJECT NO.: 9863997 REPORT NO.: 149417 DATE OF SERVICE: 7/17/99 AUTHORIZATION: REPORT DATE: 7/24/99 SERVICES: Test compressive strength specimens prepared to confirm strength properties of the mix design. CONTRACTOR; ED BELL CONSTRUCTION CONCRETE SUPPLIER: SPEC~FtCATION REQUIREMENTS STRENGTH: 3600psi ,~ 28 DAYS SLUMP: 4" Maximum AIR: 5.0% METHOD DE TEST SAMPLING: MOLDING & CURING: SLUMP: TEMPERATURE: AIR CONTENT: UNIT WEIGHT: CAPPING/PADS: TESTING: ASTM C-172 ASTM C192 ASTM C!43 ASTM C1064 ASTM C231 ASTM C138 ASTM C!231 ASTM C39 PROJECT DATA CLASS OF CONCRETE: 6 sack hand work mix DATE OF PLACEMENT: 7/17/99 TIME SAMPLED: 9:30A~M BY: Gary Kamrath TEMPERATURE{DegF)-AIR: 79 CONCRETE: 79 TRUCK NO: N/A TICKET NO: MEASURED SLUMP (in.): 3.50 AIR CONTENT(%): 4.6% UNIT WE[GHT(pcfh 149.2 LOCATION OF PLACEMENT: Inlab Mix Design. 3600 PSI hand work mix Sandy La~e Road. CYLINDER MARKED DATE AGE DIAMETER AREA SET NO. TESTED fdavs) {in.) Isq.in.) 1 1 7/24/99 7 6.00 28.27 1 2 7/24/99 7 6.00 28.27 1 3 7/24/99 7 6.00 28.27 1 4 8/14/99 28 1 5 8/14/99 28 REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE LOAD STRENGTH (lbs. force) !psi) 130170 4600 126430 4470 119S50 4230 FRACTURETYPE REMARKS UNBONDED CAP UITBONDED CAP UNBONDED CAP 1 6 8/14/99 28 Report Of Tests Continued On Page 2 ED BELL CONSTRUCTION REPORT NO. 149417 PROJECT NO. 9863997 PAGE 2 OF 2 DA/EOFSERVICE: 7/17/99 SET NO. 1 REPORT OF TESTS ADDITIONAL COMMENTS See report ~ 149416 for mime. Technician: Gary Kamrat h Report Distribution: TECHNOLOGIES INC Maxim Technologies inc. 2575 Lone Star Drive Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 CLIENT: ED BELL CONSTRUCTION 10605 }{ARRY HINES BLlrD ATTN: ROBERT WEBBER DALLieS, TX 75220 PROJECT: MIX DESIGNS SANDy LAKE ROAD REPORT OF TESTS SERVICES: Fine and Coarse Aggregate Testing PROJECT NO.: 9863997 REPORT NO: 148661 DATE OF SERVICE: 6/22/99 AUTHORIZATION: Ongoing REPORT DATE: 7/26/99 REPORT OF TESTS 1 1/2" Crushed Limestone ASTM C-136 Sieve Size % Passing Reqd Spec. 2" 100% 100% 1 1/2" 99.0% 95-100% 3/4" 49.0% 40-70% 3/8" 14.0% 10-30% ~4 3.0% 0~5% Natural Concrete Sand ASTM C-136 Sieve Size % Passing Reqd Spec. 3/8" 100% 100% #4 98% 95-100% ~8 84% 80-100% ~16 74% 50-85% #30 64% 25-65% #50 28% 10-30% ~100 4% 0-10% ~200 0% 0 3% Page 1 of ! Fineness Modulus: 2.53 Technician: Oscar Garza Report Distribution: GRACE October 16, 1998 Grace Construction Products Grace & Co - Corm a323 Cri~es Srreel Box 2585.77252 ~,;,.s'on TX 77003 Ed Bell Construction Gentlemen: This is to certify that DARATARD-17, a water-reducing set-retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Spech~ications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the S~andard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. ,rely, //. Tom C. Henson District Manager Subscribed and swam to, before me, this 16th dayof October, 1998 A.D. Lorene B. Raso, Notary Public In and For the State of Texas GRACE October 16, 1998 Grace Construction Products Z-323 7' 'es S'ree, :C' E.:, 2585.77252 -: ~c- -X 77C03 Ed Bell Construction Gentlemen: This is to certify that Oaravair 1000, an air-entraining admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specification for Air- Entraining Admixtures for Concrete, ASTM Designation: C260 (AASHTO M154). Daravair 1000 does not contain calcium chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Sincerely, District Manager Subscribed and sworn to, before me, this 16th day of October, 1998 A.D. /" ' ' ' t(; ':'} /1~ L~ ¢c(. ·~/, ~..gE; Lorene B. Raso, Notary Public In and For the State of Texas