Loading...
Vista Point II-CS031218CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE NO.: PD-199-HC, Vista Point II, MacArthur Ridge P & Z HEARING DATE: C.C. HEARING DATE: December 18, 2003 January 13, 2004 STAFF REP.: Marcie Diamond, Assistant Planning Director LOCATION: Southwest comer of S.H. 121 and MacArthur Boulevard. SIZE OF AREA: Approximately 26 acres of property. CURRENT ZONING: HC (Highway Commercial) REQUEST: PD-199-HC(Planncd Development-199-Highway Commercial), Concept Plan to allow the development six office/assembly/warehouse buildings, totaling approximately 200,000-square feet, and five retail/restaurant pad sites. APPLICANTS: Delnian Salmon Jackson Shaw Company 4890 Alpha Road, Suite 100 Dallas, Texas 75244 972-628-7400 FAX: 972-628-7444 Jeff Libby Standridge Companies 14860 Monfort Dr. # 241 Dallas, Texas 75254 214-363-1998 FAX: 214-363-1997 HISTORY: Page I of 8 The subject property is part of Lot 3, Block G, a 49.20-acre tract within the Vista Ridge Addition. The property lies within Denton County and was originally part of the City of Lewisville when recorded in September of 1986. Since that time, the City of Item # 10 Coppell has annexed this and other portions of the Vista Ridge Business Park. In September 2001, City Council approved a Site Plan and Final Plat to allow for the construction of a one-story, 71,000 square-foot office building on seven acres of this 26-acre parcel of land. The Site Plan would have expired September 11, 2003; however, on September 9, 2003, City Council approved a six-month extension. The approved Site Plan will now expire in March 2004. In September 1999, a request for a PD for a gas station, convenience store and car wash on 1.5 acres at this corner of S.H. 121 and MacArthur Boulevard was recommended for denial by staff. Due to this recommendation, the applicant requested a postponement until December of that year to allow for a redesign of the site plan and elevations to address staff design concerns, but staff still strongly opposed the use at this location. On December 16, 1999, the Planning and Zoning Commission recommended denial of this request, and it was not appealed to City Council. TRANSPORTATION: S.H. 121 is under construction to freeway standards with access roads, within 450 feet of right-of-way. SURROUNDING LAND USE & ZONING: North - S.H. 121; City of Lewisville South - PD-132-SF-9; The Peninsulas of Coppell, and PD-149-SF- 7 Vistas of Coppell East -vacant, HC (Highway Commercial) and office park; LI (Light Industrial), City of Lewisville West - Vistas of Coppell; PD-I49-SF-7-Single-Family COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for mixed-use development, including retail/conm~ercial, office parks, schools, churches, and other compatible non- residential uses. I)ISCUSSION: Page 2 of 8 The applicant desires to construct a similar project to one that they developed on the north side of S.H. 121 in the City of Lewisville. Initially, this request was to rezone this property from Highway Commercial (HC) zoning to a Planned Development for HC uses to Item ,7 10 Page 3 of 8 allow tilt-wall conslruction, which is no longer permitted in the HC District. However, this PD Concept Plan is also requesting variances to the uses permitted by right in the HC district, landscape and sign ordinances. This submission has also not addressed staff's concerns about location of loading areas, screening, lighting, building materials and tree preservation. Proposed Uses: This PD is requesting approval for approximately 210,000 square feet of office/assembly/warehouse use and five retail pad sites. The existing Highway Commercial zoning is defined in the Zoning Ordinance as follows: "Sec. 12-22-0. General purpose and description. The "HC" highway commercial district is intended primarily as a high intensity area permitting a mixed-use for office, commercial-retail, and highway oriented uses, such as hotels, restaurants, and low and mid-rise offices, and should be located generally along high-volume thoroughfares. The site characteristics for each area should be designed in a manner to create an attractive appearance from LH. 635 and S.H. 121, and an impressive gateway into the community. Because these areas are designated as major thoroughfare entry points, emphasis has been placed on building arrangement, setbacks, parking, and landscape treatment, which are intended to be elements influencing the character of entrance into the city. It is the intention of the "highway commercial" zoning district to create att attractive attd unique entrance into the city". Given the stated intent and purpose of this district, warehousing use is only permitted by Special Use Permit (or could be established as part of this PD). Staff cannot support the proposed office/assembly/warehouse use along S.H. 121, as well as being in close proximity to the existing residential neighborhoods to the south. The Site Plan does not define the proposed ratio of office to assembly to warehouse for these buildings. Even though the proposed parking ratio could support 100% office, these buildings could be occupied by a high percentage of uses that are only appropriate in our industrial area, specifically, warehouse and assembly. Retail uses are generally more in keeping with the intent of the HC district; however, discussion on the specific uses proposed by SUP Ibr the corner of S.H. 121 and MacArthur is a separate agenda item and will be discussed as a separate zoning case. Approximately two years ago, a Detail Site Plan for a 70,000 square- foot office building was approved for a portion of this tract of land. A Item # 10 Concept Plan for the remaining parcel also indicated office as the proposed use. The proposed uses ere enthusiastically supported by staff, the community, Commission and Council, even though there was some concern over the materials used. At that time, masonry was not required in the HC district as it is now. In September of this year City Council approved a 6-month extension to the Detail Site Plan; therefore, this office plan is still viable. Staff feels that pure office is more appropriate and is in compliance with the existing ttC district and addresses the goals of the Comprehensive Plan. Loading Areas/Screening: Due to the characteristics of the office/assembly/warehouse use, overhead doors are planned to be along 100% of the rear wall of each building served by massive paved loading areas. These areas are in close proximity and visible from the residential neighborhoods. The Site Plan indicates a 6-foot screening wall along a portion of the southern property line which directly abuts the Vistas of Coppell, Phase lIB residential subdivision. However, east of that area, along Forest Hill Drive, and abutting the levee and the City's hike and bike trail, abutting The Peninsulas residential subdivision, no perimeter screening wall is shown. The applicant is stating that due to the intervening HC zoned property (the levee), the screening wall is not required. However, staff strongly feels that given the topography and the lack of any other visual barrier between the proposed office/assembly/warehouse and retail and the homes in The Peninsulas, this screening wall needs to be extended along Forest Hill Drive to MacArthur Blvd. The elevation of this wall also needs to be addressed. As currently proposed, it is a 6-foot "thin- wall masonry" screening. The elevations do not specify color or include any sort of articulation, columns, etc. This wall, as currently proposed, will be approximately 1,150-linear feet, and per staff recommendation, this wall needs to be extended another 850-linear feet. A solid, blank wall is not acceptable. Staff is further recommending that in the event this PD is approved, then this entire screening wall and landscaping adjacent to this wall be built with the initial construction. Other Site Plan Issues: Although the retail pad sites are conceptual in nature, it must be pointed out that Tract 6 is deficient in terms of number of parking spaces and amount of land devoted to landscaping. Therefore, the size of the building on this tract needs to be significantly reduced. Additional landscape comments are included below. Additional information will also be required to assure that the fire lane criteria are being met in all the tracts. Given the residential adjacency, staff had requested additional information about site, parking lot and building lighting, which has not Page 4 of 8 Item # 10 Page 5 of 8 been provided. Finally, the driveway locations need to be approved by TxDot, and a deceleration lane must be added if required by TxDot. Signage: The Site Plan is indicating a "phase line" between tracts one and two of the office/assembly/warehouse area. The applicant has not specified an intent to plat these phases into two or more lots or retain this property as one lot. The platting of this property will impact the amount and location of required landscaping, as well as the number of monument signs permitted. If this entire office/assembly/warehouse area remains as one lot, then only two 60 square foot monument signs would be permitted. Assuming that the line between phase 1 and 2 will ultimately be a lot line, then two 40 square-foot monument signs would be permitted on Lot 1 and two 60 square-foot signs on Lot 2. The applicant is requesting five 30 square-foot signs for the office/assembly/warehouse area. The location of several of the monument signs is also not compliant with the Sign Ordinance. These variances to the Sign Ordinance will need to be stated as a specific request as part of this PD. The applicant also submitted attached sign criteria. Most of the language and regulations are not applicable to this review and reiterates the sign requirements in the Zoning Ordi~ance, except for subsection E, which states, in part, that "colors are limited to white, ivory, or black, unless this requirement conflict(s) with corporate identi7 (emphasis added). The City of Coppell Sign Ordinance allows corporate identity up to 20% of the area of the sign to be logos of any color. The applicant's sign criteria needs to be amended to reflect this section of the Sign Ordinance, or requested as an additional variance. Landscape Plan: To conduct a proper analysis of the Landscape Plan, an understanding of the ultimate lot layout is necessary to determine the compliance with, or variance to, the Landscape Ordinance. In virtue of this being a PD, trade-ofl~ may be considered, however, deficiencies in amount of total landscape areas will not be supported. Assuming a minimum of two lots in the office/assembly/warehouse area, it appears that a relief from the 10' required perimeter landscaping for both sides of internal lot lines is being requested between these two lots and along some lot lines in the retail pad sites. Staff can not support this requested relief. In the office/assembly/warehouse area, Tract 2 (Buildings 4, 5 and 6), there is a deficiency of approximately 12,000-square feet of non- vehicular and interior landscaping, in addition to not providing for perimeter landscaping along the common property lines. Tract 1 (Buildings 1,2, and 3), has a surplus of approx. 650-square feet; however, this does not begin to address the shortage in Tract 2. It is Item # 10 recominended that the 6-foot screening wall adjacent to Forest Hill Drive will be required. In the event that it is not, significantly more tall evergreen trees, which are full to the base, will be required to provide a visual screen between this property and the residential property to the south. The retail tracts are providing sufficient non-vehicular, interior landscaping and perimeter landscaping adjacent to streets and the office/assembly/warehouse area but are deficient in internal lot line landscaping. As detailed on the Tree Survey, a significant number of trees will be removed to allow for the development of this property. It appears that increasing the landscape setback along MacArthur Blvd. by approximately 20 feet could preserve approximately sixteen 10-12-inch caliper Cedar Elms and Live Oak trees that were planted as street trees years ago. The preservation of these trees will enhance the streetscape of MacArthur Blvd and addresses our Primary Image Zone landscape criteria. Elevations: The final issue relates to the elevations of the buildings. While the elevations are conceptual in nature and will be further defined for all buildings (except for Tract 4 - See S-1211 in this agenda) when detail plans are submitted, this is intended to provide for the overall character of the development. The applicants have agreed to carry the materials, signage criteria and design elements from the office/assembly/warehouse area to the retail pad site areas. As mentioned in the beginning of this report, the initial purpose of placing this property under a PD is to allow for a variance to Section 12- 33-5. Type of Exterior Construction of the Zoning Ordinance, which requires that buildings in this district be a minimum of 80% masonry, exclusive of doors and windows. Masonry is defined as "brick and stone of earth tones colors", and does not permit tilt wall. The elevations for the office/assembly/warehouse buildings appear to be 100% tilt wall construction with 2.5 feet of brick veneer along the base of the building with stone accents to enhance the entries, which is a typical industrial building design. The rear elevations (100% tilt wall with metal doors) face the residential area and Forest Hill Drive. The calculations on thc elevation sheets are in error, in that they do not exclude windows and doors from the percentage calculations, and they even included the metal roof to increase "percentage of masonry." Metal is not considered a maso~y product. Page 6 of 8 Item # 10 The Planning Corrnnission discussed the aesthetics and the detail of building design at great length when the 70,000 square foot office building was considered for this property in September 2001. The Commission spent considerable time assisting the developer in creating an office building that the community would embrace. These buildings ignore that input. The buildings proposed for the retail pad sites will utilize the same materials; however, they will have a significantly higher percentage of brick veneer, with stone, tilt wall and stucco being utilized as architectural accents. The percentage of masonry on the buildings also needs to be recalculated per Section 12-33-5 of the Zx~ning Ordinance. Summary: The City has been proactive over the past year in rezoning properties along S.H. 121 from Light Industrial to Highway Commercial to encourage retail/office and commercial uses and prohibit tilt-wall industrial/warehousing along S.H. 121 and adjacent to developed residential areas. As specifically stated in the Zoning Ordinance: "/t is the intention of the "highway commercial" zoning district to create an attractive and unique entrance into the city". This application is in direct conflict with that effort. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staffis recommending DENIAL based on: · This project does not adhere to the stated purpose and intent, or the regulations, of the Highway Con-nnercial District. · The industrial nature of this project, in terms of uses and choice of building materials and design, including the lack of specificity to the ratio of assembly/warehouse/office, is in direct conflict to the efforts of the City to encourage commercial/office/hotel and similar freeway oriented uses along S.H 121. · The negative impact that this development (proximity of loading areas and lack of screening) will have on Forest Hill Drive and the residential areas beyond. · The deficits in the proposed landscaping and screening, lack of commitment about site, parking lot and building lighting. ALTERNATIVES It 2) 3) 4) Page 7 of 8 Rccommend approval of the request Recommend disapproval of thc request Reconnnend modification of the request Take under advisement for reconsideration at a later date. Item # 10 ATTACHMENTS: 1) Proposed Signage Critcria (2 pages) 2) Site Plan 3) Elevation for Front and Sides of thc office/assembly/warehouse 4) Elevations for the Rear and Side of the office/assembly/warehouse 5) Elcvation for the retail buildings 6) Landscape Plan 7) Tree Su~'ey 8) Tree list Page 8 of 8 Item # 10 Vista Point II / MacArthur Ridge Preliminary Sign Criteria The purpose of this sign criteria m to create a graphic environment that is individual and distinctive in identity for the Tenant and also compatible with other signs in the center. The total concept should give an impression of quality, professionalism and instill a good business image. Lettering shall be well proportioned and its design, spacing and legibility shall be a maior criterion for approval. The following specifications are to be used for the design of your sign; however, in all cases final written approval must be obtained from the Lessor prior to the manufacturing or installation of any signage. Lessor shall make all final and controlling determinations concerning any questions of interpretation of this sign policy. NOTICE: Written approval and conformance with these specifications does not imply conformance with local City and County s~gn ordinances. Please have your sign company check with local authorities to avoid non compliance with local codes. REOUIRED SIGNS 1. Tenant shall identify its premises by erecting one (1) sign which shall be attached directly to the building fascia as described hereinafter. For buildings and leaseholds with one (1) front fagade, (front fagade being defined as the building surface directly facing a dedicated street, or where street frontage does not exist, it shall be defined as the width of the lease space which contains the main entry), attached signs located at a height of 36 feet or less are permitted a maximum aggregate effective area equal to one-square foot per lineal foot of building or leasehold frontage as applicable, or 300 square feet, whichever is less. Where the Leased Premises is at maximum aggregate area on any one fagade equal to one S.F. per linear feet of fagade width and a maximum total aggregate area of those of building or tenant frontage on a dedicated street or 300 S.F., whichever is less. 2. Tenant shall instatl approved signage no later than thirty (30) days after receipt of a Certificate of Occupancy. TYPE OF FASCIA SIGN Non-illuminated or reverse lighted individually pin mounted channel letters. SIZE OF SIGN 1. Depth - 5 1/z"; height - not-to-exceed 36". Multiple Rows - not to exceed 36" in total height including spaces between rows, Minimum Letter Size- 10", In any case the overall length or spread of the sign cannot exceed 70% of the total linear measurement of the main entry storefront of leased space or 4-0' 0". whichever is less. In the case of an irregularly shaped sign or logo sign with letters and/or symbols directly affixed to the wall of a building, the area of the s~gn shall be the entire area within a single continuous rectilinear perimeter of not more than the proportional maximum height and width limitations noted above. TYPE OF SIGN 1, Lessor will have final review over letter font, style and height. 2. Logos in addition to slgnage must be approved. They must be proportionate to height of fascia and sign. 3. Box type signs will not be allowed. COLO.R_ Colors are subject to approval by Landlord or his representative. Matte finish required. Colors are limited to white, ivory, or black, unless this requirement conflict with corporate identity. ga Point / MacArthur Ridge Sign Criteria acember 9, 2003 2age 2 of 2 _CO~NSTRUCTION OF LETTERS 1. Returns and Fronts . .063-aluminum gauge (minimum) 2. Back of letters shall have a minimum of 1/8" clear Plexiglass face. 3. No exposed trim caps permitted. 4. Letters to be pin mounted 1" off building fascia. 5. U.L label is required. G. ILLUMI~NATION AND WIRING ]. Individual letters to be ~acklit with neon tubing concealed in the letter and projecting the light source back on the building fascia. 2. Secondary Wiring - All transformers and secondary wiring are to be concealed behind parapets or within soffits. 3. Electrical power shall be brought to required location at L ' shall be below roof deck and not visible, essee s expense. Routing of conduit H. _PLACEMENT AND INSTALLATION 1. General Notes a. Tenant signage shall be as close to a center of-frontage location as possible, subject to allowance for positioning corner. b. Attachment of signage to be U.L. approved. No exposed wrong is permitted. c. All fasteners used are to be non corrosive stainless steel. d. Tenant will be responsible for all damage to the building incurred during sign installation and removal and must patch and paint holes in fascia caused by signage attachment and wirmg upon Lease termination. SU_BMITTAL FOR APPROVAL 1. Prior to awarding a contract for fabrication and installation, Tenant shall submit three (3) scaled drawings for final review and approval to Lessor. 2. Elevation of building fascia and sign shall be drawn using a minimum ,~ = -u scale. lZ" ] .... 3. Drawmg shall indicate the follow~ngspecifications: Type, color, and thickness of Plexiglass, type of materials, color and finish used on front and return, type of illumination and mounting method. Tenant's sign contractor shall first visit the site to verify existing conditions prior to preparation of shop drawings: information needed to prepare submittals shall also be obtained during the visit. 4. Drawings must include fascia cross section showing electrical connections. PERMITS All city permits and approvals from the City of CoppelI are required prior to s~gn fabrication. TRAILER SIGNS OR TEMPORARY SIGNS WILL NOT BE PERMITTED. -T_H_E_FOLLOWING ARE NOT PERMITTED l. Roof signs or box signs 2. Exposed seam tubing 3. Animated or moving components 4. Intermittent or flashing illumination 5. Iridescent painted signs 6. Letter mounted or painted on illuminated panels 7. Signs or letters painted directly on any surface except as herein provided Signs installed or placed along perimeter of shopping center