Loading...
ST9604-LR 98081922) 23) 24) Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN-PLACE DENSITY TESTS CLIENT: Rebcon, Inc. PROJECT: Fairway Drive, Coppell, TX DATE: JOB NO.: MATERIAL DESCRIPTION: 1) On-Site Fill - Brown Sandy Clay with Gravel ASTM D 698 STANDARD PROCTOR: 1) 110.0 pcf @ 16.0% Moisture LOCATION PROCTOR LIFT BELOW Fill Area North of RR Tracks SUBGRADE west side 1 2'-3' 20.3 centerline 1 2'-3' 20.6 east side 1 2'-3' 20.3 19 August 1998 98.1089 MOISTURE DRY PERCENT REQUIRED CONTENT DENSITY COMPACTION COMPACTION % PCF % % 104,9 95.4 95 + Optimum to +5% 105.4 95.8 105.9 96.3 TECHNICIAN: DISTRIBUTION: CDJ (1) Rebcon, Inc. (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148