Freeport NIP(2.2)-LR010907FIELD D~NG
Report~ 94011204~016
Se,v. 2,,) 001
'~,,1~1 Valwood ~way, Suite 440
Ca~- T~006
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: September 07, 2001
Project: Sales Office & Warehouse Fac.
Coppell, Texas
Project Number: 94011204
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pcf) (%) (% compaction)
ASTM D-698 Dk & med brown clay
23.0 97.0 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
15" Storm Drain, Line A
6 Sta. 0+36 1 st 1 6 22.0 93,6 96
7 Sta. 0+36 2nd 1 6 22.2 92.0 95
8 Sra. 0+36 Final 1 6 22.0 92.0 95
9 Approximately 75' E of Sta. 3+39.7 1 st 1 6 22.1 92.6 95
10 Approximately 75' E of Sra. 3+39.7 2nd 1 6 22.0 91.8 95
11 Approximately 75' E of Sta. 3+39.7 Final 1 6 22.1 92.6 95
Comments:
Test results on this report meet project specification.
Services - Per[orm in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM 02922, ASTM D3017
Gauge ID: 32769
Field Results Reported To: Contractor ~'i/,,~J '~
Technician: JimmyAtnip B~C n '~~,lnc.
Report Distribution:
(1) TNA Nodh American, Inc. (1) FACServices Inc Reviewed by:
(1) Carrell Poole & Yost Architecture (1) David Kent (--~ric J'~le~J~land, ~.E
(1) R L Goodson Consulting Engineers (1) City of Coppell Bldg Insp Senior Proje~fl~-Engineer
(1) Pacific Builders Inc (1) City of Coppell - Constr Insp
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical
materials.