Freeport NIP(2.2)-LR010808WATER INJECTION OBSERVATION
ENGINEERING, 1NC.
Date of Service:
Client No.:
Client:
Location:
Procedure:
08/08/01
3053
TNA North American, Inc.
1321 Valwood Parkway, Suite 440
Carrollton, TX 75006
Report No.:
Project No.:
Project:
94011204.0012
94011204
Sales Office &Warehouse Fac.
Coppell, Texas
Building Pad
General Contractor:
Injector:
Pacific Builders
Kinley
On this date, a representative of HBC Engineering, Inc. observed the injection of water at this
site. During the injection process, the following observations were recorded.
Pass No.: 4th No. of Probes: 4 Probe Length: 12 feet
OBSERVATION
SPECIFICATION Yes No N/A
Surfactant added to each load. X
ln,jection pressure 50 to 200 psi at manifold. X
Injection downward in 18 inch intervals. X
Total depth of injection was 10 feet. X
Spacing of injection was 5 feet maximum. X
Iniection to refusal at each location. X
Comments:
Technician: D. Boyd/T. Smith
Report Distribution:
(1) THA North Amcrican, Lac.
(1) Carrell Poole & Yost Architecture
(1) R. L. Goodson Consulting Engineers
(1) Pacific Builders. Inc.
(I) FACServices, Lac
(1) David Kent
(1) City of Coppell ~ Bldg. Insp