Town Center L4B1-LR010813ALPHA TESTING, INC. 220~ Wisconsin St., Suite 100 Dallos, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CONSTRUCTION MANAGEMENT GROUP DATE 08/13/01 DALLAS, TEXAS PROJECT COPPELL TOWN CENTER OUR REPORT NO. 01612-9 COPPELL, TEXAS TEST DATA: NO. DATEDEPTH"~ NUMBER MOI~RJRE DRY DIENS[TY MOISTURE DRY DENSITY COMPACTION COMMENT* 15 08/13/01 FG 01614~2 14.0 114 14.4 111 98 1-A 16 08/13/01 FG 01614/2 14.0 114 15.6 110 97 1-A 17 08~13101 FG 01614/2 14.0 114 14.5 113 99 1-A 18 08/13/01 FG 01614~2 14.0 11'4 14.6 114 100 1-A 19 08/13/01 FG 0161412 14.0 114 16.0 111 98 1-A 20 08/13/01 FG 01614/2 14.0 114 15.4 114 100 1-A 21 08/13/01 FG 0161412 14.0 114 14.4 112 98 1-A TEST LOCATION: 15 10' NORTH AND 30' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #1 16 20' NORTH AND 80' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #1 17 15' NORTH AND 50' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #1 18 25' NORTH AND 60' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #2 19 15' NORTH AND 40' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #2 20 40' NORTH AND 80' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #2 21 10' NORTH AND 70' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #3 CC: Constr. Mngt. Group; Jeff Miller, City of Coppell; Larry Dave$, Lee Stone 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS;ATIONS .~ 2 NATURAL SU~GRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R~oe~ 3 LIME STABILIZED C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENTTREATED D RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting ALPHA TESTING, INC. 220~ Wisconsin St., Suite Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR CONSTRUCTION MANAGEMENT GROUP DATE 08/13/01 DALLAS, TEXAS PROJECT COPPELL TOWN CENTER OUR REPORT NO. 01612-9A COPPELL, TEXAS TEST DATA: TEST ELEV'i NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY CaM PAC~rlON COMMENT* NO. DATE i % PCF % PCF 22 08/13/01 FG 01614/2 14.0 114 14.6 111 97 1-A 23 08/13/01 FG 0161412 14.0 114 14.8 112 98 1-A TEST LOCATION: 22 30' NORTH AND 90' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #3 23 15' NORTH AND 50' EAST FROM SOUTHWEST CORNER OF BUILDING PAD #3 1 FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WiTH SPECIFICATIONS 2 NATURAL SUBGRADE B. PERCENT COMPACTION DO~S NOT COMPLY WITH SPECIFICATIONS ittsc ~ 43' CEMENT TREATEDLIME STABILIZED CD RETEsTPERCENT IN PLACE MOISTURE DO~S NOT COMPLY WITH SPECIFICATIONS ~AT~/~G, INC Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting