First Methodist-LR011219Specimen
Number
Measured
Slump (in .I
Age
(Days)
Date
Tested
Tout Load
(Lbs)
Compressive Strength
(Lbs. /Sq.tn.)
Remarks
FMC 109
FMC 110
FMC 111
FMC 112
5 h
[1 CO 00
N hl x'
11/28/01
12/19/01
12/19/01
HOLD
101,780
128,840
130,040
3,600
4,560
4,600
Test Methods Utilized
ASTM C- 3 C- 39.0 -14
Fracwre Reg lac
(Unless Noted Otherwise)
Cyli n�ets Made By: MR
Construction Materials Testing
and Environmental Consulting
Report Date:
Client:
Project:
Contractor:
Concrete Supplier and Plant:
Location of Placement:
MATERIALS
Mix Number:
Cement:
Fly Ash:
Coarse Aggregate:
Intermediate Aggregate:
Fine Aggregate:
Admixtures:
1
2
Added Water:
Remarks and/or Distribution:
Texas
CMT, Inc.
L
Pavemen
42
0 gallons
Source/
10044 Monroe Dri Dallas, Texas 75229 (214) 352 -6957
REPORT OF C
ecember 19, 2001 Date Concrete Placed: November 21, 2001
First United Methodist Church Coppell
First United Methodist Church New Parking Lot
ill Wilkinson Ltd.
Description
cc: Mr. John Rosenberg First United Methodist Church (2)
Mr. Ray Larson First United Methodist Church
Mr. Eric Royal Royal General Contractors
Mr. Larry Davis City of Coppell
Mr. Bob Colon Hill Wilkinson
L
Texas CM Inc.
TE MIX OBSERVATION
SSD Basch Ws.
Lbs/CuYd)
Reviewed by:
Fax (214) 352-6972 www .texascmt.com
OBSERVATION DATA
Standard 6 "x12"
Area 28.27 Square Inches
Concrete Report No.: 28
Project No 201 -0177
Time Sample Batched: 06:37 am
Time Sampled: 07:25 am
Sample Location: 18' S. of parking lot entrance near intersection
of Vanbebber Westwood Ct., 5' W. of east
edge of fire lane
Truck/Ticket No: 964/3137245
Temperature:
Ambient Range: 38 °F
Concrete Range: 61 °F
Slump Range (inches): 51/2" Weather Conditions: Clear
Time Started: 06:00 am
Time Completed: 09:15 am
Sample Air Content 1.5%
Total Cubic Yards Placed: 20
Re 3trenafh 1Lhs. is in.): 4.000
All letters and reports are for We exclusive use of the client to whom they arc addressed and wall not be reproduced without the full approval of Teo CMT, Inc. The use of our name mist receive our prior written approval. Our
letters and reports apply only to ibe sample tested and/or observed and are not nemW.Iy indicative of to quantities of appartody identical or similar praducu.