Loading...
First Methodist-LR011031Client: First United Methodist Church Coppell, Texas Project: First United Methodist Church New Parking Lot Test Date: October 30, 2001 Report Date: October 31, 2001 Required Density 95% 105% Required Moisture Opt. +5 %n /±3% Material Description clay Maximum Dry Density (Lbs /CuFt) 114.5 109.9 99.4 112.2 103.0 109.9 Optimum Moisture Content Percent 13.0 16.5 18.6 13.0 13.9 10.9 I. Brown Clayey Sand 2. Light Brown Sandy Clay 3. Dark Brown Clay 4. Brown Clayey Sand (YMCA import) 5. Light Brown Clayey Sand wllight weight aggregate occasional limestone 6. Reddish Brown Clayey Sand brown sandy Test NO Mat No. Location/Elevation (and /or) Lilt In -Place Dry Density (Lbs/CuF0 In -Place Moisture Content Percent Compaction Probe Depth 21 6 Paving, West Fire Lane 70 N. of SW corner of parking lot 105.0 17.3* 95.5 6" Construction Materials Testing and Environmental Consulting 10044 Monroe Drive cc: Mr. John Rosenberg First United Methodist Church (2) Mr. Ray Larson First United Methodist Church Mr. Eric Royal First United Methodist Church Mr. Larry Davis City of Coppell Mr. Bob Colon Hill Wilkinson (2) Texas CMT, Inc. Dallas, Texas 75229 (214) 352-6957 Fax (214) 352-6972 REPORT OF IN -PLACE DENSITY AND MOISTURE OF SOIL R ott M 8 (2 0 177) Method: ASTM D2922 D3017 D698 Pa e 1 of 1 Test results do not meet project specifications Our letters and repots are for the exclusive use of the client to whom they are addressed. The use of our name must receive our prior wrinen approval. Our letters and reports apply only to the sample tested and /or observed. and are not necessarily indicative of the quantities of apparently identical or similar products.