Loading...
Securelock-LR040121 GEOTECHNICAL ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400 Grave/Drive Bldg 25 Fort Worth Texas 76118 phone (817) 284 9363 fax.'(817) 284 9430 Concrete Compression Test Report Client: Houghton Capital Project: SecurLock Self Storage Coppell, TX Report Distribution: (1) Houghton Capital (1) Prime Construction Company (1) City of Coppell (1) City of Coppell TMI Report No.: FC03-63414-003 Report Date: 01/21/2004 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 01/08/2004 Slump 4 in max Sampled By Tim Pickens Air Content n/a Weather Partly Cloudy Concrete Temperature n/a Supplier/Mix Southern Star/9373 Ambient Temperature n/a Air Content Method ASTM C-231-B Field Data Set #1 I Ticket Number: Slump: Concrete Temperature: Placement Location: Sample Location: 43480 Time Batched: 13:00 2 in Air Content: 1.4 % 61 ° F Ambient Temperature: 66° F Manholes at Sanitary Sewer-l; Sta 1+15, Sta 1+39, Sta 4+65, Sta 6+27 Sta 1+15, Sta 1+39, Sta 4+65, Sta 6+27 Time Sampled: 13:45 Unit Weight: n/a Yardage (c.y.): 10 of 10 Concrete Compression Test Results Cylinder Age Max Load Area Strenqth Fracture Set # # Test Date (days) (lbs. force) (sq.in.) (psi~ Type 1 SLC01080401 01/15/2004 7 136980 28.27 4840 1 SLC01080402 02/05/2004 28 1 SLC01080403 02/05/2004 28 1 SLC01080404 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. WATER ADDED: n/a APPROVED BY: n/a TERRA-MAR, INC. R. Carl Lee, Si :.T. Materials Testing Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI, o l Page I of I GEOTECHNICAL, ENVIRONMENTAL AND MATERIALS ENGINEERS DALLAS FORT WORTH HOUSTON AUSTIN LONGVIEW 2400 GraveI Drive, Bldg 25 Fort Worth, Texas 76118 phone. (817) 284-9363 fax'(S17) 284-9430 Concrete Compression Test Report Client: Project: Houghton Capital SecurLock Self Storage Coppell, TX Report Distribution: (1) Houghton Capitat (1) Prime Construction Company (1) City of Coppell (1) City of Coppell TMI Report No.: Report Date: FC03-63414-005 01/21/2004 Specifications Test Data Strength 4000 psi @ 28 Days Placement Date 01/09/2004 Slump 4 in max Sampled By Ryan Bar~on Air Content n/a Weather Clear/10-15 mph Concrete Temperature n/a Supplier/Mix Redi-Mix/604 Ambient Temperature n/a Air Content Method ASTM C-231-B Field Data Set #1 Ticket Number: Slump: Concrete Temperature: Placement Location: 123255 Time Batched: 15:14 2 in Air Content: 4.8 % 65° F Ambient Temperature: 55° F Manhole Sanitary Sewer Line 1; Sta6+75& Sta7+84 Sample Location: Sta 6+75 Time Sampled: 15:45 Unit Weight: n/a Yardage (c.y.): 5 of 5 Concrete Compression Test Results Set # Cyl~der 1 SLC01090401 01/16/2004 7 1 SLC01090402 02~06~2004 28 1 SLC01090403 02/06/2004 28 1 SLC01090404 Hold Normal cylinder size: 6" x 12" Age Max Load Area /~;'~ I Fracture Test Date (days) (lbs. force) (sq,in.) Type 141900 28.27 Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. WATER ADDED: n/a APPROVED BY: n/a TERRA~MARJ. II / R. Carl Lee, S.E.T. Materials Testing Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this repod, or any part therein, is strictly prohibited without the express written consent of TMI. Page I of l