Loading...
Magnolia Rest-LR0309088908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 R n n p E n a i n ee rs 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630.9745 CONCRETE COMPRESSIVE STRENGTH TEST Client: Purple Mountain Construcflon Services Report No.: 192365 Attn: Mr. JeffBurkham Project No.: 037748 4712 Memphis St. Date of Service: 08/08/2003 Dallas TX 75207 Report Date: 09/08/2003 Project: DelimanGrill Gj oy 605 N. Denton Tap Road Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standazds. PROJECT DATA RACTOR: PUrple MDUntaln Con$tlucllon MIX DESIGN LD.: 7752 CONT HanSOn PLACEMENT DATE: 08/08/2003 CONCRETE SUPPLIER: WEATHER CONDITIONS: C1eaT PLANT: 27 TIME SAMPLED: S:40am BATCH TIME: 5: am SPECIFICATION REQUIREMENTS TEMPERATURE (P)-AIR S4 F CONCRETE: 96 F STRENGTH: 3000 p51 ~ 28 Days TRUCK NO: 823 TICKET NO: 402275 SLUMP (in): „ S tnaXlrIBlrll AIR CONTENT (%): 3.0 UNIT WEIGHT (pcf): NA AIR (%): o - 7 S% 4.S ~o OVERALL PLACEMENT LOCATION: TEST METHOD: ASTM C-172 Paving area fmm northeast building comer northward to existing pavement of adjacent exit door (approximately middle of f buildin rth i ASTM C-31 g o nt no parking lo[ and west to ezpansion jo ASTM C-143 north wau). ASTM C-231 ASTM C-1064 SAMPLE LOCATION: 5' east of expansion joint north of ASTM C-138 building exit ASTM C-39 in ) 27 8 " " . sq. . (area 2 x 12 Concrete Compressive Cylinder 6 CYLINDER MARKED SET NO. 1 1 MEASURED SLUMP (Inches) 8.5 DATE TESTED 08/11/2003 AGE (days) 3 MAXIMUM LOAD (Ibs. force) 79040 COMPRESSIVE STRENGTH (Psl) 2790 1 2 8.5 08/15/2003 7 86170 3050 1 3 1 4 8.5 8.5 09/05/2003 09/05/2003 28 28 110330 105430 Average 3900 3730 3820 Water added at site: 15 gallons. Notified contractor about excessive sltunp. FRACTURE TYPE Unbonded Cap Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed andpage 1 of 3reproduced except in full without the written approval of Rone Engineers, L[d. O1 Report No.: 192365 Project No.: 037748 Client: Purple Mountain Construction Services RoneEngineers F~® ***REVISED 9/9/03 to reflect correct compressive strength*** LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are For the exclusive use of the clients to wham they are addressed and shall no[ be reproduced except in full without the written approval of Rone Engineers, Ltd. Ol Page 2 of 3 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 Ro n e E n g n ee rs 6300 Aothway, Ste. 150, Houston, TX 77040 Corporate Pbone: (214) 630-9745 - CONCRETE COMPRESSIVE STRENGTH TE5T Client: Pttrple Mountain Construction Services Attn: Mr. Jeff Burkham 4712 Memphis St. Dallas TX 75207 Project: Deliman Grill 605 N. Denton Tap Road Coppell, TX Report No.: 192365 Project No.: 037748 Date of Service: 08/08/2003 Report Date: 09/08/2003 Services: Obtain samples of fresh concrete at the placement locations, perfomt required field testing, cast compressive strength samples and bring samples back to [he laboratory for curing and testing in accordance with applicable standards. PROJECT DATA coNTRACroR: Purple Mountain Constmction MIX DESIGN [.D.: 7752 CONCRETE SUPPLIER: HanSOn PLACEMENT DATE: OH/O8/2003 PLANT: 27 WEATHER CONDITIONS: CIOUdy SPECIFICATION REQUIREMENTS TIME SAMPLED: 9:28am BATCH TIME: 9:00 am STRENGTH: 3000 pSl @ 2S DayS TEMPERATURE (F) -AIR 91 F CONCRETE: 96 F SLUMP (in): S" maXlmDln TRUCK NO: 1815 TICKET NO: 402291 AIR (% ): 4.S% - ZS% AIR CONTENT (%): 3.8 UNIT WEIGHT (pcQ: NA OVERALL PLACEMENT LOCATION: TEST METHOD: ASTM C-172 paving area from northeast building comer northward to existing pavemrnt of adjacent ASTM C-31 parking lot and west to expansion joint north of building exit door (approximately middle of ASTM C-143 north welt). ASTM C-231 ASTM C-1064 SAMPLE LOCATION: 20' south ofjoint to existing con- ASTM C-138 Crete of adjacent parking lot. ASTM C-39 UFPn72T nF TFCTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MARKED SET NO. 2 1 2 2 2 3 2 4 MEASURED SLUMP (inches) 6.S 6.S 6.5 6.S DATE TESTED 08/11/2003 08/1S/2003 09/05/2003 09/OS/2003 Water added at site: 5 gallons. Notified contractor about excessive sltunp. AGE (days) 3 7 28 28 MAXIMUM COMPRESSIVE LOAD STRENGTH (Ibs. force) (Psi) 80855 2860 97175 3440 Technician: Jason Creasy Started: 4:30 am Finished: 11:3 Report Distribution: (I) Purple Mountain Construction Services FRACTURE TYPE Unbonded Cap Unbonded Cap LEvIITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assmne no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. 01 Page 3 of 3 117175 4140 Unbonded Cap 11S30S 4080 Unbonded Cap Average 4110