CONCRETE COMPRESSIVE STRENGTH TEST
Client: Purple Mountain Construction Services Report No.: 190119
Attn: Mr. Jeff Btuidtam Project No.: 037748
4712 Memphis St. Date of Service: 07/02/2003
Dallas TX 75207 Report Date: 08/28/2003
Project: Deliman Carill
605 N. Denton Tap Road
Coppell, TX
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
coNTRACTOR: Purple Mountain Construction mIx DESIGN I.D.: 9325
CONCRETE SUPPLIER: HanSOn PLACEMENT DATE: O7/O2/2003
29 WEATHER CONDITIONS: Clear
PLANT: TIME SAMPLED: 12:3Opm BATCH TIME: 11:2$am
SPECIFICATION REQUIREMENTS
STRENGTH: 3000 pSl @ 28 Days TEMPERATURE(-AIR 9O F CONCRETE: 96 F
S ° - 7" TRUCK NO: 1 OO TICxET No: 349309
SLUMP (in): NA AIR CONTENT (%): 1.7 UNIT WEIGHT (pcf): NA
AIR (% ): OVERALL PLACEMENT LOCATION:
TEST METHOD: ASTM C-172 Piers at E/3, E/5, E/2, B/1, C/1, D/1
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064 SAMPLE LOCATION: Pier at E/3, cylinder 1-5, 1-6, 1-7
ASTM C-138 taken from pier B/1
ASTM C-39 RFPnR T nF TF4TS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. inJ
CYLINDER MEASURED MAXIMUM
LOAD COMPRESSIVE
STRENGTH
PRACTURE
MAREED SLUMP DATE
TESTED AGE
(days) pba. force) (psi) TYPE
SET NO. (inches)
1 4
5 07/09/2003 7 76030 2690 Unbonded Cap
1 .
1 2 4
5 07/30/2003 28 102875 3640 Unbonded Cap
1 3 .
4.5 07/30/2003 28 102415 3620 Unbonded Cap
Average 3630
1 4 Hold
1 5 4.5 07/05/2003 3 71835 2540 Unbonded Cap
LIMITATIONS: The test results presrn[ed herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DD Page 1 of 2
Report No.: 190119
Project Na.: 037748 Client: Purple Mountain Construction Services
RoneEngineers
CYLINDER MEASURED
MARKED SLUMP DATE
SET NO. (Inches) TESTED
1 6 4.5 07/09/2003
1 7 4.5 07/30/2003
See report #190118 for technician time
Techntcian: Shawn Deal Started:
Report Distribution:
(1) Purple Mountain Constmction Services
MAXIMf1M COMPRESSIVE
AGE LOAD STRENGTH FRACTURE
(days) (Ibs. force) (psi) TYPE
7 78410 2770 Unbonded Cap
28 101345 3580 „ Unbot~ Cap
Finished:
Rone
Project
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DD Page 2 of 2
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Port Worth, TX 76118
~o n e E n g i n ee rs 6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client: Purple Mountain Construction Services
Attn: Mr. Jeff Burkham
4712 Memphis St.
Dallas TX 75207
Project: Deliman Grill
605 N. Denton Tap Road
Coppell, TX
Report No.: 192844
Project No.: 037748
Date of Service: 08/20/2003
Report Date: 08/28/2003
Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
CONTRACTOR: Purple MDimtaln CDn$tructiDn MIX DESIGN LD.: 7752
CONCRETE SUPPLIER: HanSOn PLACEMENT DATE: OS/2O/2003
NA WEATHER CONDITIONS: Clcar
PLANT: TIME SAMPLED: 7:SOam BATCH TIME: 6:S7am
SPECIFICATION REQUIREMENTS 92 F
STRENGTH: 3000 pSl t/Q 28 Days TEMPERATURE ([>) -AIR $4 F CONCRETE:
3° - S° TRUCK NO: 823 T[CKET NO: 488260
SLUMP (in): o o
-S/o
3/ AIR CONTENT (%>: 4.3 UN[T WEIGHT (pct): NA
AIR (%): o OVERALL PLACEMENT LOCATION:
TEST METHOD: ASTM C-172 Paving, south drive from southwest building comer to drive thm window
ASTM C-31
ASTM C-143
ASTM C-231
ASTM C-1064 SAMPLE LOCATION: 15' south, ]0' east of southwest
ASTM C-138 building comer
ASTM C-39 UFPnR T nF TF.CTC
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. inJ
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH PRACTURE
SET NO. (inches) TESTED (days) pbs. farce) (psi) TYPE
1 I 4.5 08/27/2003 7 98370 3480 Unbonded Cap
1 2 4.S 09/17/2003 28 Unbonded Cap
1 3 4.5 09/17/2003 28 Unbonded Cap
1 4 4.S 10/1S/2003 56 Unbonded Cap
Technician: ]tick Smith Started: 7:OOam Pinisnea: 8:4Sam ~/\~ `~R~one Engineers, Ltd.
~
Report Distribution: \\
'
' 1'~"~~(
(1) Purple Mountain Consnuction Services ----
= ~~~
Clay Stark
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other Feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
O1DD Page 1 of 1
8908 Ambassador Row, Dallas, TX 75247
Ro n e E n g i n ee rs 2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, S[e. 150, Houston, TX 77040
- Corporate Phone: (214) 630-9745
CONCRETE COMPRESSIVE STRENGTH TEST
Client: Purple Molmtain Construction Services
Atm: Mr. Jeff Burldlam
4712 Memphis St.
Dallas TX 75207
Report No.: 191565
Project No.: 037748
Date of Service: 07/29/2003
Report Date: 08/27/2003
Project: Deliman Grill
605 N. Denton Tap Road
Coppell, TX
SerVleeS: Obtain samples of fresh concrete a[ the placement locations, perform required field testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in aceordance with applicable standards.
PROJECT DATA
coNTRACroR: Purple Mountain Construction MIX DESIGN I.D.: 9337
CONCRETE SUPPLIER: HanSOn _ PLACEMENT DATE: 07/29/2003
PLANT: 27 WEATHER CONDITIONS: Clear
SPECIFICATION REQUIREMENTS TIME SAMPLED: 6:4Oam BATCH TIME: 6:OOam
STRENGTH: 3000 pSl @ 28 Days TEMPERATURE (F) -AIR 7$ F CONCRETE: 94 F
SLUMP (in): NA TRUCK NO: 1045 TICKET NO: 402096
AIR (•~ ): NA AIR CONTENT (%): O.9 UNIT WEIGHT (pct): NA
TEST METHOD: AS~hM C-172 OVERALL PLACEMENT LOCATION:
Entire slab, including all interior grade beams and top of ex[edor grade beams
A$TM C-31
ASTM C-143
AST'M C-231
AST'M C-1064
SAMPLE LOCATION: Lines B/4
A$TM C-13$
ASTM C-39 RFPOR T OF TESTS
Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.)
CYLINDER MEASURED MAXIMUM COMPRESSIVE
MARKED SLUMP DATE AGE LOAD STRENGTH FRACTURE
SET NO. (inches) TESTED (days) (Ibs. force) (psi) TYPE
1 1 10.5 08/01/2003 3 56660 2000 Unbonded Cap
1 2 10.5 08/05/2003 7 64895 2290 Unbonded Cap
1 3 10.5 08/26/2003 28 84690 2990 * Unbonded Cap
1 4 10.5 08/26/2003 28 80785 2860 * Unbonded Cap
Average 2930
1 5 10.5 09/23/2003 56 Unbonded Cap
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in qualiTy
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients [o whom [hey are addressed and shall not be reproduced except in full without [he written approval of Aone Engineers, Ltd.
O1DD Page 1 of 2
Report No.: 191565 RO®qln
Project No.: 037748 Client: Purple Mountain Constmction Services ai
* Does not comply with specified strength.
Specified air content and slump could not be found in plans or specification book
or on site.
Notified contractor about excessive slump.
Concrete mixer driver did not know amount of water adder
Technician: Jason Creasy Started: 6:OOam Finished: 9:OC
Report Distribution:
(1) Purple Mountain Construction Services
LIMITATIONS: The test results presented herein were prepareA based upon the specific samples provided for testing. We assume nc responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for [he exclusive use of the clients to whom they are addressed and shall no[ be reproduced except in Cull without the written approval of Roae Engineers, Ltd.
OtDD Page 2 of 2