Magnolia Rest-LR030801 gineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76110
6300 Rothway, Ste. 150, Houston, TX 77040
Coeporate Phone: (214) 630-9745
REPORT OF REINFORCING STEEL INSPECTION
Client:
Purple Mountain Construction Services
Arm: Mr. Jeff Burkham
4712 Memphis St.
Dallas TX 75207
Project: Deliman Grill
605 N. Denton Tap Road
Coppell, TX
Services: Reinforcing Steel Inspection
Report No.: 191521
Project No.: 037748
Date of Service: 07/28/2003
Report Date: 08/01/2003
Report of Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform Reinforcing Steel Inspection. The results are attached.
Technician Time:
Page 1 of 2
Technician: Jason Creasy
Report Distribution:
(1) Purple Mountain Construction Services
2:00pm - 5:00pm
, S~k
Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no msponsibilily for vafiation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the wrlttea approval of Rone Engineers, LM.
99DD PaRe 1 of I
RoneEn gineers
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
121 North Rayner
Fort Worth, Texas 76111
(817) 831-6211
Report of
Reinforcing Steel Inspection
Client: ~ ~-~ t/io ,~--~., / / ReportNo.:
Project: ~L~ ~ z~;( ":~ (.~ ~ Date of Se~ice:
' '"i ' ~ 7'- 2~ .-.o ~'
Page
/ of /
Locations and Items Inspected:
?lacing Drawings ~ Bar Length V//( Cotumn Ties Properly
3ar Size ~ Proper Bar PI ..... t ~/ Stirrup Spacing and Type
3ar Grade .~" Properly Tied X Lapped Splices
?orm Clean X Proper Bar Supports ~ Mechanical Splices
NumBer Bars ~ Proper Cover ~
Discrepancies / Comments:
I nspectorsS~gna~re: ~~~ ~. . _ .~ Time: to
Client/Contractor Si~ature~ ~ ~ ClienffCon~actor Copied with Results~H¢~/~ No
RoneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630~9745
REPORT OF REINFORCING STEEL INSPECTION
CHent:
Purple Mountain Construction Services
Atto: Mr. JeffBurkham
4712 Memphis St.
Dallas TX 75207
Report No.: 191564
Project No.: 037748
Date of Service: 07/29/2003
Report Date: 08/01/2003
Project:
Services:
Deliman Grill
605 N. Denton Tap Road
Coppell, TX
Reinforcing Steel Inspection
Report of Inspection
On this date, a Rone Engineers, Ltd. representative(s) arrived on site as
scheduled to perform Reinforcing Steel Inspection. The results are attached.
Technician Time:
Page 1 of 2
Technician: Jason Creasy
Report Distribution:
(1) Purple Mountain Construction Services
4:30am - 6:00am
Project Manager
LIMiTATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, perfonnance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd.
99DD Pace 1 of 1
8908 Ambassador Row
Dallas, Texas 75247
(214) 630-9745
121 North Rayner
Fo~t Worth, Texas 76111
(817) 831-6211
Client:
Project:
Report of
Reinforcing Steel Inspection
/¢7~A/7~/C/A/ Report No.:
Project No.:
~IL/_- Date of Service:
Page
/ of /
Locations and Items Inspected:
Items Inspected: Conforming Non Items Inspected: Conforming Non Items Inspected: Conforming Non
/ Conforming Conforming Conforming
Placing Drawings ~//e/ Bar Length ~r Eolumn Ties Properly
Approved and Shape tied and Spaced
Bar Size W'/F. Proper Bar Placement V[ Stirrup Spacing and Type ~/
Bar Grade ~ Properly Tied X Lapped Splices ~
Bars Clean ~ Dowel Bars in Place , Welded Splices
Foma Clean ~ ?roper Bar Supports ~c~ ~ ~ Mechanical Splices
Number Bars V/' ~ ,_--~ Proper Cover ~ ~r~ ~ ~
Discrepancies / Comments:
,nJ;~tor's ~ignamre: ~~{~' Time:
r / aien Con ac °rCopiedwi h ¢ t o
ClienffContractor Signatu ~: :_,
RoneEn g
Client:
Purple Mountain Construction Services
Arm: Mr. JeffBurldmm
4712 Memphis St.
Dallas TX 75207
Project: Deliman Grill
605 N. Denton Tap Road
Coppell, TX
Services: Cylinder Collection
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150, Houston, TX 77040
Corporate Phone: (214) 630-9745
REPORT OF CYLINDER COLLECTION
Report No.: 191623
Project No.: 037748
Date of Service: 07/30/2003
Report Date: 08/01/2003
Report of Collection
On this date, a Rone Engineers, Ltd. representative arrived on site as scheduled
to pick up compressive strength test specimen cast prior to this date.
Technician Time: 8:45 AM - 10:00 AM
Page 1 of 1
Technician: Jason Creasy
Report Distribution:
(1) Purple Mountain Construction Services
Pf'ayj ectIdanager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be ~.produced except in full without the written approval of Rone Engineers, Ltd.
99DF Page 1 of I