Loading...
Magnolia Rest-LR030604RoneEn gineers 8908Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150, Houston, TX 77040 Corporate Phone: (214) 630-9745 REPORT OF WATER INJECTION INSPECTION Client: Purple Mountain Construction Services Attn: Mr. JetTBur!oham 4712 Memphis St. Dallas TX 75207 Report No.: 177321 Project No.: 037748 Date of Service: 05/27/2003 Report Date: 06/04/2003 Project: Services: Deliman Grill 605 N. Denton Tap Road Coppell, TX Water Injection Inspection Report of Inspection On this date, a Rone Engineers, Ltd. representative(s) was on site to perform Water Injection Inspection. The results are attached. Technician Time: 7:00 a.m. Page 1 of 3 Technician: Rormie Jenkins Report Distribution: (1) Purple Mountain Construction Services - 11:30 a.m. Rone Ltd. Stark LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mat/er provided by persons or conditions over which we have no control. Our letters and repons are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in fall without the wriaen approval of Rone Engineers, Ltd. 99DD Page I of 1 WATER INJECTION OBSERVATION Client: Project: Purple Mountain Construction Services Deliman Grill 605 N. Denton Tap Road Report No.: 177321 Project No.: 037748 Date of Service: 5/27/2003 Page 2 of 3 Coppell, TX DESCRIPTION/EXPLANATION YES NO N/A 1. specific gravity of lime was checked and found to be 1.14 and 1.17 X 2. Lime slurr~ was continuously a~litated X 3. Surfactant was added to each load X 3. The iniection pressure was kept between 50 to 100 psi at point of iniection X 5. Intervals of 12" were achieved durin~l iniection process until refusal X 5. Total depth of iniection -- 10 feet X ~'. Max. spacin~ of injection probes was recorded to be 5 ft. X 3. Free lime on surface X 9. Square feet iniected on this date 3,600 sq ft 10. Location of iniection Buildin~ pad Remarks: Injector did not use surfactant. See attached for sketch of injected area, pass number for each area and dimension of injection area. Time: Technician: 7:00 a.m. - 11:30 a.m. Ronnie Jenkins LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for vadaflon in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and repor[s ars for the exclusive use of the clients to whom they are addressed and shall not be reproduced except Jn full without the wdtten approval of Rone Engineers, Ltd.