Magnolia Rest-LR030603RoneEngineers
8908 Ambassador Row, Dallas, TX 75247
2696 Gravel Drive, Fort Worth, TX 76118
6300 Rothway, Ste. 150. Houston, TX 77040
Corporate Phone: (214) 630-9745
REPORT OF WATER INJECTION INSPECTION
Client:
Purple Mountain Construction Services
Attn: Mr. JeffBurkham
4712 Memphis St.
Dallas TX 75207
Report No.: 177242
Project No.: 037748
Date of Service: 05/23/2003
Report Date: 06/03/2003
Project:
Services:
Deliman Grill
605 N. Denton Tap Road
Coppell, TX
Water Injection Inspection
Report of Inspection
On this date, a Rone Engineers, Ltd. representative(s) was on site to perform
Water Injection Inspection. The results are attached.
Technician Time: 7:00 a.m.
Page 1 of 3
Technician: Rormie Jenkins
Report Distribution:
(i) Purple Mountain Construction S~rvices
- 1:00 p.m.
"~ Stark
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and
reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the writren appmvaI of Rone Engineers, Ltd.
99DD Pa~e 1 of 1
WATER
INJECTION OBSERVATION
Client:
Project:
Purple Mountain Construction Services
Deliman Grill
605 N. Denton Tap Road
Report No.: 177242
Project No.: 037748
Date of Service: 5/23/2003
Page 2 of 3
Coppell, TX
DESCRIPTION/EXPLANATION YES NO N/A
1. Specific ~ravit)/of lime was checked and found to be 1.14 and 1.17 x
2. Lime slurq/was continuously a~itated X
3. Surfactant was added to each load X
¢. The iniection pressure was kept between 50 to 100 psi at point of injection x
5. Intervals of 12" were achieved durin~l iniection process until refusal x
3. Total depth of injection -- 10 feet x
?. Max. spacing of iniection probes was recorded to be 5 ft. x
3. Free lime on surface X
,~. Square feet iniected on this date 3,600.0 sq. ft.
10, Location of injection Buildin~ Pad
Remarks: No surfactant was added due to the depletion of the on site supply.
See attached for sketch of injected area, pass number for each area and dimension of injection area.
Time:
Technician:
7:00 a.m. - 1:00 p.m.
Ronnie Jenkins
LIMITATIONS: The test results presented heroin were prepared based upon the specific samples provided for testing. We assume no responsibility for
variation in quality (composition, appearance, pen~ormance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we
have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without
the written approval of Rone Engineers, Ltd.
B~-~ -o3