Loading...
Magnolia Rest-LR030603RoneEngineers 8908 Ambassador Row, Dallas, TX 75247 2696 Gravel Drive, Fort Worth, TX 76118 6300 Rothway, Ste. 150. Houston, TX 77040 Corporate Phone: (214) 630-9745 REPORT OF WATER INJECTION INSPECTION Client: Purple Mountain Construction Services Attn: Mr. JeffBurkham 4712 Memphis St. Dallas TX 75207 Report No.: 177242 Project No.: 037748 Date of Service: 05/23/2003 Report Date: 06/03/2003 Project: Services: Deliman Grill 605 N. Denton Tap Road Coppell, TX Water Injection Inspection Report of Inspection On this date, a Rone Engineers, Ltd. representative(s) was on site to perform Water Injection Inspection. The results are attached. Technician Time: 7:00 a.m. Page 1 of 3 Technician: Rormie Jenkins Report Distribution: (i) Purple Mountain Construction S~rvices - 1:00 p.m. "~ Stark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the writren appmvaI of Rone Engineers, Ltd. 99DD Pa~e 1 of 1 WATER INJECTION OBSERVATION Client: Project: Purple Mountain Construction Services Deliman Grill 605 N. Denton Tap Road Report No.: 177242 Project No.: 037748 Date of Service: 5/23/2003 Page 2 of 3 Coppell, TX DESCRIPTION/EXPLANATION YES NO N/A 1. Specific ~ravit)/of lime was checked and found to be 1.14 and 1.17 x 2. Lime slurq/was continuously a~itated X 3. Surfactant was added to each load X ¢. The iniection pressure was kept between 50 to 100 psi at point of injection x 5. Intervals of 12" were achieved durin~l iniection process until refusal x 3. Total depth of injection -- 10 feet x ?. Max. spacing of iniection probes was recorded to be 5 ft. x 3. Free lime on surface X ,~. Square feet iniected on this date 3,600.0 sq. ft. 10, Location of injection Buildin~ Pad Remarks: No surfactant was added due to the depletion of the on site supply. See attached for sketch of injected area, pass number for each area and dimension of injection area. Time: Technician: 7:00 a.m. - 1:00 p.m. Ronnie Jenkins LIMITATIONS: The test results presented heroin were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, pen~ormance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Ltd. B~-~ -o3