Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Bank One-LR031117
CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0071 Service Date: October 20, 2003 'lrerracan 8901 Carpenter Fn~y, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: November 17, 2003 Project: Bank One - Coppell TX 616 Nodh Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 9:47am Supplier: TXI Truck No: 71 Mix i.D. No.: 8274 Plant: 41 Field Test Data Test Ticket No: 3423761 Sample Information sample Time: 10:30am Date Cast: October 20, 2003 Technician: Melvin L. Searles Weather Conditions: Clear & hot Accumulative Yards: 5 Placement Method: Diect Discharge Sample Locations: See placement location Placement Location: Southeast approach & sidewalk area Result Specification Test Method Slump, inches: 3.00 ASTM C-143 Air Content, %: 3.0 ASTM C-231 Concrete Temperature, o F: 85 ASTM C-1064 Ambient Temperature,© F: 77 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 10~27~2003 7 115,590 4,090 1 2 6.00 28.27 10/27/2003 7 122,890 4,350 Average 4,220 1 3 6.00 28.27 11/17/2003 28 149,220 5,280 I 4 6.00 28.27 11/17/2003 28 151,660 5,360 Average 5,320 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, ped'orm required field tests and cast compressive strength samples. Technician: Melvin L. Searles Report Distribution: (1) Bank One Texas NA (1) City of Coppe~l TX (1) Aguirre BuiMing Systems (1) City of Coppetl TX Reviewed by: ~con Hus§ei~ H. Abusaad, PE Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are onty applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials