Loading...
Bank One-LR031113CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0068 Service Date: October 15, 2003 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 'lrerracan 6901 Carpenter Frw¥, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: November 13, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: Supplier: LDJ Truck No: Ticket No: 51185 Mix I.D. No.: 60A Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 5.25 Air Content, %: 3.4 Concrete Temperature, o F: 84 Ambient Temperature, o F: 78 Plastic Unit Weight, pcf: Laboratorv Test Data Sample Information Sample Time: 4:07pm Date Cast: October 15, 2003 Technician: ThomasB. Combs Weather Conditions: Sunny Accumulative Yards: 20 Placement Method: Direct Discharge Sample Locations: 45' N of SE approach Placement Location: Parking Lot Specification Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 10/22/2003 7 86,200 3,050 1 2 6.00 28.27 10/22/2003 7 88,650 3,130 Average 3,090 1 3 6.00 28.27 11/12/2003 28 126,150 4,460 1 4 6.00 28.27 11/12/2003 28 123,340 4,360 Average 4,410 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Thomas B. Combs Repod Distribution: (1) Bank One Texas NA (1) City of Coppeil TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: Hussein H. Abusaad, P.E Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical