Bank One-LR031103CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0074 Service Date: October 27, 2003 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: November 03, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 9:37am Plant: 41 Supplier: TXI Truck No: 716 Ticket No: 3428920 Mix I.D. No.: 8274 Water Added Onsite Before Test: 15 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 4.00 Air Content, %: 48 Concrete Temperature,° F: 76 Ambient Temperature, o F: 57 Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 10:30am Date Cast: October 27, 2003 Technician: Michael W. Whyman Weather Conditions: Clear Accumulative Yards: 5 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: For brick fill ~ Denton Tap Road entrance Specification Test Method ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/03/2003 7 120,370 4,260 1 2 6.00 28.27 11/03/2003 7 110,110 3,890 Average 4,080 1 3 11/24/2003 28 1 4 11/24/2003 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Michael W. Whyman Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: Hu.~sein H. Abusaad, PE. Senior Project Manager The tests were performed in general accordance with app{icable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar er identical