Loading...
Bank One-LR031028CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0061 Service Date: September 27, 2003 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: October 28, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 6:12am Plant: 2 Supplier: LDJ Truck No: 724 Mix I.D. No.: 50A Water Added Onsite Before Test: Field Test Data Test Result Slump, inches: 5.75 Air Content, %: 5.1 Concrete Temperature, o F: 85 Ambient Temperature, o F: 73 Plastic Unit Weight, pcf: Laboratorv Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) Ticket No: 35486 5 Gallons Sample Information Sample Time: 7:30am Technician: Tom Cleaver Weather Conditions: Cloudy Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See attached sketch Placement Location: Approach S of bank Specification Test Method Date Cast: September 27, 2003 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 1 1 6.00 28.27 10/04/2003 7 76,280 2,700 1 2 6.00 28.27 10/04/2003 7 74,210 2,620 Average 2,660 1 3 6.00 28.27 10/25/2003 28 106,810 3,780 1 4 6.00 28.27 10/25/2003 28 103,020 3,640 Average 3,710 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Tom Cleaver Report Distribution: (1) Bank One Texas NA (1) City of Coppell TX (1) Agume Building Systems (~) City of Coppek TX Reviewed by: HBC/Terracon Hussein H Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 1 l'erracan Consulting Engineers & Scientists CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94031289.0071 Service Date: October 20, 2003 'lFerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Bank One Texas NA Attn: Danny Buckner 8111 Preston Suite 250 Dallas TX 75225 Report Date: October 28, 2003 Project: Bank One - Coppell TX 616 North Denton Tap Rd Coppell, TX Project Number: 94031289 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:47am Supplier: TXI Truck No: 71 Mix I.D. No.: 8274 Plant: 41 Field Test Data Test Ticket No: 3423761 Sample Information Sample Time: 10:30am Date Cast: October 20, 2003 Technician: Melvin L. Seades Weather Conditions: Clear & hot Accumulative Yards: 5 Placement Method: Diect Discharge Sample Locations: See placement location Placement Location: Southeast approach & sidewalk area Result Specification Test Method Slump, inches: 3.00 ASTM C-143 Air Content, %: 3.0 ASTM C-231 Concrete Temperature,o F: 85 ASTM C-1064 Ambient Temperature, o F: 77 ASTM C-1064 Plastic Unit Weight, pcf: Laborator}/ Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No, ID (inches) (sq. inches) Tested (days) (lbs) (psi) I 1 600 28.27 10/27/2003 7 115,590 4,090 1 2 6.00 28.27 10/27/2003 7 122,890 4,350 Average 4,220 1 3 11/17/2003 28 1 4 11/17/2003 28 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Melvin L. Searles Report Distribution: (1) Bank One Texas NA (1) City o[ Coppell TX (1) Aguirre Building Systems (1) City of Coppell TX Reviewed by: HBC/Terracon Hussei~ I~. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods This report is exc[usively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon Test results transmitted herein are only applicable to the actual samples tested at the location(s) reCerenced and are not necessarily indicative ol the properties of other apparently similar or identical materials